background image

34922 Rev B

16

12-01

T4800 INSTALLATION INSTRUCTIONS

Figure 14 - Ceiling/Attic Construction

Figure 15 - Air Kit Handle Location

9. Marking the Exit Point of the Roof

Locate the point where the chimney will exit the roof

by plumbing down to the center of the chimney. Drive

a  nail  up  through  the  roof  to  mark  the  center.  See

Figure 14.

10.Cutting out the Hole in the Roof

Measure  to  either  side  of  the  nail  and  mark  the

17” x 17”  or  17”  x  26”  opening  required.  This  is

measured  on  the  horizontal;  actual  length  may  be

larger depending on the pitch of the roof. Cut out and

frame  the  opening.  See  Chapter  25  of  the 

Uniform

Building Code for Roof Framing Details.

Be  sure  to  maintain  a  2”  minimum  air  space

between the chimney section and the roof.

11. Assembling the Chimney Sections

Through the Roof

Continue  to  add  chimney  sections  through  the  roof

opening, maintaining at least a 2” air space.

12.Installing the Roof Flashing

If a roof flashing is to be used, install the roof flashing

appropriate  to  the  roof  pitch  and  install  a  round

termination  cap  following  the  instructions  shipped

with the cap.

For  chase  installations  you  can  use  a  round

termination  cap  (TR11),  a  round  telescoping

termination cap (TR11T) or a square termination cap

(ST1175). A chase installation must use a chase top.

Chase  tops  are  available  from  your  Heatilator

distributor. See page 20 for building a chase.

13.Installing the Outside Air Kit

The outside air kit is supplied as a standard feature

with this fireplace and its use is highly recommended

to minimize the effects of negative pressure within the

structure.  It  is  recommended  to  utilize  the  shortest

duct  run  to  optimize  the  performance  of  the  outside

air  kit.  The  outside  air  kit  inlet  thimble  should  be

positioned at least four feet above the ground level,

in a manner that will not allow snow, leaves, etc. to

block the inlet.

The outside air kit is installed on the left hand side of

the fireplace. Remove the cover plate from the side of

the  fireplace  assembly  where  the  air  kit  is  to  be

installed. See Figure 15 for handle location.

14.Installing the Chimney Air Kit

When  installing  the  chimney  air  kit,  follow  the

instructions  provided  with  this  accessory.

Содержание traditional T4800

Страница 1: ...tion service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier TRADITION...

Страница 2: ...n air kit may not provide all the air required to support combustion Hearth Technologies Inc is not responsible for any smoking or related problems that may result from the lack of adequate combustion...

Страница 3: ...the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fireplac...

Страница 4: ...s The illustrations and diagrams used throughout these installations instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM This fireplace system h...

Страница 5: ...c a l B w e i V r a e l C d l o f i B s r o o D s s a l G B 8 4 3 1 M D s s a r B d e h s i l o P w e i V r a e l C d l o f i B s r o o D s s a l G S 8 4 3 1 M D l e e t S s s e l n i a t S w e i V r...

Страница 6: ...e S y e n m i h C 8 4 1 1 L S g n o l 8 4 n o i t c e S y e n m i h C 1 1 L S r e z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s...

Страница 7: ...n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12 Pitc...

Страница 8: ...12 01 T4800 INSTALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11 Round Termination Cap TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A C...

Страница 9: ...the clearance is Chimney sections at any level require a 2 minimum air space clearance between the framing and chimney section Figure 3 Installation Along a Wall or an Exterior Chase r i A e d i s t...

Страница 10: ...e fireplace assuming combustible materials are used All required clearances to combustibles around the fireplace must be adhered to Any framing across the top of the fireplace must be above the level...

Страница 11: ...5 8 1 3 2 5 8 8 4 1 1 7 2 5 5 1 9 2 5 8 9 5 1 1 2 3 5 8 4 6 1 1 5 3 5 8 9 6 1 1 8 3 3 7 5 8 2 1 1 4 8 7 1 1 1 4 4 5 8 5 8 1 1 7 4 9 8 1 8 1 1 1 0 5 5 8 5 9 2 n a n i s t l u s e r s t r a p y e n m i...

Страница 12: ...ireplace installation d Determine the number of firestop spacers sta bilizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major bu...

Страница 13: ...instructions for framing on pages 9 and 10 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Placing the Protective Metal...

Страница 14: ...til the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney sect...

Страница 15: ...ulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it over the ver...

Страница 16: ...the roof pitch and install a round termination cap following the instructions shipped with the cap For chase installations you can use a round termination cap TR11 a round telescoping termination cap...

Страница 17: ...ith a maximum input of 100 000 BTU hour incorporating an automatic gas shut off device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces ANSI Z21 60 T...

Страница 18: ...st be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown...

Страница 19: ...those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electri...

Страница 20: ...8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21 This...

Страница 21: ...alling a TR11T Round Telescoping Termination Cap Figure 24 Installing an ST1175 Square Termination Cap 2 Chase Top Construct a chase of desired materials maintaining a minimum 2 air space around the c...

Страница 22: ...ances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas...

Страница 23: ...a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak har...

Страница 24: ...ood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process An...

Страница 25: ...ney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of soo...

Страница 26: ...curred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it you...

Страница 27: ...d 23 Flue 22 Framing 10 Fuel 2 23 G Gas Log Lighter Provisions 17 General Information 22 Glass Doors 5 19 Grate 23 H Hearth Extension 18 Positioning 19 I Installation Fireplace 13 Installation Along a...

Страница 28: ...xhaust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any ot...

Отзывы: