background image

Instructions

GB

5764H002 Ed.01

3

5

5

7

6

4

0

0

2 R
EV

.0

0 2
0

2

0

AKO ELECTROMECÁNICA 

, S.A.L.

Avda. 

Roquetes, 30-38

08812 

 Sant Pere de Ribes.

Barcelona 

 Spain.

Tel.: +34 902 333 145

Fax: +34 938 934 054

www.ako.com

We 

reserve the 

right to 

supply materials 

that might 

vary 

slightly to 

those 

described in 

our Technical 

Sheets. 

Updated information 

is av

ailable on 

our 

website.

General warnings

-Using the unit without observing the manufacturer's instructions may alter the appliance's safety requirements. 

-  Detectors  should  be  installed  in  a  place  protected  from  vibrations,  water  and  corrosive  gases,  where  the  ambient 

temperature does not exceed the value indicated in the technical data. 

-  Detectors  supervise  a  point  and  not  an  area.  If  the  gas  leak  does  not  reach  the  sensor,  or  the  level  of 

concentration  in  that  point  does  not  reach  the  alarm  values,  no  alarm  will  be  activated.  If  perimeter 
supervision is required, several sensors should be installed around that area.

Working conditions:

-Keep the detector work environment free of chemical agents (such as solvent, paints, alcohol, acetone, silicone, etc.), and 

free of engine fumes or gases from fermentations (bread, pizza) or ripening (breathing) of fruits.

-The detector should generally be installed in an area of potential concentration/accumulation of gas, in low positions (due 

to the greater relative density, in relation to air, of the gases subject to detection).

-The 

AKO-576410 / 576032

 refrigerant gas detector may only be used in locations that have not been classified with risk 

of explosion. 

-Reference regulations: EN 378
-Applicable local regulations: Compliance must be ensured 

Technical specifications

Power supply ...............................................................................................................................................................12-30 Vdc
Consumption........................................................................................................................... Typical: 75 mA, Maximum:150 mA
Alarm relay .........................................................................................................................................SPDT 30 Vdc, 2A,  cos 

j

 =1

Working ambient temperature....................................................................................................................................-20 to 50 ºC
Storage ambient temperature.....................................................................................................................................-20 to 60 ºC
Range of moisture permitted...................................................................................................0 - 95 % RH (Without condensation)
Protection degree With cable entry using cable gland .............................................................................................................IP68
 

With cable entry from the back ...................................................................................................................IP40

Dimensions ..........................................................................................................................107 mm (W) x 85 mm (H) x 39 mm (D)
Complies with the  EN 14624 standard.

Installation

2

1

Opción B

Fixed by screws

36 mm

70 mm

3

1

2

With cable entry using cable gland

3

.3

3

.1

3

.2

Option A

Fixied by an
adhesive

4

3

x2

Ø 2,8 mm

Ø 5 mm

x2

+

Connect following the
diagrams

Carefully perforate the rear entry so as not to damage 
the electronic board. 

This option involves changing from IP68 to IP40.

If the cable entry at the 
back has not been drilled, 
this option provides the 

IP68

 rating.

AKO-576410 

AKO-576032

Отзывы: