Heatilator ODYSSEY ODY42 Скачать руководство пользователя страница 32

32

31818 Rev J

01/04

GAS APPLIANCE (FIREPLACE)

LIMITED LIFETIME WARRANTY

HEARTH & HOME TECHNOLOGIES INC. (“HHT”)

 extends the following warranty for HEATILATOR

â

 gas appliances installed in

the  United  States  of America  or  Canada  (the  “Appliance”).  Dealers  and  employees  of  HHT  have  no  authority  to  make  any

warranty or authorize any remedies in addition to or inconsistent with the terms of this warranty.

Limited Lifetime Warranty

HHT warrants the Appliance for component failure due to a manufacturing defect of any of the following components: combustion chamber,

burner pan, and logs. The Limited Lifetime Warranty specified above is subject to the conditions, exclusions and limitations listed below, is for

the period the Appliance is owned by the original homeowner only, and is nontransferable.

1 Year Limited Warranty

HHT warrants the Appliance to be free from failure of any of the following components for a period of one year after installation: valve, flexible

gas line connector, glass panel, fan, direct vent chimney components, factory paint, gasket, piezo ignitor, thermopile, thermocouple, junction

box,  pilot  assembly,  shutoff  valve,  high  limit  switch,  refractory  liners,  transformer,  and  control  box.  If  the  Heatilator Appliance  is  found  to  be

defective in either material or workmanship within one year of the date of original installation, HHT will provide replacement parts at no charge

and pay reasonable labor and freight costs, and is for the period of one year following the date of original installation of the Appliance.

Conditions, Exclusions, & Limitations of  Liability

A.

Both  the  Limited  Lifetime  and  1 Year  Limited  Warranties  supplied  by  HHT  apply  only  while  the Appliance  is  in  its  location  of      original

installation.  HHT’s obligation under this warranty does not extend to damages resulting from (1) installation, operation or maintenance of

the Appliance  not  in  accordance  with  the  Installation  Instructions,  Operating  Instructions,  and  the  Listing Agent  Identification  Label

furnished with the Appliance; (2) installation which does not comply with local building codes; (3) shipping, improper handling, improper

operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate ventilation or drafting caused by

tight sealing construction of the structure, air handling devices such as exhaust fans or forced air furnaces, or other causes;  (5) use of

fuels other than those specified in the Operating Instructions; (6) installation or use of components not supplied with the Appliance or any

other components not expressly authorized and approved by HHT; and/or (7) modification of the Appliance not expressly authorized and

approved by HHT in writing. This warranty is limited to only the component parts manufactured or supplied by HHT.

B.

HHT’s liability under both the Limited Lifetime Warranty and the 1 Year Limited Warranty is limited to the replacement and repair  of defective

components or workmanship during the applicable period.  HHT may fully discharge all of its obligations under such warranties by repairing

the  defective  component(s)  or  at  HHT’s  discretion,  providing  replacement  parts  at  no  charge  and  paying  reasonable  labor  and  freight

costs.

C. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY   SPECIFIED

HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY SPECIFIED ABOVE.

D.

Some states do not allow exclusions or limitations of incidental or consequential damages, so those limitations may not apply to you. This

warranty  gives  you  specific  rights;  you  may  also  have  other  rights  which  vary  from  state  to  state.

How to Obtain Service

To obtain service under this warranty you must:

1.

Send written notice of the claimed condition to Heatilator Technical Service Department, Hearth & Home Technologies, 1915 W. Saunders

Street, Mt. Pleasant, Iowa 52641-1563.  You may also register your claim online at www.heatilator.com/contact.asp.

2.

Provide proof of purchase, model number, serial number, and manufacturing date code to HHT.

3.

Provide HHT reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the Appliance prior to any repair

or replacement work and before the Appliance or any component of the Appliance has been removed from the place of original installation.

4.

Obtain HHT’s consent to any warranty work before the work is done.

ADDITIONAL INFORMATION:

If you would like information on current HEATILATOR products or want to locate a dealer in your area, call 1-800-927-6841.

ã

2003 Heatilator

â

 is a Registered Trademark of Hearth & Home Technologies Inc.

Содержание ODYSSEY ODY42

Страница 1: ...not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this...

Страница 2: ...r propane to natural gas is not available for the Odyssey Series fireplace The Odyssey must be purchased from the factory as either natural gas or propane An optional wood conversion kit ODYCKW is ava...

Страница 3: ...the design and construction stage of the home If you desire to put an appliance in your basement we recommend that you consider a direct vent gas appliance Basements always have a significant negative...

Страница 4: ...ion instructions will void the Underwriters Laboratories listing and may void the product warranty It may also create a hazardous installation Read through these instructions thoroughly before startin...

Страница 5: ...m i h C 3 L S r e z i l i b a t S y e n m i h C 5 1 3 L S 5 1 n r u t e R t e s f f O y e n m i h C 0 3 3 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 3 S F t h g i a r t S p o t s e r i F 9 3 3...

Страница 6: ...YSSEY SERIES FIREPLACE WITH GAS LOG SET HX4 HEARTH EXTENSION DM1742 Series GLASS DOORS GR19 GRATE supplied with ODYCKW AK22 OUTSIDE AIR KIT REMOTE CONTROLS RC BATT HTL RC SMART HTL SMART STAT HTL SMAR...

Страница 7: ...lat to 6 12 Pitch T A C A B 6 0 3 L S 6 4 3 4 2 1 3 L S 2 1 4 3 0 1 8 1 3 L S 8 1 4 3 6 1 4 2 3 L S 4 2 4 3 2 2 6 3 3 L S 6 3 4 3 4 3 8 4 3 L S 8 4 4 3 6 4 A h t g n e L l a u t c A B t r a p y e n m...

Страница 8: ...J 01 04 ODYSSEY SERIES FIREPLACE WITH GAS LOG SET TR342 ROUNDTELESCOPING TERMINATIONCAP TR344 ROUND TERMINATIONCAP WITH STORM COLLAR ST375 SQUARE TERMINATIONCAP TS345 345P SQUARE TERMINATION CAP CT35...

Страница 9: ...ectly outside without forming elbows Figure 3 Installation Along a Wall or an Exterior Chase WARNING Do not draw outside air from garage spaces Exhaust products of gasoline engines are hazardous Do no...

Страница 10: ...slots Do not cover any portion of the opening to the fireplace that would prevent the installation of an authorized glass door Combustible Materials Material made of or surfaced with wood compressed...

Страница 11: ...ombustible sealant Figure 5 Factory Built Hearth Extension Field constructed hearth extensions should be constructed in accordance with the minimum dimensions provided in Figure 6 Figure 6 Hearth Exte...

Страница 12: ...e considered The fireplace system and chimney components have been tested to provide the following flexibility in construction The following figures are the minimum distances from the base of the fire...

Страница 13: ...Table 1 the dimension closest to but not less than 14 1 2 is 14 5 8 using the 30 offset return It is then determined from the table that you would need 33 dimension B between the offset and return The...

Страница 14: ...buildings adjoining roof lines adverse wind conditions etc may create a need for a taller chimney should smoking occur 3 Determine the Number of Chimney Sections Required To determine the chimney comp...

Страница 15: ...front edge of the fireplace The individual pieces must overlap each other by one inch in the middle of the fireplace to provide continuous coverage of the floor See Figure 10 These metal strips shoul...

Страница 16: ...isas sembled once locked together Plan ahead to ensure the proper installation height is achieved with the se lected chimney components These firestop spacers are designed to provide the minimum two i...

Страница 17: ...dislodged the chimney section from the fire place or at any chimney joint Figure 15 Offset Return with Stabilizer 10 Mark the Exit Point of the Roof Locate the point where the chimney will exit the r...

Страница 18: ...e and into the hole at the midpoint of the fireplace side 18 Install the Glass Doors If desired or required by local building codes install the glass doors using the instructions supplied with the par...

Страница 19: ...y be used including brick stone veneer brick or standard siding materials In constructing the chase several factors must be considered a Maintain a 3 4 minimum air space around the fireplace b Maintai...

Страница 20: ...flashing section of pipe must extend above the top of the chase collar to allow installation of the storm collar and termination cap For installations utilizing a telescoping round termination cap TR...

Страница 21: ...he gas line to prevent cold air leakage A gas access hole is provided on the right hand side of the fireplace It is recommended that the piping be brought in from the right side However if it becomes...

Страница 22: ...ppliance 1 Pull the electrical wires from outside the appliance through this opening into the valve compartment 2 Loosen the two screws on the Romex connector feed the necessary length of wire through...

Страница 23: ...ments Awiring diagram is shown in Figure 25 b Optional Accessories Requirements Wiring for optional accessories should be done now to avoid reconstruction To install junction box please refer to the i...

Страница 24: ...e 28 It is not necessary to use all of the lava rock Save the remainder for future use 3 Place the Rock Wool Place approximately 1 2 diameter pieces of rock wool under the front logs on the bottom hea...

Страница 25: ...THE STANDING PILOT A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas B...

Страница 26: ...with doors fully open or fully closed If doors are left partially open gas and flame may be drawn out of the fireplace opening creating the risk of fire smoke or carbon monoxide 2 Negative Air Pressur...

Страница 27: ...safe distance from the appliance e s u a C n o i t u l o S e l b i s s o P 1 n o n o i t a s n e d n o C s s a l g e h t s A s n o i t a i r a v e r u t a r e p m e t d n a n o i t s u b m o c s a g...

Страница 28: ...e vent may cause the flames inside the appliance to lift or ghost a dangerous situation Inspect the flames after installation to ensure proper performance See Figure 32 If the vent configuration is co...

Страница 29: ...nel as shown in Figures 22 and 23 on page 21 2 Remove the top right log See Figure 35 3 For removal of the grate log assembly remove two screws one per side from the hearth pan See Figure 36 4 Lift up...

Страница 30: ...1 0 2 1 0 8 1 3 g o L e l d d i M t f e L 1 1 2 8 7 4 1 3 g o L t n o r F t f e L 1 2 2 8 5 4 2 3 k c o R a v a L l o o W l a r e n i M w o l G e r i F d n a e t i l u c i m r e V 1 3 2 3 3 3 4 1 l o...

Страница 31: ...21 Gas Pressure 22 Glass Doors 6 18 26 Grate 6 H Hearth Extension Finishing Materials 18 Positioning 18 Hearth Extensions 11 Hearth Strips 15 High Altitude Installation 21 I Insulation Shield 16 J Jun...

Страница 32: ...quate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those spe...

Отзывы: