Heatmiser PRT-R2 Скачать руководство пользователя страница 1

Operating

Instructions

PRT-R2
REV: 1

Heatmiser UK Ltd         Tel: +44(0)1254 776343
Primrose House

www.heatmiser.co.uk

Primrose Street
Darwen
Lancashire 
BB3 2DE

PRT-R2 Manual REVISION 1.qxd  18/11/2005  12:27  Page 1

Содержание PRT-R2

Страница 1: ...perating Instructions PRT R2 REV 1 Heatmiser UK Ltd Tel 44 0 1254 776343 Primrose House www heatmiser co uk Primrose Street Darwen Lancashire BB3 2DE PRT R2 Manual REVISION 1 qxd 18 11 2005 12 27 Page 1 ...

Страница 2: ... 11 Temporary Temperature Adjust 12 Turning the Heating Off 12 Setting the comfort levels 13 14 Wiring PRT R2 Wiring Diagrams 16 1 2 Power On Off Clock Button H Button A Button Down Button Up Button InfraRed Receiver Button Layout PRT R2 Manual REVISION 1 qxd 18 11 2005 12 27 Page 3 ...

Страница 3: ... been sunk in the wall prior to installation 2 The thermostat should be mounted at around 6ft or eye level 3 Do not install near a direct heat source Step 1 Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver in to the slots on the bottom face of the thermostat 3 4 PRT R2 Manual REVISION 1 qxd 18 11 2005 12 27 Page 5 ...

Страница 4: ... thermostat as shown in the diagrams at the back of this booklet Screw the thermostat back plate on to the back box Step 3 Re connect the thermostat ribbon cable and clip the two halves together Step 4 Turn on the power to the thermostat and allow the thermostat to stabilise for 1 hour before calibrating 6 5 PRT R2 Manual REVISION 1 qxd 18 11 2005 12 27 Page 7 ...

Страница 5: ...tat off Press and A for 3 seconds You can now enter the required temperature Press the Off button to store C Calibrating the PRT R2 The PRT R2 has a room built in to the thermostat and remote floor sensor The room sensor must be calibrated when it is first installed The floor sensor does not require calibration To calibrate the sensor first obtain an accurate sensor reading from an accurate thermo...

Страница 6: ...ll program settings are retained in flash memory for 10 years E Enabling Disabling the floor limit sensor The PRT R2 is supplied with a floor sensor probe This sensor is used to prevent the floor from overheating The floor sensor is enabled as a factory default to disable follow the steps below With the thermostat turned on press the H and Up arrow key for 5 seconds 00 Disabled 01 Enabled Factory ...

Страница 7: ...ewing the Floor Temperature Press and hold the A button to view the floor temperature Temperature Override Using the Up Down arrow keys you can adjust the current set temperature On the screen you will see SET and the new temperature displayed This temperature will be maintained until the next programmed comfort level Turning The Heating Off Frost Protection By pressing the H button the thermostat...

Страница 8: ... you should program the unused levels to You are now able to program the first comfort level for the weekday Follow these steps To begin programming the comfort levels press once You will see Mo Fr displayed Use the Up Down arrow keys to select the time for the 1st comfort level for the weekday Press H to accept Enter the required temperature for the 1st comfort level Repeat for comfort levels 2 4...

Страница 9: ...bled 01 enabled Press A to store Turning on the Keylock With the thermostat turned on press A and UP for 10 seconds You will see on screen This shows the keylock function has been enabled To cancel press A and UP for a further 10 seconds 15 16 Set point range 5 35 C Room Set point range 20 45 C Floor Switch Current Rating 16A Heatmiser PRT R2 L N PRT R2 Manual REVISION 1 qxd 18 11 2005 12 27 Page ...