B. Construct the Appliance Chase
A chase is a vertical boxlike structure built to enclose the gas
appliance and/or its vent system. Vertical vents that run on
the outside of a building may be, but are not required to be,
installed inside a chase.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems. The
chase should not break the outside building envelope in any
manner.
Walls, ceiling, base plate and cantilever
fl
oor of the chase
should be insulated. Vapor and air in
fi
ltration barriers should
be installed in the chase as per regional codes for the rest of
the home. Additionally, in regions where cold air in
fi
ltration
may be an issue, the inside surfaces may be sheet rocked
and taped (or the use of an equivalent method) for maximum
air tightness.
To further prevent drafts, the
fi
restops should be caulked
with high temperature caulk to seal gaps. Gas line holes and
other openings should be caulked with high temperature
caulk or stuffed with unfaced insulation. If the appliance is
being installed on a cement slab, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
Fire Risk
• Construct chase to all clearance
speci
fi
cations in manual.
• Locate and install appliance to all
clearance speci
fi
cations in manual.