background image

Heatilator • SILHOUETTE Series Electric Fireplace • 4030-155 Rev K • 04/05

7

3  

Framing and Clearances 

A. Selecting Heater Location

Several options are available to you when choosing a loca-
tion for your heater. This heater may be used as a room 
divider, installed along a wall, across a corner or used in an 
exterior chase. See Figure 3.1. This heater may be installed 
directly on the fl oor, carpet or raised on a hearth.

Fire Risk

Provide adequate clearances.
•  Around air openings
• To 

combustibles

• For 

service 

access.

Locate heater away from traffi c areas.

WARNING

B. Clearances

Figure 3.1 shows all clearances that must be maintained 
around the heater.

Fire Risk

Due to high temperature, this 

heater

 should 

be located out of high traffi c areas.
•  Keep combustible materials such as 

furniture, pillows, bedding, papers, 
clothes and curtains at least 12 in. 
(305  mm) from the front of the 

heater

.

WARNING

Electrocution Risk

• 

NEVER

 locate this 

heater

 where it may fall 

into a bathtub or other water container.

•  Contact local building administrator for 

information on bathroom intallations.

DANGER

Fire Risk!

•  Prevent contact with sagging, loose 

insulation.

•  Do NOT install against vapor barriers or 

exposed insulation.

WARNING

Do NOT use this 

heater

 if any part has been under water. 

Immediately call a qualifi ed service technician to inspect 
the 

heater

 and to replace any part of the control system  

which has been under water.

WARNING

D

B

A

1 in. (26mm) min.

14 in.

(356mm)

14 in.

(356mm)

A

A

C

Figure 3.1 

Heater Locations

Fire Risk

•  Comply with all minimum clearances to 

combustibles as specifi ed.

Failure to comply may cause  fi re.

WARNING

Note: 

Minimum and maximum clearances must be 

maintained at all times. Illustrations throughout these 
instructions refl ect typical installations and are for design 
purposes only. Actual installation may vary slightly due to 
individual design preferences.

The

 

illustrations and diagrams used throughout these 

installation instructions are not drawn to scale.

Model

A

B

C

D

SILH50E 

Series

in.

36-1/4

45

22-1/2

31-7/8

mm

921

1143

572

810

SILH60E 

Series

in.

41-1/8

50

25

35-3/8

mm

1045

1270

635

899

Содержание SILH50E

Страница 1: ...H SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT WARNING Keep children away CAREFULLY SUPERVISE children in same room as heater Alert children and adults to hazards of high temperatures Keep clo...

Страница 2: ...tion contained in this owner s manual unless noted otherwise applies to all models Your new Heatilator electric replace will give you years of durable use and trouble free enjoyment Welcome to the Hea...

Страница 3: ...0 5 Heater Preparation 11 A Secure and Level the Heater 11 6 Finishing 12 A Finishing Material 12 B Finishing Checklist 12 C Mantel 13 7 Heater Setup 14 A Remove Shipping Materials 14 B Clean Heater 1...

Страница 4: ...2 No 46 in Canada and has been listed by Underwriters Laboratories Inc for installation as described in this manual All compo nents are UL or CSA safety certi ed This heater has been tested and listed...

Страница 5: ...ith throw rugs runners or the like Arrange cord away from traf c area and where it will not be tripped over To disconnect heater turn controls to OFF then remove plug from outlet Do not insert or allo...

Страница 6: ...remove the heater and components from the packaging Report to your dealer any parts damaged in shipment Read all the instructions before starting the installation Follow these instructions carefully...

Страница 7: ...into a bathtub or other water container Contact local building administrator for information on bathroom intallations DANGER Fire Risk Prevent contact with sagging loose insulation Do NOT install agai...

Страница 8: ...he heater must be adhered to A B header height 14 in 356 mm If using the PBT or BKT Cabinet Trim Kits increase the width A by 1 1 4 in 32 mm and header height B by 5 8 in 16 mm Mantel height listed is...

Страница 9: ...switches are in the OFF position To access the controls lift up on the lower grille panel and rotate it forward If the power cord is not being used go to Step B below If the cord does not reach the ou...

Страница 10: ...Remove the connectors on the wires from the heater and strip them back 1 2 in Feed 8 in of service wire through cable clamp not provided and secure Connect black white and red wires of the heater to t...

Страница 11: ...eater Installation other than as instructed by Hearth Home Technologies Inc is strictly prohibited Do not operate the heater without fully assembling all components Installation and or use of any comp...

Страница 12: ...nailing anges Allow room for the front to be added and the heater to be anchored B Finishing Checklist Power supply service must be either completed or placed within the heater prior to nishing to avo...

Страница 13: ...62 mm Figure 6 4 Mantel Speci cations Fire Risk Do NOT obstruct air inlet or outlet grilles Do NOT modify grilles Modifying or covering grilles could cause temperature rise and re hazard Finishing mat...

Страница 14: ...discard Replace screws B Clean Heater The heater was cleaned at the factory but dust may have accumulated during shipping Vacuum rebox area and wipe acrylic panel in back of rebox with a dry lint fre...

Страница 15: ...e manual switches remote control and wall switch will not work MOTION INTENSITY THERMOSTAT HEATER MAIN POWER LEARN MOTION INTENSITY THERMOSTAT HEATER BLOWER ASSEMBLY SWITCH MAIN POWER SWITCH LEARN Fig...

Страница 16: ...ransmitter s battery Initialization only has to be done once Turn the main power switch on Locate the LEARN button on the dashboard The LEARN button is located behind the lower grille panel To push th...

Страница 17: ...ou would like to change the setting you will have to access the manual controls located on the heater to set the desired position The heater must be turned on and off by the wall switch D FCC Requirem...

Страница 18: ...is off 1 Turn the heater switch to the ON position 2 Thermostat is set too low 2 Move the thermostat knob clockwise until you hear a click 3 Heater blower assembly is overheated 3 The heater blower a...

Страница 19: ...panel can be cleaned with a damp cloth using a mild soap and water solution DO NOT USE GLASS CLEANER IT WILL RUIN THE ACRYLIC PANEL The acrylic panel should be com pletely dried with a lint free cloth...

Страница 20: ...eed to be pulled all of the way out of the heater Reach into the back of the left rear corner of the light tray and unplug wire harness from connector To remove plug squeeze both sides and pull Remove...

Страница 21: ...8 in 429 mm 36 in 914 mm 14 in 356 mm 31 in 787 mm 30 in 762 mm 17 1 4 in 438 mm 31 1 8 in 791 mm 3 1 8 in 79 mm 6 1 2 in 165 mm SILH50E SILH50EV SILH50ENH 22 in 559 mm 41 in 1041 mm 14 in 356 mm 34...

Страница 22: ...ON OFF BUTTONS RCE HTL B Remote Control DM1031 DM1036 DM1031B DM1036B DM1031S DM1036S Bi fold Glass Doors WSK 21 WSK 21 W Wall Switch Kit left right RF50E SILH50E Series RF60E SILH60E Series Side Ref...

Страница 23: ...0 SILH50E Series BKT 550 SILH50E Series PBT 6 SILH60E Series BKT 6 SILH60E Series Cabinet Trim no suf x Polished Brass Finish BK Black Finish TKE31B S SILH50E Series TK302B S SILH60E Series TKE1B S SI...

Страница 24: ...Heatilator SILHOUETTE Series Electric Fireplace 4030 155 Rev K 04 05 24 Marble Lux Marble Lux SILH50E Series SILH60E Series VML 550 G VML 36 G VML 550 BG VML 36 BG VML 550 BK VML 36 BK...

Страница 25: ...030 155 Rev K 04 05 25 C Service Parts Exploded Parts Diagram SILH50E Series SILH60E Series Service Parts SILHOUETTE Beginning Manufacturing Date 3 24 03 Ending Manufacturing Date Active 3 9 8 10 5 7...

Страница 26: ...t 33961 33961 2 14 Motor w Vinyl Cover Assy 4030 883 4030 883 1 12 Flame Element Kit 4030 200 4030 200 1 9 Screen Rod Assy 4030 050 4030 033 1 3 Grate Ember Bed Assy 4030 091 4030 094 1 Installation M...

Страница 27: ...y will not apply if in the sole judgment of the Company damage or failure has resulted from accident alteration misuse abuse incorrect installation or operation on an incorrect power source The forego...

Страница 28: ...Read understand and follow these instructions for safe installation and operation D O N O T D I S C A R D This product may be covered by one or more of the following patents United States 4593510 4686...

Отзывы: