Installation Procedure
This neoStat-hw is designed to be flush mounted and requires a back box of
35mm (minimum depth) to be sunk into the wall prior to installation.
Step 1
Remove the screw from the bottom face of the time clock then carefully separate
the front half from the back plate.
Step 2
Place the time clock front somewhere safe.
Terminate the time clock as shown in the diagrams on pages 18-19 of this booklet.
Step 3
Screw the time clock back plate securely into the back box.
Step 4
Clip the front of the time clcok onto the back plate, securing it in place with the
retaining screw.
Do
Mount the time clock at eye level.
Read the instructions fully so you get the best from our product.
Don’t
Do not install near to a direct heat source as this will affect functionality.
Do not push hard on the LCD screen as this may cause irreparable damage.