Heatilator CKVN Скачать руководство пользователя страница 14

26678 Rev H

14

02-02

GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT

G.  OPERATING INSTRUCTIONS

1. This gas appliance has a manual ignition device that

lights  the  pilot.  When  lighting  the  pilot,  follow  these

instructions exactly.

2. STOP! BEFORE READING FURTHER, smell around

the appliance area for gas. Be sure to smell next to

the  floor  because  some  gas  is  heavier  than  air  and

will settle to the floor.

3. WHAT TO DO IF YOU SMELL GAS:

•

Do not try to light the appliance.

•

Do not touch any electrical switch; do not use any

telephone in your building.

•

Immediately  call  your  gas  supplier  from  a

neighbor’s  telephone.  Follow  the  instructions  of

your utility.

•

If  you  cannot  reach  your  utility,  call  the  fire

department.

4. If the pilot light and burner went out during use, you

must take the glass off the appliance and wait to clear

out any gas. Follow the lighting instructions below.

5. Use only your hand to push in or turn the gas control

knob to light the pilot. Never use tools. If the knob will

not push in or turn by hand, do not try to repair it; call a

qualified service technician. Using a tool or attempting

repairs may result in a fire or explosion.

6. Do not use this appliance if any part has been under

water. Immediately call a qualified service technician

to inspect the appliance and to replace any part of the

control  system  and  any  gas  control  that  has  been

under water.

1. STOP! Read the safety information above.
2. Turn  off  all  electric  power  to  the  appliance.  If  your

appliance has a thermostat, set to lowest setting.

3. Open control access panel.
4. Find  the  pilot.  The  pilot  is  inside  the  combustion

chamber next to the main burner.

5. If the gas control knob is at the “OFF” position, go to

step 7. If the gas control knob is at the “ON” position,

go to step 6.

another five minutes or until the gas odor is no longer

present before continuing. If the odor of gas does not

disappear after fifteen minutes, STOP! Follow “B” in

the safety information above.

8. Replace glass panel if it has been removed.
9. Turn gas control knob counterclockwise to the “PILOT”

position.

10. Push the gas control knob in all the way and hold. At

the  same  time,  push  in  the  red  ignition  button

repeatedly  until  the  pilot  lights.  Never  hold  the  gas

control knob in for more than ten seconds if the pilot

does not light. Once the pilot lights, continue to hold

the gas control knob in for 15 seconds. Release the

gas control knob and it will pop back up. If pilot does

not remain lit, repeat steps 6 through 9.
If  gas  control  knob  does  not  pop  back  up  when

released, turn the knob to “OFF” and call your service

technician  or  gas  supplier.
If the pilot will not stay on after two attempts, turn the

gas  control  knob  to  “OFF”  and  call  your  service

technician  or  gas  supplier.

11. Turn  gas  control  knob  couterclockwise  to  the  “ON”

position. The knob can be turned to the “ON” position

only if it is popped out.

12. Close  the  access  panel.
13. Turn on electrical power to the appliance. If equipped

with a thermostat, set to the desired setting.

LIGHTING  INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

6. If the pilot light went out during normal use with the

gas  control  knob  at  the  “ON”  position,  turn  the  gas

control  knob  to  the  “OFF”  position.  REMOVE  THE

FIXED GLASS PANEL. Wait ten minutes to clear out

any gas.

7. Smell  for  gas,  including  near  the  floor.  If  you  don’t

smell gas, go to the next step. If you smell gas, wait

TO TURN OFF GAS TO APPLIANCE

1. Turn rocker switch to “OFF” or the wall thermostat to

lowest setting if your appliance is so equipped.

2. Turn off all electric power to the appliance if service is

to be performed.

3. Open control access panel.
4. Turn gas control clockwise to “OFF”.
5. Close  control  access  panel.

f i r e - p a r t s . c o m

All manuals and user guides at all-guides.com

Содержание CKVN

Страница 1: ...e information in this manual is not followed exactly a fire or explosion may result causing property damage personal in jury or loss of life Do not store or use gasoline or other flammable vapors and...

Страница 2: ...abel of this gas appliance 7 The appliance area shall be kept clear and free from combustible materials gasoline and other flammable vapors and liquids 8 While servicing this appliance always shut off...

Страница 3: ...2848 HEATILATOR is a registered trademark of Hearth Technologies Inc HTI a division of HON INDUSTRIES B DESCRIPTION OF THE SYSTEM The GBi25 Series is a B vent gas fired room heater Combustion air is s...

Страница 4: ...n u o r r u S m u i d e M 6 4 D S G m i r T h t i W W 6 4 x H 3 3 d n u o r r u S e g r a L P V K C s a G e n a p o r P o t t i K n o i s r e v n o C N V K C s a G l a r u t a N o t t i K n o i s r e...

Страница 5: ...r hose A 1 8 NPT plugged tapping is provided on the gas control valve near the outlet to the main burner immediately upstream of the gas supply connection to the appliance accessible for a test gauge...

Страница 6: ...se of the appliance must be maintined The horizontal run must not exceed 50 of the vertical height Maximum vertical venting height is 40 above the base of the appliance The vent termination must be in...

Страница 7: ...d lift out See Figure 3 Handle the glass frame with care to avoid striking or scratching it on hard objects or slamming it shut Remove the two screws on the baffle as shown in Figure 4 To remove the d...

Страница 8: ...ds For Model GSD24 the bend tab is located on the top of the right surround side For Models GSD40 and GSD46 the bend tab is located on the right side of the top surround Use a pair of pliers to bend t...

Страница 9: ...ock hazard and should be plugged directly into a prop erly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Figure 11 Installation of Hood Figure 12 Assemble Bra...

Страница 10: ...ier Be careful not to over tighten Note Placement of the rock wool should be done with care and time as this will create the look of the fire when burning WARNING Never operate this appliance with the...

Страница 11: ...l Figure 22 Firebox Bottom Removal Figure 23 Fan Removal i Fan Access 1 Disconnect the power cord or turn off the circuit breaker before removing the fan Remove the firebox bottom following directions...

Страница 12: ...in the ab sence of local codes with National Electric Code ANSI NFPA 70 latest edition This appliance can be used with a thermostat CAUTION Label all wires prior to disconnection when servicing contr...

Страница 13: ...llivolt thermostat is allowed It must be located within 20 feet of the appliance Figure 25 shows how to connect the thermostat Remove ON OFF switch wires from valve Place thermostat wires to the posts...

Страница 14: ...five minutes or until the gas odor is no longer present before continuing If the odor of gas does not disappear after fifteen minutes STOP Follow B in the safety information above 8 Replace glass pane...

Страница 15: ...floating The flame color should be blue with yellow tips The thermopile tip should be covered with flame See Figures 26 and 27 If the vent configuration is installed incorrectly the vent may cause the...

Страница 16: ...the event of glass breakage follow glass removal instructions This will allow the removal of all glass fragments and sheet metal edge protection strips Vacuum all remaining glass pieces with a shop va...

Страница 17: ...u b d e g g u l P e g a k c o l b e v o m e r e c i f i r o r e n r u b k c e h C D e l i p o m r e h t e v i t c e f e D e l i p o m r e h t e c a l p e R E e c i f i r o n o t o n r e n r u B e c i...

Страница 18: ...P N O I T P I R C S E D 1 5 7 6 6 2 r e n r u B 2 3 1 6 0 2 r e w o l B r o f h c t i w S d e e p S e l b a i r a V 3 1 7 6 6 2 y l b m e s s A r e w o l B 4 8 9 9 3 2 t a t s o m r e h T M E T I T R...

Страница 19: ...1 1 5 6 2 d o o H d n u o r r u S 0 4 4 2 D S G d o o H d n u o r r u S 6 4 D S G 9 5 6 7 1 2 6 6 7 1 2 7 6 7 1 2 m i r T t f e L 4 2 D S G m i r T t f e L 0 4 D S G m i r T t f e L 6 4 D S G 0 1 7 7...

Страница 20: ...26678 Rev H 20 02 02 GBI25 SERIES B VENT GAS FIRED FIREPLACE INSERT HOMEOWNER S NOTES fire parts com All manuals and user guides at all guides com...

Страница 21: ...02 02 21 26678 Rev H GBI25 SERIES B VENT GAS FIRED FIREPLACE INSERT HOMEOWNER S NOTES fire parts com All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 22: ...26678 Rev H 22 02 02 GBI25 SERIES B VENT GAS FIRED FIREPLACE INSERT HOMEOWNER S NOTES fire parts com All manuals and user guides at all guides com...

Страница 23: ...uel 3 G Gas Line 6 Gas Pressure 5 Gas Valve 10 Glass Frame 7 H High Altitude Installation 5 Hood 9 I Installation Instructions 6 L Lighting Instructions 14 Listings and CodeAprovals 3 Local Codes 3 M...

Страница 24: ...caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instru...

Отзывы: