Heatilator MHST36D Скачать руководство пользователя страница 27

08/04

31068 Rev E

27

MHST36D INSTALLATION INSTRUCTIONS

Index

A

Air Clearance  16, 19
Air Kit  5, 18
Ashes, Disposal of  26
Attic Insulation Shield  16

B

Building Codes  4, 17, 21

C

Chimney

Checking the Assembly  16
Cleaning  26
Creosote  26
Height Requirements  13
Requirements  11
Securing the System  16

Chimney Bracket  7
Chimney Requirements  11
Chimney Sections

Assembling  15
Number Required  13

Cleaning  26
Codes

Building  4, 17, 21
Gas  19, 22

Combustible Material  20, 21
Components  5
Construction  20
Creosote  26

D

Damper  22
Description of the Fireplace System  4
Dimensions  6
Doors  5, 21, 23
Draft  24

E

Exhaust Products  9

F

Finishing  21
Fireplace

Enclosure  19
Locations  8

Firescreen  23
Firestop Spacer

Installation  15

Firewood  22, 23
Flue  22
Framing  10
Fuel  22, 23

G

Gas Codes  19, 22
Gas Knockout Location  6
Gas Log/Lighter Provisions  19
General Information  22
Glass Doors  5, 21, 23
Grate  5, 23

H

Hearth Extension  20

Positioning  21

I

Installation

Fireplace  14

Insulation Shield  16

J

Joint Band  7

L

Leveling the Fireplace  14
Locations  8

M

Mantel  11, 21
Mantels  11
Material, Sealant  21
Metal Hearth Strips  14
Moisture Content of Wood  22, 23

N

Negative Air Pressure  24
Noncombustible Material  21
Noncombustible Sealant Material  21

O

Offsets/Returns  12
Outside Air  22
Outside Air Kit  5, 18
Overhead Obstructions  12

P

Positioning  14

R

Roof Thimble  6, 17

S

Safety  14
Seasoning the Wood  24
Sidewalls/Surrounds  11
Smoke  9
Soot  26
Space Requirements  8
Standard for Decorative Gas Appli-

ances  19, 22

Starting a Fire  24
Surrounds  11

T

Ten Foot Rule  13
Termination Cap  7, 18
Termination Cap Cleaning  26
Typical Fireplace System  4

U

UL 127 Standards  4
Unvented Gas Log Heater  19, 22

V

Ventilation  24

W

Wet Insulation  2
Wood

Moisture of  22, 23
Seasoning of  24

Wood Fuel  22, 23

Содержание MHST36D

Страница 1: ...injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS MHST36D WO...

Страница 2: ...problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4 The f...

Страница 3: ...the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the firepla...

Страница 4: ...arances must be maintained at all times The illustrations and diagrams used throughout these installation instructions are not drawn to scale Figure 1 A Typical Fireplace System B DESCRIPTION OF THE F...

Страница 5: ...ral Grate Outside Air Kit and Hearth Protection Strips DM1036 Bi fold Glass Doors Black Finish DM1036B Bi fold Glass Doors Polished Brass Finish included with fireplace DM1036S Bi fold Glass Doors Sta...

Страница 6: ...g SL324 Chimney Section 24 in long SL336 Chimney Section 36 in long SL348 Chimney Section 48 in long SL315 Chimney Offset Return 15 deg SL330 Chimney Offset Return 30 deg JB877 Chimney Joint Band CB87...

Страница 7: ...ashing 6 12 to 12 12 Pitch RF371 Roof Flashing Flat to 6 12 Pitch CAK4A Chimney Air Kit Firestop Spacer Catalog A B FS338 0 deg 14 1 2 in FS339 15 deg 18 3 8 in FS340 30 deg 23 in Catalog A B SL306 6...

Страница 8: ...supply Figure 2 Fireplace Locations D PRE INSTALLATION PREPARATION 1 Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace This fi...

Страница 9: ...e precautions will reduce the possibility of fireplace smoking or air flow reversal WARNING To prevent contact with sagging or loose insulation the fireplace must not be installed against vapor barrie...

Страница 10: ...ST36D fireplace will fit a framed opening of 41 in wide x 42 in tall The finished cavity depth must be no less than 23 in Figure 3 shows a typical framing using 2 x 4 lumber of the fireplace assuming...

Страница 11: ...ded area E CHIMNEY REQUIREMENTS When planning your fireplace location the chimney construction and necessary clearances must be considered The fireplace system and chimney components have been tested...

Страница 12: ...measured from the base of fireplace to top of starter col lar 47 1 4 in Example Your A dimension from Figure 5 is 14 1 2 in Using Table 1 the dimension closest to but not less than 14 1 2 in is 14 5...

Страница 13: ...ntal distance from the side of the chimney to the peak of the roof is 10 ft or less the top of the chimney must be at least 2 ft above the peak of the roof but never less than 3 ft in overall height a...

Страница 14: ...instructions for framing on pages 8 11 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective Metal Hear...

Страница 15: ...op bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See Figure 8 5 Inst...

Страница 16: ...ney system a Bend the tabs at the top of the attic insulation shield inward This will help keep the chimney section centered in the shield b Position the shield over the vertical chimney section where...

Страница 17: ...n The extension should overlap the thimble one inch c To attach the extension to the thimble drill 1 8 in holes through the outer shield of the thimble using the predrilled holes in the extension as g...

Страница 18: ...wn 10 Install the Outside Air Kit The outside air kit is supplied as a standard feature with this fireplace and its use is required to minimize the effects of negative pressure within the structure It...

Страница 19: ...n this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure fire 13 Gas...

Страница 20: ...n must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are s...

Страница 21: ...of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electric RTV103 Black or equivale...

Страница 22: ...or Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas log he...

Страница 23: ...a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak hard...

Страница 24: ...wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process...

Страница 25: ...y is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of soot...

Страница 26: ...ed If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yoursel...

Страница 27: ...s Knockout Location 6 Gas Log Lighter Provisions 19 General Information 22 Glass Doors 5 21 23 Grate 5 23 H Hearth Extension 20 Positioning 21 I Installation Fireplace 14 Insulation Shield 16 J Joint...

Страница 28: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any oth...

Отзывы: