B. Clearances to Combustibles
When selecting a location for the appliance it is important to
consider the required clearances to walls. See Figure 3.3.
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.3 Appliance Locations
J
C
A
K
H
B
F
D
I
I
F
A
E
G
L
Refer to Section 10.B for mantel and wall
projection information.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
Models
A
B
C
D
E
Min.
F
G
H
I
J
K
L
350X-AU
in.
39-1/2
34
55-7/8
See Section
10.B for
Alcove
Installation
1/2
44
62-1/4
16-1/4
48-1/2
68-3/4
13-1/2
7-1/2
mm
1003
864
1419
13
1118
1581
413
1232
1746
343
191
550X-AU
in.
42
37
59-1/2
1/2
44
62-1/4
16-1/4
48-1/2
68-3/4
15-1/16
7-1/2
mm
1067
940
1511
13
1118
1581
413
1232
1746
383
191
NOTICE:
Additional clearance are required for Heat-Zone
®
-240V
installations. Provisions must be made in advance to ensure fit within the
framing.