Appliance Set-up
A source of air (oxygen) is necessary in order for
combustion to take place. Whatever combustion air is
consumed by the fire must be replaced. Air is replaced via
air leakage around windows and under doors. In homes
that have tightly sealed doors and windows, an outside
air source is needed. An optional Outside Air system is
available.
Outside Air Installation Instructions
1.
Remove the Rear Outside Air Cover Plate on outer can
and discard and reuse 2 screws
(Figure 38.1)
.
2.
Install Front Outside Air Plate using 2 screws from
the Rear Plate. (This part is located in the component
pack)
3.
Ensure existing access hole in fireplace will not be
covered by the outer can. Existing outside air intake
hole may be under at the rear or side of outer can.
Outside air may also enter down existing chimney
chase in some situations.
4.
Install appliance.
Outside Air Kit Option
5. Remove the outside air cover plate B on outer can and
discard
(Figure 38.1)
.
6.
Install Front Outside Air Plate using 2 screws from
the Rear Plate. (This part is located in the component
pack)
7.
Install optional flex adapter to outer can with the same
screws. Do not use plastic wire ties that come with the
kit as they will melt.
Optional Outside
Air Venting Kit
OAK-ACC
Rear Outside Air Cover Plate
Front Outside Air Cover Plate
A. Outside Air Kit Installation
Figure 38.1
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or chimneys
Fumes or odor may result
WARNING
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
•
Leaves
•
Snow or ice
•
Other debris
Block may cause combustion air starvation.
Smoke spillage may set off alarms or irritate
sensitive individuals.
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaust flue.
•
Fire will not burn properly
•
Smoke spillage occurs when door is opened
due to air starvation.
WARNING
NOTE:
You may need to install the flex pipe into the
firebox first depending on installation. Attach flex
to adapter with at least 2 screws.
8.
Ensure existing access hole in fireplace is sufficient to
feed the 4 inch flex.
9.
After sliding can into fireplace, feed flex into cut
opening to obtain outside combustion air.
10.
Install appliance.