background image

1.  INTRODUCTION

Heatit ZM Thermostat 16A is an electronic thermostat for electrical 
floor heating designed for in-wall installations. 
The thermostat allows you to control your electrical heating through 
your Z-Wave™ network. The module is equipped with a 16A single pole 
relay. The thermostat requires you to connect an external wired sensor 
which is included with the device.
The device can withstand a max load of 16A at 230VAC.

2.  STATEMENT REGARDING PRODUCTS FROM MULTIPLE  

 

 MANUFACTURERS
Please read this before installation

This device may be used with all devices certified with the Z-Wave 
Plus™ certificate and should be compatible with such devices 
produced by any manufacturer. Every primary controller is different 
depending on the manufacturer, their target audience and intended 
use/application. Please review the functionalities implemented by the 
primary controller you intend to use with our Z-Wave Plus certified 
device to ensure that it provides the necessary controls to take full 
advantage of our product’s capabilities.

3.  BEHAVIOR WITHIN THE Z-WAVE™ NETWORK

This device may be operated within any Z-Wave network with
Z-Wave-certified devices from other manufacturers. All non-battery-
operated nodes within the network will act as repeaters regardless of 
manufacturer to increase the reliability of the network. On delivery, the 
device does not belong to any Z-Wave network. 
The device needs to be added to an existing network to communicate 
with the other devices within it. Devices may also be removed from 
a network. The add/remove processes are initiated by the primary 
controller of the Z-Wave network.

4.  QUICK START

1.  Switch off the mains supply (disable the fuse).
2.  Open the wall box.
3.  Connect the wires according to the description in Chapter 5; 

”Installation”.

4.  After verifying the connections, switch the mains supply back on.
5.  Set the primary controller in add mode (security/non-security).
6.  Press the configuration button 3 times in rapid succession.
7.  The device LED will blink in green when the adding procedure has 

been successfully initiated. When the device is included in the home 
automation system, the LED will light up in green for 3 seconds.

5.  INSTALLATION

Installation must be done by a qualified electrician in accordance with 
the national building codes. Before installation, disconnect any power 
to the device mains. During installation of the device, power to the 
device must be disconnected AT ALL TIMES!

The product allows for wiring of cables with a cross section of up to 
1x2.5mm

2

TABLE OF CONTENTS
1. 

Introduction

2. 

Statement regarding products from multiple manufacturers

3. 

Behavior within the Z-Wave™ network

4. 

Quick Start 

5. 

Installation

6. 

Add/Remove

6.1 

Method 1: Standard (Manual)

6.2 

Method 2: SmartStart (Automatic)

7. 

Factory Reset

8. 

Startup

9. 

Principles of regulation

10. 

Hysteresis

11. 

Safety Features

11.1 

Overload

11.2 

Overheating

12. 

Calibration

13. 

LED Blinking patterns description

14. 

QR-Code placement (DSK)

15. 

Security

16. 

Node Information Frame

17. 

Associations

17.1 

Setting and removing associations

17.2 

Associations Groups

18. 

Configuration Parameters

19. 

Command Classes

19.1 

Basic Command Class

19.2 

Binary Switch Command Class

19.3 

Meter Command Class

19.4 

Indicator Command Class

20. 

Supported Command Classes
Product Information

HEATIT ZM 

THERMOSTAT 

16A

Ver 2021-A

Firmware 1.0

01.09.2021

Installers manual

Содержание ZM 16A

Страница 1: ...he primary controller of the Z Wave network 4 QUICK START 1 Switch off the mains supply disable the fuse 2 Open the wall box 3 Connect the wires according to the description in Chapter 5 Installation 4 After verifying the connections switch the mains supply back on 5 Set the primary controller in add mode security non security 6 Press the configuration button 3 times in rapid succession 7 The devi...

Страница 2: ...emperature readings retrieved from the sensor to regulate heating When you have chosen a setpoint temperature the thermostat will use an internal hysteresis to regulate the temperature 10 HYSTERESIS You can make changes to the thermostat hysteresis You may change the hysteresis from between 0 3 C and 3 0 C using parameter 2 The default setting is 0 5 C When using water based heating the recommende...

Страница 3: ...5 digit code which can be found underneath 0s 1s 2s 3s 4s 5s 0s 1s 2s 3s 4s 5s the QR Code The primary controller will then ask you to confirm the rest of the code that is contained in the QR Code 16 NODE INFORMATION FRAME The node information frame is the business card of a Z Wave device It contains information about the device type and its technical features The add and remove procedure of the d...

Страница 4: ...thermostat 50 400 400 40 C 5 0 C to 40 0 C 5 2 Ther mostat setpoint Decides the ther mostat setpoint 50 400 210 21 C 5 0 C to 40 0 C 6 1 Sensor calibration Manually calibrates the sensor by 6 C 60 60 0 6 0 C to 6 0 C Calibrates the sensor by 6 C NB To set a negative value use 256 and subtract the desired value 7 2 Tempera ture report interval Sets time interval between consecutive temperature repo...

Страница 5: ...tit ZM Thermostat 16A Grey RAL 6015 EU 868 4MHz PRODUCT INFO Heatit ZM Thermostat 16A FEATURES Z Wave thermostat for in wall installations 16A 3600W NTC 10 sensor SmartStart Firmware update OTA Power Metering Supports encryption modes S0 S2 Authenticated Class S2 Unauthenticated Class This product is a security enabled Z Wave Plus product with encryption The product must be used with a security en...

Отзывы: