background image

7057-128K • October 24, 2018

33

ECO-ADV-WS22

www.heatilatorecochoice.com

Recommended 

Location 

Marginal 

Location 

Location 

Not 

Recommended 

 

Recommended 

Location 

 

Location NOT 

Recommended 

Multi-level Roofs 

Windward 

Leeward 

Outside Air Kit Termination Cap

Figure 33.1

A. Locating Your Appliance & Chimney

Location of the appliance and chimney will affect 

performance. As shown in 

Figure 33.1 

the chimney should:

•  Install through the warm space enclosed by the building 

envelope. This helps to produce more draft, especially 

during lighting and die down of the fire.

•  Penetrate the highest part of the roof. This minimizes 

the affects of wind turbulence and down drafts.

• 

Consider the appliance location in order to avoid floor 

and ceiling attic joists and rafters.

•  Locate termination cap away from trees, adjacent 

structures, uneven roof lines and other obstructions.

Your local dealer is the expert in your geographic area and 

can usually make suggestions or discover solutions that will 

easily correct your flue problem.

Chimney Systems

Содержание ECO CHOICE ECO-ADV-WS22

Страница 1: ...pliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comp...

Страница 2: ...lafond et des murs de la maison mobile doit tre maintenue intacte L appareil de chauffage doit tre fix la charpente de la maison mobile Les composants requis pour l installation des maisons mobiles As...

Страница 3: ...E Baffle Removal 25 F Tube Channel Assembly Replacement 26 Install Guide 6 Getting Started 27 A Design and Installation Considerations 27 B Fire Safety 27 C Negative Pressure 28 D Tools And Supplies...

Страница 4: ...or refunding the verified purchase price of the product itself The maximum amount recoverable under this warranty is limited to the purchaser price of the product This warranty is subject to condition...

Страница 5: ...fting caused by tightly sealed constructions insufficient make up air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specif...

Страница 6: ...Split Wood LOAD WOOD ADD NEWSPAPER ADD MORE WOOD 4 ADD KINDLING LIGHT THE PAPER HIGH LOW OPEN AIR CONTROL HIGH LOW REDUCE AIR CONTROL Set to desired heat output 5 WARNING Risk of Fire Close and secure...

Страница 7: ...umber and data collected during EPA emissions test Weighted average HHV efficiency using Douglas Fir dimensional lumber and data collected during EPA emissions test A range of BTU outputs based on EPA...

Страница 8: ...y responsibility for and the warranty will be voided by the following actions WARNING This product and the fuels used to operate this product wood and the products of combustion of such fuels can expo...

Страница 9: ...ARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children a...

Страница 10: ...include one or more of the following Chimney connector or appliance glowing Roaring rumbling noises Loud cracking or banging sounds Metal warping Chimney fire 2 What To Do if Your Appliance is Over Fi...

Страница 11: ...the flames be maintained and not allowed to go out This will ensure the cleanest possible fire If the flames tend to go out it is set too low for your burning conditions The air control located at the...

Страница 12: ...ance Leave the blower off until the burn is well established i e 30 minutes After loading the appliance with wood and starting the fire set the Burn Rate Air Controls to the desired setting by followi...

Страница 13: ...fire Stack the pieces of wood 1 2 inch to 1 inch apart near enough to keep each other hot but far enough away from each other to allow air flow between them 7 Once there is an established bed of coals...

Страница 14: ...Board MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket The baffle boards are FRAGILE Use extr...

Страница 15: ...etely Processed Solid Fuel Fire Logs NOT permitted for use in this appliance Hardwood vs Softwood Your appliance performance depends on the quality of the firewood you use Seasoned wood contains about...

Страница 16: ...e rheostat on then adjusting back towards OFF as far as possible without turning the blower off For a low blower speed turn the control knob clockwise as far as possible NOTE For burn settings 3 to 5...

Страница 17: ...Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks To minimize the effects of negative air pressure Install the outside air kit with the...

Страница 18: ...driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible death ISSUES SOLUTIONS Odor from appliance When first operated this appliance may release an...

Страница 19: ...ockage and creosote build up Firebrick Ash Removal WEEKLY or After Every 25 Loads of Wood Ashes must be cool before you can dispose of the ashes in a non combustible container Firebrick is designed to...

Страница 20: ...combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a newly started or a slow burning fire As a result creosote residue accumulates on t...

Страница 21: ...smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated...

Страница 22: ...refer to Building a Fire Section Check for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wo...

Страница 23: ...by impact or misuse WARNING Injury Risk Use only glass specified in manual DO NOT REPLACE with any other material Handle glass assembly with care When cleaning glass Glass Assembly CAUTION Avoid stri...

Страница 24: ...5 Push the snap disc and spade connectors back inside bracket and re attach the bracket to the appliance Snap Disc Location C Snap Disc Replacement Figure 24 3 Figure 24 2 D Door Handle Assembly CAUT...

Страница 25: ...ic blanket still in place slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece 5 Remove the ceramic blanket 6 Re install...

Страница 26: ...ement NOTE Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them Replacing Tube Channel Assembly 5 Slide the tube channel assembly into side of firebox and insert ea...

Страница 27: ...trictions installation inspection and permits CAUTION Notice Hearth Home Technologies assumes no responsibility for the improper performance of the appliance system caused by Inadequate draft due to e...

Страница 28: ...e strongest in lower levels of the house Causes include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water appliances and other combustion appliances Clothes drye...

Страница 29: ...e under the appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file...

Страница 30: ...9 1 16 in 484mm 14 13 16 in 376mm 19 5 8 in 499mm 21 11 16 in 551mm 11 5 8 in 295mm 6 5 8 in 168mm 15 1 8 in 384mm 30 3 4 in 781mm 28 3 8 in 720mm 27 1 2 in 699mm 23 1 4 in 591mm 27 in 686mm C L Figur...

Страница 31: ...ed High temperatures or hot embers may ignite concealed combustibles Figure 31 1 Figure 31 4 Figure 31 3 Figure 31 2 Figure 31 5 Figure 31 6 Corner hearth pad dimensions with single wall pipe Corner h...

Страница 32: ...1245 10 254 For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum depth of Alcove shall be no...

Страница 33: ...hrough the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the a...

Страница 34: ...e sea level and or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney...

Страница 35: ...T 2100o F or ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for...

Страница 36: ...round windows and under doors In homes that have tightly sealed doors and windows an outside air source is highly recommended An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex...

Страница 37: ...ed control for this appliance is adjusted at the factory and normally does not require further adjustment NOTE When the speed control is turned clockwise it will click on to high speed Continue to tur...

Страница 38: ...4 The factory built fireplace must meet UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full leng...

Страница 39: ...7057 128K October 24 2018 39 ECO ADV WS22 www heatilatorecochoice com 11 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service...

Страница 40: ...7057 128K October 24 2018 40 ECO ADV WS22 www heatilatorecochoice com Date of Service Performed By Description of Service...

Страница 41: ...2 www heatilatorecochoice com Service Parts Beginning Manufacturing Date Mar 2010 Ending Manufacturing Date Active Part number list on following page Free Standing Wood Stove ECO ADV WS22 1 2 3 4 5 6...

Страница 42: ...SRV7056 147 7 Retainers Tube Support SRV7057 118 8 Pedestal Assembly SRV7057 005 9 OA Cover Plate SRV7044 217 10 Side Panel Right SRV7057 008 11 Tube Channel Cover SRV7057 122 12 Tube Channel Assembly...

Страница 43: ...Magnet Round SRV7000 140 Y Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness 7033 262 Component Pack Stove SRV7057 006 Contains Screws Handle Spring Hand...

Страница 44: ...installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership pur...

Отзывы: