Motion Sensor Quartz
Security Light
Requirements
• The light control requires 120-volts AC.
• This fixture is designed for wall mounting only.
• If you want to use Manual Mode, the control must be
wired through a switch.
•
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.
®
This package includes:
1 Light control
1 Gasket
1 Halogen Bulb
1 S-hook
6 Screws (3 sizes)
3 Wire connectors
Additional Items needed:
• Screwdriver
• Pliers to tighten locknut
• Ladder
Operating Instructions & Parts Manual
2LBN2
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 500 Watts Maximum In-
candescent
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement Lamp . . T3 500 Watt (or less) halogen
120 VAC
D
ual
B
rite
®
Timer . . . . OFF, 3, 6 hours, Dusk-to-Dawn
598-1114-04
HEA 010
Printed in China
09/07
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or main-
tain the product described. Protect yourself and others by observing all safety information. Failure to comply
could result in personal injury and/or property damage! Save these instructions for future reference.
NOTE: D
ual
Z
one
™ adds a zone of detection under
the motion sensor. D
ual
Z
one
™ requires no additional
adjustment and operates in conjuction with the for-
ward-looking sensor.