background image

icon and its SET temperature.   

For  the  sake  of  its  use  simplicity,  Heatermate  comes  with  Automatic  Mode  disabled.  To  enable  it,  please  refer  to  Section  6 

(Factory Settings): at No. 9 in the Table change 01 to 00 by pressing Down button, then press SET to save. The Automatic Mode 

is now enabled. Use short press of SET button to switch between Manual and Automatic Modes. 

Explanation 

Screen 

Press/hold “

” for 3 seconds then release - screen will 

display

  (6 periods for every week day) and week days: 

”. First period will be flashing - press “

” or “   ”to adjust 

temperature setting temperature then press “

” to adjust time setting. Press 

”to go to the next period and so on for all 6 periods for week days. Now press 

” to go to weekend programming with 2 periods for “

” and set 

temperatures and 

times in the same way as for week days. . Press “

” when 

finished. Please refer to the table below for default values for different periods.

 

 

 

5) Factory Programmed Periods and Settings 

Period

 

Icon

 

Default Time

 

Default Temperature

 

Working Day

 

1

 

 

06:00

 

20ºC

 

2

 

 

08:00

 

15ºC

 

3

 

 

11:30

 

15ºC

 

4

 

 

12:30

 

15ºC

 

5

 

 

17:30

 

20ºC

 

6

 

 

22:00

 

15ºC

 

Weekend

 

1

 

 

08:00

 

20ºC

 

2

 

 

23:00

 

15ºC

 

Example: Set  the heater  to come  ON  at 7pm, maintain  room temperature at  20  degrees  until 7am, then  turn  OFF  until  1pm,   

then at 1 pm to come ON and maintain 22 degrees temperature until 2.30pm, then turn OFF and come ON at 7pm (as above) 

and so on, during weekdays:   

(i) Set up Period 1 temperature to well below the typical room temperature e.g. to 10 degrees and Period 1 start time to 07:00; 

(ii) Move to period 2 and set its temperature also to 10 degrees and leave its start time as default at 08:00 (iii) Repeat the same 

for period 3 (iv) Move on to period 4 and set its temperature to 22 degrees and its start time to 13.00; (v) Move on to Period 5 

and set its temperature to 10 degrees and its start time as 14.30 (vi) Move on to Period 6 and set its temperature to 20 degrees 

and its start time to 19.00; (vii) Make sure the Timer function is disabled 

– 00.00 is set for both ON and OFF times (viii) Make 

sure Heatermate is in Automatic mode -        symbol is showing next to SET temperature. If not, press SET button once to switch 

to Automatic mode. You can now leave your Heatermate plugged in and it will do the job. 

 

 

6) Factory Settings

 

This  section  shows  how  to  change  the  factory  settings  according  to  your  requirements,  such  as:  enable  Automatic 

Mode, adjust the temperature sensor reading, change the temperature differential to activate your heater (see Section 1 

- Operation), change from Heating to Cooling Mode etc. 

Press/hold 

“ ” for 3 seconds then release to enter into factory settings mode, then press“

”to choose the required 

option (A1-A9, AA) as per table below. P

ress“ ” or “ ”to adjust value. Press“

” to save and move to the next option. 

Press Power to exit or wait 12 seconds for Factory Setting programming to time out. 

No. 

Display 

Setting Option 

Data Setting Function 

Factory Default 

Setting 

A1 

Room Ventilation Function 

(Heater is off when window is open) 

5-25ºC; 5-60min 

Disabled (- - ºC) 

A2 

Temperature Differential to Activate 

Heater 

1-9ºC 

2ºC 

A3 

Temperature Setting - Highest Limit 

20-70ºC 

35ºC 

A4 

Temperature Setting - Lowest Limit 

1-10ºC 

5ºC 

A5 

Temperature Sensor Calibration 

±5ºC 

Factory Calibration 

A6 

Anti-freezing Function 

– turns heater ON 

when temperature is below 5ºC 

00:Anti-freezing function OFF 

01:Anti-freezing function ON 

00:Anti-freezing 

function OFF 

A7 

Resume operation after power 

disconnection or stay OFF 

01:Resume operation 

00:Stay OFF   

01:Resume operation   

A8 

Operational Mode 

00:Cooling Mode 

01:Heating Mode 

01:Heating Mode 

A9 

Automatic Mode (AM) 

– weekly 

programming 

00: AM is enabled 

01: AM is disabled 

01: AM is disabled 

10 

AA 

Return to Factory Settings 

88:Do  not  return  to  Factory 

Settings 

00:Return to Factory Settings 

N/A 

Troubleshooting

Problem

Can’t turn the unit ON - display remains blank. 

Solution

: with Heatermate plugged into power 

do a firm but short press (pressing and holding even a little will not work) on the Power button 

– the display will come up. 

TECHNICAL SPECIFICATIONS: 

Operating Voltage: 240V , 50HZ   

Max Load: 10A, 2400W (resistive) 

Temperature Measurement Precision:±1ºC                                   

Temperature Setting Range:1ºC - 70ºC 

Self-consumption Power:<0.3W                           

Temperature Sensor: NTC 