8
4031-478 Rev i
11/04
NOVUS PLUS INSTALLATION INSTRUCTIONS
5. Wiring
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian
Electric Code CSA C22.1
.
Note:
Optional Accessories Requirement: Wiring for
optional accessories should be done now to avoid
reconstruction.
a.
Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 7.
2)
This appliance is equipped with an intermittent pilot control valve which operates on a 3 volt system.
3)
This appliance is supplied with a 3 volt AC transformer, which requires the installation of the supplied junction box. The
junction box must be installed at this time to avoid reconstruction.
WARNING!
This intermittent pilot ig-
nition appliance DOES re-
quire a 110VAC supply for
operation.
Figure 7 - Intermittent Pilot Ignition Wiring Diagram
CAUTION:
Label all wires prior to dis-
connection when servic-
ing controls. Wiring errors
can cause improper and
dangerous operation.
Verify proper operation
after servicing.
Note:
Accessory circulating
fans CANNOT be used with
the Novus Plus.