FOR YOUR SAFETY READ BEFORE LIGHTING

A.  This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. 

This appliance is equipped with a push button piezo ignition device which can be used to light the pilot. If the piezo 
fails to ignite the pilot, then follow the instructions for lighting pilot with match. 

B.  BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS

+

Do not try to light any appliance.

+

Do not touch any electrical switch; do not use any phone in your building.

+

Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions.

+

If you cannot reach your gas supplier, call the fire department.

C.  Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn 

by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or 
explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information previously listed above.
2. Turn main gas control knob (FIG. 7) clockwise        to the “OFF” position.
3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow

“B” in the safety information above on this label. If you don’t smell gas, go to the next step.

4. Locate pilot - mounted on the inside of the right hand bracket that holds the burner in place, just behind the front 

part of the burner. (FIG. 6)

5. Depress main control knob (FIG. 7) slightly and turn  counterclockwise         to the “PILOT” position.

With main control knob (FIG. 7) at “PILOT”, depress until it stops and press on the igniter push-button several 
times. (FIG. 7) This will cause a spark at the pilot burner which will ignite the pilot flame. Continue to hold the main 
control knob (FIG. 7) in for about (1) minute after the pilot is lit. Release knob and it will pop back out. Pilot 

should remain lit. If it goes out, repeat steps 1 through 5.

+

If the knob does not pop out when released, stop and immediately call your service technician or gas supplier.

+

LIGHTING PILOT WITH MATCH:  Turn main control knob (FIG. 7) to the “PILOT”position. Place a lit match at 
the pilot burner, then push the main control knob in. Continue to hold the control knob in for about one (1) minute 
after the pilot is lit. Release knob and it will pop back out. Pilot should remain lit. If it goes out, repeat the above 
step. 

+

If the pilot will not stay lit after several tries, turn the gas control knob (FIG. 7) to “OFF” and call your service 
technician or gas supplier.

6. Slightly depress main control knob (FIG. 7) and turn counterclockwise        to the “ON” position. Adjust heat output 

to the desired level by turning the HI/LOW control knob.

TO TURN OFF GAS TO APPLIANCE

Turn main gas control knob (FIG. 7) clockwise        to the “OFF” position. Do not force. 

T

H

T

P

T

P

 T

H

PIL

OT

it

PILO

T

S

ON

OF

F

LO

HI

FIG. 6

WARNING:

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 
personal injury or loss of life.

FIG. 7

ON/OFF

SWITCH

PIEZO

IGNITOR

PILOT BURNER

Содержание HM2-MAN

Страница 1: ...tallation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause property damage...

Страница 2: ...ION READ COMPLETE INSTRUCTIONS CAREFULLY DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM WARNING Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot c...

Страница 3: ...mpartment clean WARNING A Due to high surface temperatures the appliance should be located out of traffic and away from furniture and draperies B Children and adults should be alerted to the hazard of...

Страница 4: ...lace with a mantle always follow guidelines listed in the Installation Clearances section of this brochure If a hood is required to be installed on your fireplace due to mantle clearances contact your...

Страница 5: ...at other openings Instructions for determining maximum Btu s for a room Step 1 This calculation is for combustion and ventilation air provisions only and is not intended to be used for sizing for hea...

Страница 6: ...eplace opening to part of a mantle piece should not be less than 6 inches See figure at right Minimum Mantle Clearance Without Hood Minimum Mantle Clearance With Hood HEAT RESISTANT MATERIAL 12 MINIMU...

Страница 7: ...aximum inlet gas supply pressure must not exceed 10 5 WC for natural gas or 14 WC for LP gas The gas line supplying the appliance must be sufficient size to furnish the appropriate supply pressure to...

Страница 8: ...gs they may be incorrectly placed There should not be any carbon or blackening on the logs at any time 5 Place the back log in the grooves on the elevated cradle toward the back of the grate making su...

Страница 9: ...set has two settings HI and LOW You can burn your log set at the range you prefer 8 To turn you log set completely off simply rotate the control knob clockwise to the OFF position If this is done the...

Страница 10: ...positions The ON OFF control knob cannot be turned unless it is pushed in slightly 1 Place the ON OFF control knob in the OFF position 2 Follow the safety information on page 16 of this instruction ma...

Страница 11: ...nob 8 Follow the safety information on page 16 of this instruction manual 9 Follow the lighting instructions on page 16 of this instruction manual 10 After lighting the pilot and turning on the main O...

Страница 12: ...the accessories To hook up this accessory you must follow these instructions Notice the electric terminal block on the control valve located on the left hand side of the valve when facing the front o...

Страница 13: ...2 RO 24 Front View HM2 RO 24 Side View HM2 RO 33 Front View HM2 RO 33 Side View 13 WARNING Failure to position the parts in accordance with these diagrams or failure to use only the parts specifically...

Страница 14: ...2 SO 24 Front View HM2 SO 24 Side View HM2 SO 33 Front View HM2 SO 33 Side View 14 WARNING Failure to position the parts in accordance with these diagrams or failure to use only the parts specifically...

Страница 15: ...formation above on this label If you don t smell gas go to the next step 4 Locate pilot follow metal tube from gas control The pilot is mounted on a bracket that is fastened to the side of the right h...

Страница 16: ...on above on this label If you don t smell gas go to the next step 4 Locate pilot mounted on the inside of the right hand bracket that holds the burner in place just behind the front part of the burner...

Страница 17: ...y measurements are approximate Flame heights may vary slightly Fireplaces can be very dusty areas therefore at least monthly during the heating season clean the unit by following the guidelines below...

Страница 18: ...18 MANUAL AND THERMOSTATIC VALVES MILLIVOLT VALVES 18 Log Set 24 Log Set 33 Log Set PROPANE GAS NATURAL GAS NATURAL GAS PROPANE GAS...

Страница 19: ...permanent free opening in square inches that must be provided by either a fireplace chimney or chimney damper must be provided See chart on next page The chimney damper must be fixed in a manner whic...

Страница 20: ...6 10 8 9 6 9 1 8 7 5 18 Log Set Natural Gas 16 6 12 6 10 8 9 6 9 1 8 7 5 24 Log Set LP Gas 22 1 17 3 14 5 12 6 11 3 10 8 10 2 24 Log Set Natural Gas 22 1 17 3 14 5 12 6 11 3 10 8 10 2 33 Log Set LP G...

Страница 21: ...Log Back Log Right Log Left Bottom Log Left Top Log Middle Top Log Front Log KEY NUMBER 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 DESCRIPTION Middle Log Back Log Right Log Left Lo...

Страница 22: ...V U T E FF T H TO ALL PILOTS DD C D D C EE D C HM2 MILLIVOLT LP PILOT B HM2 MILLIVOLT VALVE ASSEMBLY DD B CC FF G G L N M Q K J O P HM 2 M ANUAL VALVE ASSEM BLY HM2 MILLIVOLT NAT PILOT E PILOT REGULAT...

Страница 23: ...ass 3 8 MPT to 3 8 Flare Male Half Union Regulator 10 0 LP 3 8 Regulator 4 0 Nat 3 8 3 8 Nipple 3 5 long Valve Manual SIT 522 Valve Thermostatic SIT 504 KEY LETTER N N O O P Q R R S T U U V W X Y Z AA...

Страница 24: ...d warranty of merchantability or fitness applicable to this product is limited to the duration of this warranty HEATMASTER Inc shall not be liable for loss of use of this product loss of time inconven...

Отзывы: