Fitting Instructions and User Guide

 

B3/C3 M RANGE 

Содержание B3 M

Страница 1: ...Fitting Instructions and User Guide B3 C3 M RANGE...

Страница 2: ...3 0 INSTALLATION 5 4 0 COMMISSIONING 11 5 0 EXPLANATION TO USER 12 6 0 MAINTENANCE 14 7 0 FAULT FINDING 15 8 0 SPARE PARTS 16 9 0 ACCESSORIES 16 10 0 GUARANTEE 17 11 0 ENVIRONMENTAL INFORMATION 17 12...

Страница 3: ...f they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user mainten...

Страница 4: ...be arranged to discharge into the cold water feed cistern The vent pipe must have a minimum bore of 19mm More than one conventional tap can be supplied 1 2 PACK CONTENTS Before commencing installation...

Страница 5: ...water below the surface of the wall 5 DO NOT install where the unit may freeze 6 Refer to the section IMPORTANT INSTALLATION POINTS to determine which valves and accessories are required 7 The water c...

Страница 6: ...e pads of the Levelling Feet and affix them to the lower back of the unit in the approximate positions shown on Figure 2 4 Hang the unit on the wall mounting bracket ensuring the location bolt locates...

Страница 7: ...ure of 0 4 bar 4 metres head A drain cock should be incorporated in the supply to facilitate draining the heater for maintenance 5 The inlet tap should be fitted to the INLET pipe of the heater The in...

Страница 8: ...nt pipe of this water heater 5 The cold water supply must be from a cold water feed cistern complying with Byelaw 30 The maximum head pressure must not exceed 20 metres 6 It is recomended that an WRC...

Страница 9: ...9 FIGURE 04 TYPICAL CISTERN FED INSTALLATION DRAIN COCK VENT PIPE CISTERN TANK ISOLATING VALVE B3 C3 M HEATER...

Страница 10: ...with a 1 0m 3 core 1 5mm2 flexible cable The electicity supply should be fused 13 Amp for a 3kW model and be via a double pole isolating switch with a contact separation of at least 3mm in both poles...

Страница 11: ...or 4 2 4 below Always switch off the electrical supply before removing the terminal cover 3 Setting the mid range position Rotate the thermostat knob to the mid position Remove the terminal cover by...

Страница 12: ...not the system pipework 4 Show how the thermostat can be locked in either the mid range or hot position and recommend that this procedure is carried out by a qualified electrician 5 Show that the ind...

Страница 13: ...Sadia The outlet of the tap must not be restricted or blocked in any way In an Open Outlet installation it is normal for the hot outlet to drip during heating This is due to the expansion of water as...

Страница 14: ...ning the drain cock in the inlet pipework 3 Remove the terminal cover by using a large flat bladed screwdriver to depress the 4 snap lugs located in the 4 rectangular depressions on the bottom cover 4...

Страница 15: ...lace if necessary Element fault Check element for circuit continuity and insulation resistance If faulty replace No water flow General Cold water supply not turned on Check mains water supply is on Bl...

Страница 16: ...5 607 996 Spout and adaptor 95 604 212 9 0 ACCESSORIES The heater can be used to supply only one outlet when used in an open outlet installation More outlets can be supplied in a cystern fed installat...

Страница 17: ...ot guaranteed against excessive scale build up This guarantee does not affect the statutory rights of the consumer 11 0 ENVIRONMENTAL INFORMATION The Waste Electrical and Electronic Equipment Producer...

Страница 18: ...__ Installer Electrical ________________________________________ Contact Details ____________________________________________ Competency Scheme ID Number _________________________ Comments ___________...

Страница 19: ...___________ ________________________________________________ ________________________________________________ Service Date _______________________________________________ Engineer ____________________...

Страница 20: ...Newey Eyre Unit 3 5 Wassage Way Hampton Lovett Ind Estate Droitwich Worcestershire WR9 0NX Tel 01905 791500 Fax 01905 791501 UK Spares Ltd Unit 1155 Aztec West Almondsbury Bristol BS32 4TF Tel 01454...