background image

18

17

Slimline 

Series

Model

: PRT-E

Pressing the Power button          once will place the thermostat in frost protect mode. 
In this mode, the thermostat will display the frost icon and will only turn the heating

on should the room temperature drop below the set frost temperature (see page 20). 
Should the heating be turned on whilst in frost mode, the flame icon will be displayed. 
To cancel the frost protect mode, press the Power button once again.

Frost Protection Mode Enabled

Frost Mode

Holiday

Holiday Days

Holiday ON Indicator

Note:  A holiday period does not start until 00:00 the next day.  For example, if you set 

a holiday period on Friday for 2 days, Saturday will be counted as the first day and the 

thermostat will revert back to the programmed schedule at 00:00 on Monday.

The holiday function reduces the set temperature in your home to the frost 

protection  temperature setting (see page 23).

The thermostat will maintain this temperature for the duration of the holiday and will 

then automatically return to the program mode on your return.

• 

Press H three times (until you see the suitcase on screen) .................................

• 

Use the Up/Down keys to enter the number of days holiday ...................

• 

Press A to confirm settings and return to main display .......................................

The display will show a suitcase indicating the thermostat is in holiday mode.

To cancel, follow the same steps but reduce the Holiday duration to 00 days.

Содержание PRT-E1

Страница 1: ...1 Model PRT E Model PRT E...

Страница 2: ...le of Contents What is a Programmable Room Thermostat Installation Procedure LCD Display Operating Mode Setting the Clock Temperature Display Setting the Comfort Levels Locking the Thermostat Setting...

Страница 3: ...working properly What is a Programmable Room Thermostat A programmable room thermostat is both a programmer and a room thermostat A programmer allows you to set On and Off periods to suit your own lif...

Страница 4: ...bottom face of the thermostat Step 2 Place the thermostat front somewhere safe Terminate the thermostat as shown in the diagram on page 26 of this booklet Step 3 Screw the thermostat back plate secure...

Страница 5: ...re limit set on feature 09 6 Temperature Hold When a Temp Hold is active HOLD FOR and the remaining time period is displayed 7 Set Indicates when changes are being made to programs or temperature set...

Страница 6: ...4 main operating modes Select the mode that best suits your needs Mode 00 or 02 MUST NOT be used to control electric underfloor heating Mode 01 or 03 default with floor sensor option must be used Pres...

Страница 7: ...nds For 7 Day programming each day can have 4 different comfort levels To program comfort levels press Clock once For 7 Day programming only Mon is displayed in the day indicator field For Weekday Wee...

Страница 8: ...er the required WAKE time Press H to confirm settings Use the Up Down keys to enter the required WAKE temperature Press H to confirm settings You will now see LEAVE displayed on screen Repeat the prog...

Страница 9: ...see the Hold For indication is displayed on screen The time will countdown the set duration and then revert to the normal program To cancel temperature hold follow the same steps but reduce the Hold t...

Страница 10: ...ay For example if you set a holiday period on Friday for 2 days Saturday will be counted as the first day and the thermostat will revert back to the programmed schedule at 00 00 on Monday The holiday...

Страница 11: ...he range is 07 17 C The default is 12 C and is suitable for most applications Feature 05 Output Delay To prevent rapid switching an output delay can be entered This can be set from 00 15 minutes The d...

Страница 12: ...Feature 09 Floor Temp Limit This function is available when feature 08 is set to 03 or 04 You can set a floor limiting temperature between 20 45 C 28 C is the default Feature 10 Optimum Start Optimum...

Страница 13: ...le 01 02 03 04 05 06 07 08 09 10 11 12 FEATURE Temperature Format Switching Differential Frost Mode Frost Protection Temperature Output Delay Communications ID No Up Down Temperature Limit Sensor Sele...

Страница 14: ...mplete Factory Reset The thermostat has a reset function to restore all settings to their factory defaults To perform a factory reset follow these steps Press and hold the Power button to turn the the...

Страница 15: ...on Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com PDF FAQ Heating Professionals Request a copy of our product installation guide c...