Heatrae Sadia 10 Litre 1kW Скачать руководство пользователя страница 2

2

CONTENTS

SECTION 

      PAGE

1.0 

INTRODUCTION 

     3

2.0 

TECHNICAL 

SPECIFICATIONS 

   4

3.0 

INSTALLATION 

     6

4.0 

COMMISSIONING 

     10

5.0 

EXPLANATION 

TO 

USER 

    11

6.0 

MAINTENANCE 

     12

 

7.0 

FAULT 

FINDING 

     14

8.0 

SPARE 

PARTS 

     15

9.0 

GUARANTEE 

     17

10.0 

ENVIRONMENTAL 

INFORMATION 

   17

11.0 

COMMISSIONING 

RECORD 

   18

12.0 

SERVICE 

RECORD     19

13.0 

SPARES 

STOCKISTS 

    20

Содержание 10 Litre 1kW

Страница 1: ...1 STREAMLINE UNDERSINK Fitting Instructions and User Guide...

Страница 2: ...CATIONS 4 3 0 INSTALLATION 6 4 0 COMMISSIONING 10 5 0 EXPLANATION TO USER 11 6 0 MAINTENANCE 12 7 0 FAULT FINDING 14 8 0 SPARE PARTS 15 9 0 GUARANTEE 17 10 0 ENVIRONMENTAL INFORMATION 17 11 0 COMMISSI...

Страница 3: ...instructions left with them for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experien...

Страница 4: ...10 4Kg full Weight 10 Litre 3 8Kg empty 13 8Kg full Enclosure rated IPX4 Operating Pressure 0 MPa 0 bar TABLE 01 PERFORMANCE DATA MODEL HEAT UP MINUTES HEAT LOSS kWhr 24hr 7 Litre 1kW 25 0 5 7 Litre...

Страница 5: ...5 18 5 70 A 477 213 32 5 17 100 345 450 518 289 FIGURE 02 DIMENSIONS IN mm THIRD FIXING HOLE DIMENSION A 7 LITRE 10 LITRE 278 178...

Страница 6: ...and that there are no hidden services electricity gas or water below the surface of the wall 2 DO NOT install the Streamline where it may freeze 3 Select a suitable location for the Streamline Allow 1...

Страница 7: ...e 2 p5 5 Remove the Streamline drill the third fixing hole and fit the third smallest fixing plug 6 Hang the Streamline on the wall bracket again and fix securely with the third smallest fixing screw...

Страница 8: ...aptor pipes The inlet is on the right the outlet is on the left see figure 5 below 3 Fit the flow restrictor in the incoming supply see figure 5 below NOTE It is recommended that a WRAS listed isolati...

Страница 9: ...ng switch having a contact separation of at least 3mm in each pole must be incorporated in the supply 3 The Streamline must be fitted with a 3 core 1 5mm2 flexible cable The cable must be fitted throu...

Страница 10: ...re The maximum setting is 70 C and the minimum is 5 C Rotate the thermostat knob clockwise to increase the temperature and anticlockwise to decrease the temperature Settings above 60 C are recommended...

Страница 11: ...the Streamline will expand during heating causing the tap to drip This is normal and is not a fault with the Streamline 5 2 SYSTEM MALFUNCTION 1 Explain how to isolate electrical and water supplies i...

Страница 12: ...peration 6 1 DRAIN THE STREAMLINE 1 Ensure the water and power supplies to the Streamline are switched off and the water is cold 2 Remove the thermostat knob use a medium sized flat bladed screwdriver...

Страница 13: ...ect alignment 7 Refit the locknut rotate the locknut clockwise until the EPA is held securely in place NOTE When tight one of the locknut spokes should be at 9 O Clock and central to the live and neut...

Страница 14: ...urn on Insufficient mains pressure Check supply Blockage in tap Clean tap No hot water No water in heater Fill water heater Cut out has operated Reset cut out Faulty thermostat Replace thermostat Faul...

Страница 15: ...1 3kW Element Plate with O ring 95606918 2 EPA O Ring pack of 10 95611018 3 EPA Locknut 95607617 4 7 Litre Inner Container 95608028 4 10 Litre Inner Container 95608029 5 Drain Pug with O ring 95608929...

Страница 16: ...16 FIGURE 12 SPARE PARTS 8 7 5 1 9 2 4 3 11 10...

Страница 17: ...with and has been regularly maintained 4 The Streamline has been used only for heating potable water The Streamline is not guaranteed against damage by frost or due to the build up of scale Please no...

Страница 18: ...er Electrical ________________________________________ Contact Details ____________________________________________ Competency Scheme ID Number _________________________ Comments _____________________...

Страница 19: ..._____________ ________________________________________________ ________________________________________________ Service Date _______________________________________________ Engineer __________________...

Страница 20: ...e Springfield Road Hayes Middlesex UB4 0TY Tel 020 8606 3567 Parts Center Tel 0845 2709800 www partscenter co uk Newey Eyre Unit 3 4 5 Wassage Way Hampton Lovett Industrial Estate Droitwich Worcesters...

Отзывы: