Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09
19
Measured from top of fireplace opening (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
4-5/8
6-1/4
7
7-3/4
8-1/2
9-1/4
10
10-3/4
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
16-3/4
30 in. minimum
to ceiling
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions
0 in. min.
to perpendicular wall
A
4-5/8 in. (117 mm) min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Mantels
Mantel Legs or Wall Projections