Heatilator NBV4236I-B Скачать руководство пользователя страница 18

18

Heatilator  •   NBV4236I-B, NBV4842I-B Owner’s Manual  •  2376-981 Rev. L  •  5/22  

Frequently Asked Questions and Troubleshooting 

A.  Frequently Asked Questions

Contact your dealer

 for additional information regarding operation and troubleshooting.  Visit www.heatilator.com to 

locate a dealer.

ISSUE

SOLUTIONS

 Condensation on the glass

This is a result of gas combustion and temperature variations. Prior to appliance being turned 

on, the inside of the glass has cooled below the dew point producing a byproduct of combus-

tion:  water in the form of condensation.  As the fireplace glass warms, the condensation will 

disappear. 

 

In the summer, the inside of your fireplace contains hot humid air from outdoors. When the air 

from outdoors contacts glass cooled below the dew point by your air conditioning, moisture in 

that air will condense.

 Blue flames

This is a result of normal operation and the flames will begin to yellow as the fireplace is 

allowed to burn for 20 to 40 minutes.

 Erratic flames

Verify that the glass assembly is correctly installed and that all glass latches are engaged over 

the tabs on the glass frame.

 Odor from fireplace

When first operated, this fireplace may release an odor for the first several hours. This is caused 

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor 

may also be released from finishing materials and adhesives used around the fireplace.  These 

circumstances may require additional curing related to the installation environment.

 Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned 

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing pro-

cess. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. 

Contact

 

your dealer.

 Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to 

the sound produced by a furnace or heating duct. This noise does not affect the operation or 

longevity of the fireplace.

Is it normal to see the pilot flame burn  

continually?

In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is 

turned off. Some optional control systems available with IPI models may allow pilot flame to 

remain lit.

Power Outages

(battery backup)

NBV-IFT appliances are not approved for use with battery backup. 

 

Do NOT operate 

this appliance with battery backup.  This appliance will not be protected by the high 

temp limit switch if battery backup is installed.  

Refer to Section 3 for more details.

Wall above appliance feels hot to   

 the touch.

No action necessary.  This appliance ships with a non-combustible material attached. Speci-

fications of the attached non-combustible material are listed in the Installer’s Manual for this 

appliance.

Содержание NBV4236I-B

Страница 1: ...ediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...z N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved Mi...

Страница 3: ...aintenance Frequency and Tasks 15 B Maintenance Tasks Homeowner 15 C Maintenance Tasks Qualified Service Technician 17 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 18...

Страница 4: ...ment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from...

Страница 5: ...ces such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the a...

Страница 6: ...men tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations 2 2 Product Specific Information Models U S or Canada Maximum Input BTU h M...

Страница 7: ...alone near a hot fireplace whether operating or cooling down Teach children to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more inf...

Страница 8: ...es above the center of the appliance at various heights above the appliance opening NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribed by the test stan...

Страница 9: ...l to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers maximum allowable...

Страница 10: ...leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly remo...

Страница 11: ...ly call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas...

Страница 12: ...with the fan I Appliance Break In Follow the initial break in procedure below to cure the materials used to manufacture the fireplace and the finishing materials around it The fireplace should be run...

Страница 13: ...er normal circumstances Multifunctional Wired Wall Switch Control System Locate the wired wall switch control module in control cavity Locate battery operation switch on the side of the module Slide t...

Страница 14: ...ttent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not be placed in the battery pa...

Страница 15: ...ed off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation trouble s...

Страница 16: ...freely and no obstructions are present Reinstall decorative front Decorative Barrier Fronts Frequency Annually By Homeowner Tools needed Protective gloves stable work surface Assess condition of scree...

Страница 17: ...ated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency...

Страница 18: ...nufacturing Odor may also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on...

Страница 19: ...ect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed incorrec...

Страница 20: ...rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod...

Страница 21: ...ructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with...

Страница 22: ...Service Parts Beginning Manufacturing Date Feb 2016 Ending Manufacturing Date Active Manufacturing Reactivation Date May 2022 Part number list on following page Log Set Assembly Novus Gas Fireplace B...

Страница 23: ...33 8 Dry Wall Lip 4031 207 9 Glass Shield 4031 219 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2382 111 12 Burner Assembly 2382 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Val...

Страница 24: ...133 8 Dry Wall Lip 4031 208 9 Glass Shield 4031 220 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2383 111 12 Burner Assembly 2383 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Va...

Страница 25: ...12 Y Pilot Assembly Propane 2090 013 Y 13 3 Gasket Pilot Assembly 4021 042 13 4 Air Shutter Assembly SRV4055 202 Y 13 5 Seal Plate Assembly 2382 584 13 6 Flex Ball Valve Assembly SRV302 320 Y 13 7 Val...

Страница 26: ...______________________________________________________________ ________________________________________________________________________________ ________________________________________________________...

Отзывы: