8 USER INFORMATION

8.1 To turn on and set temperature:

1. Turn on your isolating switch.
2. Press the ‘START/STOP’ button.  The

water will flow and the elements set
to the power setting last used.   The
‘START/STOP’ and power setting
indicators will light.  The shower can
also be turned on by pressing one of
the power setting buttons.

3. Allow the shower approximately 30

seconds to heat up and check the
water temperature with your hand.
Adjust as necessary by turning the
water control knob.

WARMER 

- DECREASE FLOW - TURN

KNOB CLOCKWISE

COOLER

 - INCREASE FLOW - TURN

KNOB ANTI-CLOCKWISE

SETTING DESCALE TIMER TO

ZERO

5:55

Carry out the following procedure to

stop the ‘Inspect Handset’ light flashing.

The descale timer can only be set to zero
when the ‘INSPECT HANDSET’ light is
flashing.

5.56

Hold down the ‘START/STOP’ button

and then momentarily press the ‘LOW’
button.  The descale time will then be set
to zero and the ‘INSPECT HANDSET’ light
will stop flashing.

5.57

The shower will continue to function

even when the ‘INSPECT HANDSET’ light
is flashing.  The system is simply a helpful
reminder that the shower head may
require descaling.

GUARANTEE & SERVICE POLICY

This product is guaranteed against faulty
materials and manufacture for a period of
2 years from the date of purchase
provided that:-

6.1

The unit has been installed in

accordance with the Installation and User
Instructions and all relevant Codes of
Practice and Regulations in force at the
time of installation and that all necessary
controls and safety valves have been fitted
correctly.

6.2

Any valves and controls are of

Heatrae Sadia recommended type and
specification.

6.3

The unit has not been modified or

tampered with in any way and has been
regularly maintained as detailed in the
Installation and User Instructions.

6.4

The unit has been used only for

heating potable water.

The unit is not guaranteed against
damage by frost and the inner container
with integral heating element is not
guaranteed against excessive scale build-
up.

This guarantee in no way affects the
statutory rights of the consumer.

The policy of Heatrae Sadia is one of
continuous product development and, as
such, we reserve the right to change
specifications without notice.

ENVIRONMENTAL INFORMATION

Heatrae Sadia products are manufactured
from many recyclable materials.  At the
end of their useful life they should be
disposed of at a Local Authority Recycling
Centre in order to realise the full
environmental benefits.

7

2. Fit a double-check valve in the

pipework to the shower.

3.9

Decide from which direction your inlet

pipe will enter the shower heater.  There
is a choice of entry from top, bottom, right
hand side or rear - see Fig. 9.

3.10

Ensure there are no services such

as gas, water pipes, electrical or telephone
cables beneath the surface of the wall
before drilling.

3.11

The water connection to the shower

heater should be made using standard
15mm outside diameter copper pipe or a
stainless steel pipe.  The ends of the pipe
should be cut square and be free from
internal and external burrs and deep
scratches.

3.12

Cut all necessary pipework to length

with a pipe cutter and not a hacksaw, to
minimise swarf - see Fig. 5.

3.13

Before making the final water

connections to the shower heater, the
pipework MUST BE FLUSHED
THOROUGHLY to remove brick dust,
swarf etc. which could severely damage
the shower itself - see Fig. 6.

3.14

A Water Regulations Advisory

Service listed servicing valve should be
fitted in the water supply pipe to the
shower.  This is to allow the shower heater
to be serviced without turning off the water
supply to other appliances.

THINGS YOU MUST NOT DO

3.15

DO NOT use plumber’s paste on any

joints as this may damage the shower.

3.16

DO NOT use a blow-torch or other

form of heat close to the shower heater
as this may damage the non-metallic
parts.

3.17

DO NOT use excessive force, but do

ensure adequate support, when making
connections.

Figure 5  Cutting pipes

Figure 6  Flushing the pipework

Содержание Accolade

Страница 1: ...0 Chantry Gate Business Centre Springfield Road Hayes Middlesex Tel 020 8573 0574 Parts Center Network 65 Business Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co...

Страница 2: ...ected to the protected neutral bar of the unit A Descale handset as described in 8 5 Reset the timer as described in 5 56 POSSIBLE CAUSE A Cartridge fuse or miniature circuit breaker mcb has operated...

Страница 3: ...d be careful not to turn water control knob too far anticlockwise Reset as in A A Increase the flow by turning the water control knob anticlockwise Clean the handset and sprayplate B Ensure that your...

Страница 4: ...ion 2 11 The shower heater outlet hose and handset act as a vent They must not be blocked obstructed or have connected to them any fitting not approved by the manufacturers The use of unapproved acces...

Страница 5: ...not be covered by the guarantee WARNING If you suspect your shower is frozen DO NOT SWITCH ON If you have switched on SWITCH OFF IMMEDIATELY Refer to Fault Finding p17 2 14 Do not leave the infirm di...

Страница 6: ...If the handset can reach to within 25mm 1 of the spillover level of the bath shower tray wash basin WC or bidet then to prevent the possibility of back siphonage of used water Water Regulations Guide...

Страница 7: ...by frost and the inner container with integral heating element is not guaranteed against excessive scale build up This guarantee in no way affects the statutory rights of the consumer The policy of He...

Страница 8: ...water to be flushed from the can When flow stops turn off the isolating switch USER PROTECT SYSTEM 5 50 The User Protect system is intended to prevent showering temperatures reaching harmful levels To...

Страница 9: ...e Continue to turn the water control knob clockwise the flow will reduce and the LOW FLOW light will flash Turn the water control knob anticlockwise until the LOW FLOW light goes OFF and the temperatu...

Страница 10: ...have been made 5 19 Carry out any cutting with pipe cutters in preference to a hacksaw to minimise swarf Use 15mm compression fittings preferably with copper compression rings olives for the connecti...

Отзывы: