![Heath Zenith 616283 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/heath-zenith/616283/616283_installation-and-operating-instructions-manual_2116705006.webp)
6
207738-01
TEST 1 5 10 MIN
OFF 3 6 DUSK TO
HOUR DAWN
Junction
Box
MOUNTING THE LIGHT FIXTURE
1. Make sure wire connectors and wires are inside the
junction box.
2. Slide the fixture assembly onto the mounting screws.
Tighten decorative nuts removed in step 1 of Light
Fixture Installation section securely against fixture base.
Mounting Screw
Decorative Nut
3. Install one medium base light bulb (60 Watt maximum,
tungsten incandescent). See Bulb Replacement section for
bulb installation.
TESTING AND ADJUSTMENTS
Initial Setup
The TEST mode overrides the photocell (daylight shutoff
feature) and allows the light fixture to be tested day or night
when the ON-TIME switch is in the TEST position. The
light will stay on for 5 seconds after all motion has stopped.
30 ft . (9 .1 m)
6 ft . (1 .8 m)
180°
Caulking Around Fixture Base
1. Turn the DualBrite control to OFF.
2. Set the ON-TIME control to TEST.
3. Turn on the circuit breaker or fuse and the light switch.
4. Allow the sensor to completely warm up (90 seconds)
before beginning the setup process.
5. Perform a walk test. Walk in an arc across the front of
the sensor.
Final Setup
1. Adjust the sensitivity (SENS) to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage area
(see Testing and Adjustments or Troubleshooting section).
2. Set the amount of ON-TIME you want the light to
stay on after motion is detected (1, 5, or 10 minutes).
3. Caulk around fixture base with silicone weather seal-
ant after all Testing and Adjustments are complete.
Sensor Controls
Maximum Range
Maximum
Coverage Angle
(Top View)