24
23
WiFi
Series
Model:
DT-ETS WiFi RF
To adjust the optional settings, follow these steps.
•
Press SETUP ..................................................................................................................
•
Use the Up/Down keys at the top of the screen to select the feature
number (shown on page 24) and then use the Up/Down keys in the
center to adjust the setting ....................................................................................
•
Press DONE to confirm settings and exit ...........................................................
Adjusting the Optional Settings
Feature Number
Setting Value
01
02
03
04
05
06
07
08
09
10
11
12
13
FEATURE
Temperature Format
Switching Differential
Frost Protect
Frost Protection Temperature
Output Delay
Not used on this model
Receiver Address
Not used on this model
Not used on this model
Fail Safe
Up/Down Temperature Limit
Sensor Selection
Floor Temperature Limit
DESCRIPTION
00 =
o
C
01 =
o
F
(°C = Default)
0.5
o
- 3.0
o
C (1.0
o
C = Default)
00 = Disabled
01 = Enabled
(01 = Default)
07
o
- 17
o
C (12
o
C = Default)
00 - 15 Minutes (00 = Default)
RC2-W = 01-32
00 = Disabled, 01 = Enabled
00 - 10
o
C
00 = Built in sensor, 01 = Remote air sensor
20
o
- 45
o
C (28
o
C = Default)
SETTING
Optional Settings - Feature Table
Содержание DT-ETS WiFi RF
Страница 1: ...1 Model DT ETS WiFi RF Model DT ETSWiFi RF...