58
Long Range Scanning
The RMLD-CS can detect leaks from up to 100 ft. away. Actual distance may vary due to target surface and
environmental conditions. As the scanning distance is increased, the laser light level returned will
decrease. As the maximum distance is approached, a
“low
return
signal”
tone is heard. You will need to
move in closer.
For best results when scanning at distances greater than 50 feet, it is important to slow down the scanning
rate and take care in pointing the laser. When taking aim, use the spotter laser or the camera feature to
ensure proper scanning of the target area.
Be aware of the ground elevation. Scanning across the top of a knoll or past the edge of a structure can
result in beam skips (a sudden change in distance) which may give you a false detection.
Obstructions or variations in the lan
dscape can cause dark zones where the laser doesn’t scan. Look
for the best angle to thoroughly scan these areas. Scanning up a hillside may cause beam skipping or
dark zones around the foundation of a structure.