background image

September 14, 2015

7056-153C

Page  7

WS Series Wood Burner

DESCRIPTION

Default Flue Kit

Default Flue Kit-

With Flue Shield

A

Min. Clearance from back of unit to rear wall

300

100

B

Min. clearance from center of spigot to rear wall

468

268

C

Min. distance from front of base to 

fl

 oor protector front

300

300

D

Min. 

fl

 oor protector front width 

800

800

E

Min. distance from rear wall to front of 

fl

 oor protector

1291

1091

F

Min. distance from unit side to side wall

400

400

G

Min. clearance from center of spigot to side wall

730

730

FLOOR PROTECTOR

Heatilator WS22 does not require a insulating Floor Protector, as they are tested and comply with the 
minimum Floor Protector requirements of 

AS/NZS 2918:2001.

Note:

 The minimum Floor Protector sizes are speci

fi

 ed in the clearance chart, see Table 3 & 4.

 A Floor Protector can include ceramic tiles with grouted joints 

fi

 xed directly onto a wooden 

fl

 oor or 

a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a 
wooden 

fl

 oor.

 If installed directly onto a concrete slab, the concrete slab can be considered as the 

fl

 oor 

protector,but must maintain the minimum measurement listed.

NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to

AS/NZS 2198:2001 3.2.3 TABLE 3.1

Table 3

Fig. 7

FLOOR PROTECTOR

D

F

E

G

REAR WALL

SIDE W

ALL

PARALLEL POSITIONING

B

C

A

REAR W

ALL

Содержание Eco-Choice WS18-AU

Страница 1: ...ve For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to...

Страница 2: ...HAMOISTURECONTENTLESSTHEN25 dry basis WetbacksareNOTanapprovedoptionandmustnotbefitted Hearth HomeTechnologies 1445NorthHighway Colville WA 99114 UnitedStatesofAmerica OVERALLAVERAGEEFFICIENCY TESTEDT...

Страница 3: ...3 Side View 12 1 2 in 317mm 25 in 635mm C L 19 11 16 in 500 mm 21 11 16 in 550 mm 29 in 736 mm 14 13 16 in 376 mm 9 9 16 in 242 mm 13 13 16 in 350 mm 19 1 16 in 484 mm 9 5 16 in 236 mm 26 1 2 in 673m...

Страница 4: ...imum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can include ceramic tiles with grouted...

Страница 5: ...ont width 692 F Min overall floor protector depth 1379 Table 2 Fig 5 1 If a separate floor protector is being used position now Place the firebox on the floor protector to suit the minimum installatio...

Страница 6: ...e 6 3 Side View 26 in 660mm 13 in 330mm C L 9 9 16 in 243mm 13 13 16 in 351mm 34 in 864mm 9 13 16 in 249mm 19 1 16 in 484mm 14 13 16 in 376mm 19 5 8 in 499mm 21 11 16 in 551mm 11 5 8 in 295mm 6 5 8 in...

Страница 7: ...tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 3 4 A Floor Protector can inc...

Страница 8: ...floor protector front width 688 F Min overall floor protector depth 1377 Table 4 Fig 8 1 If a separate floor protector is being used position now Place the firebox on the floor protector to suit the...

Страница 9: ...Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the...

Страница 10: ...casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing...

Страница 11: ...of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD Cowl AS NZS2918 2001 Un...

Страница 12: ...ral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounted Shield...

Страница 13: ...ON IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MOD...

Страница 14: ...coverage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor which...

Страница 15: ...t supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 inte...

Страница 16: ...phone Notes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow thes...

Отзывы: