2. INTRODUCTION & SPECIFICATION

 

This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being turned 
on and has a highly polished aluminium reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is Ideal for 
industrial or domestic applications, IP55 rated. 

 

Model HLW30 

Series 

  

Power 3000W 

  

Input supply 

240V 50Hz 12.5A 

 

 

Dimensions (W x H x D) 

960 x 125 x 125mm

 

 

 

Mounting Bracket Stand Off 

45mm 

 

 

Minimum Mounting Height 

1.8m

 

 

 

 

 

3. MOUNTING INSTALLATION 

 

3.1  WALL MOUNTING (fig.1) 

 IMPORTANT!

 The following points should be noted: 

The heater 

should always have a minimum clearance of 500mm from a 
ceiling and at least 1000mm from any object. 

 IMPORTANT!

 Ensure that the mounting surface is capable of 

supporting the weight of the heater. 

 IMPORTANT!

 

The heater should be mounted horizontally where 

possible or at a maximum angle of 35 degrees from the horizontal.

 

 IMPORTANT! 

The mounting bracket must be sufficiently earthed.

 

3.1.1 Remove the wall mounting bracket from the heater by removing 

the two bolts from either end of the bracket. 

3.1.2  Before drilling ensure that there are no wires or water pipes in the 

area where the heater is to be placed.

 

3.1.3  Use the bracket as a template. Fix the metal bracket to the wall by 

means of the three holes and appropriate fixings (not supplied).

 

3.1.4 Refit the heater back onto the bracket and secure with the two 

bolts.

 

3.1.5 Adjust the angle of heater to direct heat where required, between 

45° and 90° (see fig.1).

 

 

3.3 ELECTRICAL 

CONNECTION 

3.3.1 Please make sure you have read the Safety instructions and 

you are a suitably qualified electrician before continuing. 

3.3.2 UK ONLY – If connecting to a 13A Plug 

a) Connect the GREEN/YELLOW earth wire to the earth terminal 
‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’. 
c) Connect the BLUE neutral wire to the neutral terminal ‘N’. 
d) After wiring, check that there are no bare wires, that all wires 
have been correctly connected, that the cable outer insulation 
extends beyond the cable restraint and that the restraint is tight. 

3.3.3 

Connection to a Switched Fused Spur / Isolator.

 

a) Connect the GREEN/YELLOW earth wire to the earth 
connection.

 

b) Connect the BROWN live wire to the live connection. 
c) Connect the BLUE neutral wire to the neutral connection’. 
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends 
beyond the cable restraints and that the restraint is tight. 

 

 