background image

3

595-5498-09

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Avoid aiming the control at:

•  Objects that change temperature rapidly, such as 

heat-

ing vents or air conditioners. These heat sources 
could cause false triggering.

•  Areas where 

pets or traffic may trigger the control.

•  

Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.

110°

30 ft (9.1m)

The detector is less sensitive to motion directly towards 
it and more sensitive to across motion. 

 7ft
 (2.1 m)

 

Maximum Range 

Maximum

 

 

Coverage Angle

  Rotate the sensor base left 

and right to aim the sensor. 
Adjust  the  sensor  eye  up 
and down to obtain desired 
coverage range.

  Walk  through  the  coverage 

area  noting  where  you  are 
when the lights turn on. Move 
the  sensor  head  up,  down, 
or  sideways  to  change  the 
coverage area.

  Set SENSITIVITY as needed. 

Too  much  sensitivity  may 
increase false triggering.

  Set  the  amount  of TIME  the 

lights stay on after motion is de-
tected (1, 5, or 10 minutes).

In the test position shown above, the light will turn 
on for 5 seconds each time motion is detected
 dur-
ing both daylight and darkness.

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-

candescent

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST,  AUTO  and  MANUAL 

OVERRIDE

Time Delay  . . . . . . . . . . 1, 5, 10 minutes
Sensitivity  . . . . . . . . . . . Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

ON-TIME

SENS

TEST 1 5 10

MIN  MAX

Bottom of Sensor

 

Least Sensitive 

Most Sensitive

Sensor

Motion

Motion

NOTE:  Sensor has a 1 

1

/

2

 minute calibration period 

before it will detect motion. When first turned 
on, wait 1 

1

/

2

 minutes. 

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

  For aiming, turn the SENSITIVITY (SENS) control 

to the mid position and the ON-TIME control to the 
TEST position.