background image

1

Model

: TM1-TS / TM1-NTS

Model: 

TM1-TS / TM1-NTS

Содержание TM1-NTS

Страница 1: ...1 Model TM1 TS TM1 NTS Model TM1 TS TM1 NTS...

Страница 2: ...s Installation Procedure LCD Display Operating Modes Setting the Operating Mode Setting the Clock Clean Screen Locking the Time Clock Programming 5 2 Day and 7 Day Time Clock Mode Setting Countdown Mo...

Страница 3: ...bottom face of the time clock Step 2 Place the time clock front somewhere safe Terminate the time clock as shown in the diagrams on pages 19 21 of this booklet Step 3 Screw the time clock back plate...

Страница 4: ...t group 6 Keypad Lock Icon Displayed when the keypad is locked 7 ON OFF Keys Use to switch the hot water output Press and hold OFF to turn the display off 8 Clean Screen Freezes screen temporarily to...

Страница 5: ...his mode you can program 4 switching times for the weekdays and 4 different switching times for the weekend 7 Day Time Clock In this mode you can program 4 switching times for each day of the week Cou...

Страница 6: ...urs Change Hours Minutes Day Change Minutes Locking the Keypad The time clock has a keypad lock facility To activate the lock press the bottom right corner of the display and hold for 10 secs When act...

Страница 7: ...e clock will display Sat Sun prompting you to program the switching times for the weekend In 7 Day mode the time clock will display Tue Default switching times are pre programmed but you can change th...

Страница 8: ...as been overridden The time clock will return to the program at the next programmed time To cancel the Override repeat the steps above Countdown Mode Use the Up Down keys to set the countdown duration...

Страница 9: ...the ON key once to turn the thermostat display back ON Factory Reset During a holiday the time clock will maintain TIMER OFF At the end of your holiday the time clock will revert back to the programm...

Страница 10: ...06 Communications Address TM1 NTS only This setting is used when you have connected your time clock to a network system Each time clock on the network must have a unique communication address This can...

Страница 11: ...oiler makers wiring diagram Recommendations Max Cable Size 1 5mm Max Load 3 Amp Back Box Depth 35mm TM1 TS N L NC NO 230VAC COM To Boiler N L Neutral C Common Connection NO Normally Open NC Normally C...

Страница 12: ...etc Refer to the manufacturers instructions for wiring to these devices Common time clock wiring requirements are shown in the diagrams on pages 19 21 Wiring Diagram TM1 NTS Important Use shield cable...

Страница 13: ...Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com PDF FAQ Heating Professionals Request a copy of our product installation guide con...