Heatilator • Caliber Multi-Sided Direct Vent • 4002-079 Rev K • 11/07
D. Standing Pilot Ignition System Wiring
• This standing pilot ignition system wiring does not require
a 110 VAC supply to operate.
• It is recommended that a 110 VAC junction box be installed
with a switched outlet for the optional electric ember light
kit and an always-powered outlet for the optional remote
control. See Figure 10.3.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
CAUTION
Shock Risk
• Replace damaged wire with type 105° C
rated wire.
• Wire must have high temperature
insulation.
WARNING
Ignitor
Flame
Sensor
Pilot Assembly
GRN
ORG
BLK
ORG
Control
Box
To
Junction
Box
Battery
Pack
3V
Adapter
BLK
BRN
RED
RED
WHT
Optional
SPST Wall Switch
or
Optional Remote
Valve
WHT
+
-
+
-
WHT
RED
GRN*
* GRN wire only for
use with optional
wall switch
WSK-MLT
Figure 10.2 Intelli
¿
re Pilot Ignition (IPI) Wiring Diagram
Pilot
Ignitor
GAS
VALVE
To Burner
Gas Inlet
Inlet Tap
ORG
TAN
Thermopile
WHT
RED
BRN
Thermocouple
Copper
Tubing
Push
Button
Ignitor
Outlet Tap
Wall Switch (or
thermostat if
heater-listed)
WHT
RED
GRN*
Figure 10.3 Standing Pilot Ignition Wiring Diagram
Note:
Do not wire 110V to the millivolt valve (standing pilot)!
This will damage the valve.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
¨