Purpose                                                                   

目的

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Standard Design Conditions

                                     

标准设计工况

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

Recommended Placement and Clearance                

建议安装位置和间距

 

 
Some general rules for evaporator placement shall be followed:  

冷风机得布置规则如下:

 

 
 
 
 
 
 
 
 
 
 
 

These Heavy Duty Evaporator ranges are standard 
OEM products of Heatcraft Australia; they comprise 
both ‘medium’ and ‘low’ temperature ranges. They are 
intended for typical commercial sized cool room and 
freezer applications for the storage of vegetables, fresh 
meat, general foodstuffs, beverages, etc. They are not 
intended for environments that may have harmful, 
corrosive or flammable atmospheres or for the storage 
of corrosive or flammable chemicals. ‘Marine’ 
environments are considered corrosive; please consult 
Heatcraft before installing in this environment. 

这些工业型冷风机是西克标准的

OEM

产品;

包括中温和低温两个应用范围。专为保存蔬
菜,鲜肉,常规食品和饮料等典型的商业冷藏
及冷冻库而设计。不能用于储藏有害,腐蚀,
易燃物的冷库,也不能用于储藏腐蚀,易燃化
学品的冷库。海洋环境是有腐蚀的;如果要安
装在这样的环境中请在安装前咨询西克。

 

Medium temperature range evaporators (Kirby KHDC 
series) are designed at -4°C saturation suction 
temperature (SST) and 6 KTD to suit room temperature 
from -6°C to +20°C (refer to technical data for 
maximum and minimum allowed KTD for specific SST), 
for use in ‘heavy duty’ commercial cool room 
applications. For rooms below 2°C, additional 
defrosting means may be required.  R507/R404A and 
R22 are recommended refrigerants. For other 
refrigerants, please refer to sales data sheet for 
capacity variations. 
 
Low temperature range evaporators (Kirby KHDF 
series) are designed at -24°C SST and 6 KTD to suit 
room temperatures from –4°C to –32°C (refer to 
technical data for maximum and minimum allowed KTD 
for specific SST), for use in ‘heavy duty’ commercial 
freezer room applications.  R507 or R404A are the 
recommended refrigerants.  For other refrigerants, 
please refer to sales data sheet for capacity variations.  
For lower temperatures design variations may be 
required. 
 

中温工业型冷风机

(BOHN BHDC

系列)其设

计的饱和吸气温度为

-4°C

,温差为

6K

,适用

于室温从

-6°C

20°C

商用冷库(特定的饱和

吸气温度下允许的最大和最小温差请参照技术
资料)。室温低于

2 °C

时需额外的除霜方

法 。 该 蒸 发 器 推 荐 使 用 的 制 冷 剂 有

R507/R404A

R22

。对于其他制冷剂,请参

照数据表查不同的制冷量。

 

 
 
 

低温冷风机

(BOHN BHDF

系列)其设计的饱

和吸气温度为

-24°C

,温差为

6K

,适用于室温

-6°C

-32°C

商用冷库(特殊饱和吸气温度

允许的最大和最小温差请参照技术资料)。该
蒸发器推荐使用的制冷剂有

R507/R404A

R22

。对于其他制冷剂,请参照数据表查的不

同的制冷量。更低的库温必须重新设计。

 

These standard evaporators cannot use   Ammonia 
(NH

3

) as refrigerant.         

 
For special design requirements (non standard 
conditions and/or refrigerants such as Glycol, 
Hydrocarbons, etc), please inquire with your local 
representatives and/or Heatcraft Wuxi local branches, 
or call our national telephone number 0510-85282020 
for your nearest available information resources          

这些标准的蒸发器不能用氨

(NH

3

)

作为冷媒。

 

 
 

对于非标设计(非标准工况和

/

或乙二醇、碳

氢化合物等作为冷媒)请咨询西克当地代表和

/

或西克无锡,或者拨

0510-85282020

为您

提供最新的信息。

 

The air pattern shall cover the entire room or 

effective area. 

Do 

NOT

 locate evaporators over doors. 

Locate aisles, racks, etc so as not to hinder the 

discharge or return airflow of the evaporator. 

Locate relative to compressors for minimum pipe 

runs. 

Locate condensate drains for minimum pipe runs. 

气流组织应覆盖整个房间或者有效面积。

 

 

禁止将蒸发器安装在门的上面。

 

过道和货架的布置不能阻碍蒸发器的送风和
回风的流道。

 

蒸发器到压缩机的管道距离尽量短。

 

 

排水管的走管距离尽量短。

 

Содержание BOHN

Страница 1: ...nd Clearance pg 3 Installation Instructions pg 4 a Lifting of Unit pg 4 b Unpacking of Unit pg 4 c Mounting the Unit pg 4 d Condensate Drain Line pg 5 e Refrigerant Distributor and Nozzle pg 5 f TX Va...

Страница 2: ...Defrost Guidelines pg 7 a Defrost Termination Requirements pg 7 b Control Setting Guidelines pg 8 Routine Maintenance of Unit pg 8 General Decommissioning Guide pg 9 Material Safety Data Sheets M S D...

Страница 3: ...l if it is inhaled and or makes contact with exposed skin Refrigerants used in this equipment are controlled substances and must be used and recovered responsibly It is against the law to deliberately...

Страница 4: ...refrigerants For other refrigerants please refer to sales data sheet for capacity variations Low temperature range evaporators Kirby KHDF series are designed at 24 C SST and 6 KTD to suit room temper...

Страница 5: ...1 C is preferred placement C D S2 S1 S2 S2 S1 S2 D is an alternative for the same reason as B D B Where one side of wall mounting will not accommodate all required units or air throw distance must be...

Страница 6: ...ly with HACCP and or relevant regulations for food safety the area above the evaporator must be sealed or exposed in such a way to facilitate hand cleaning without the use of tools So depending on the...

Страница 7: ...igerated room HACCP PVC 1 300mm U U To obtain the best performance of the evaporator the distributor body shall be mounted vertically to ensure refrigerant liquid being distributed evenly to all the c...

Страница 8: ...e shall be taken during installation of the piping to prevent entrance of foreign matter or moisture by minimising the time that the piping is uncapped The interconnecting refrigeration pipe size is n...

Страница 9: ...eets for all the information regarding voltage and current for fan motors and element heaters During field wiring fan motors shall be wired up in star connection After electrical installation units sh...

Страница 10: ...rier will ensure all refrigerant supplied to the refrigeration system is clean and dry The sight glass is a useful device to ensure sufficient refrigerant is supplied to the refrigeration system Refri...

Страница 11: ...avy Load represents the nominal working period of each day 3 X 12 20 Defrost time for average loads should be approx 20 25 minutes including drainage Time will vary with varying degrees of ice build u...

Страница 12: ...iven as a guide During the commissioning this data should be used as a reference initially It is then necessary to fine tune the control settings to achieve the satisfactory defrost results The above...

Страница 13: ...re designed to have low service maintenance requirements Based on normal operation conditions and working environment a service maintenance schedule shall be established after the successful completio...

Страница 14: ...rost completely Look for abnormal accumulation of ice patterns and adjust the defrost cycles accordingly Check the superheat and adjust TX valve accordingly All power must be disconnected before clean...

Страница 15: ...in a potential personal injury hazard Cut and solder seal the refrigeration liquid line and suction line pipe connections Remove the evaporator from its mounting place Adequate support must be provid...

Страница 16: ...to providing safe products and protecting the environment by complying with all applicable national laws and regulations governing environmental protection New and used refrigerants cannot be vented...

Страница 17: ...ED ALLOW 1000 MM MIN FOR AIRFLOW REMOVABLE OPENING ACCESS DOOR AIRFLOW LABEL CEILING MOUNTED ALLOW 600 MM MIN FOR AIRFLOW FOOT MOUNTED ALLOW 1000 MM MIN FOR AIRFLOW ALLOW 520 MM MIN FOR ACCESS PANEL O...

Страница 18: ...2 IF PRESENT 3 Ph FAN MOTOR 3 IF PRESENT FUSE OR CIRCUIT BREAKER 415 V 3 Ph 50 Hz ISOLATION SWITCH BLACK BROWN BLUE G Y W2 U1 U2 V1 V2 W1 W2 U1 U2 V1 V2 W1 3 Ph FAN MOTOR 1 3 Ph FAN MOTOR 2 IF PRESEN...

Страница 19: ...tion by customer L1 COIL HEATER 1 WAGO TERMINALS 1 N BLACK COIL HEATER 2 2 BLACK COIL HEATER 3 3 BLACK TRAY HEATER BLACK 4 L2 L3 COIL HEATER 4 BLACK 5 6 7 BLACK BLACK BLACK BLACK BLACK IF PRESENT 8 E...

Страница 20: ...20070206 20 of 20...

Отзывы: