background image

Table of Contents:

Page

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Principal of Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Operation & Set Up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Storage & Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Parts Breakdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Wiring Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Installation and Maintenance Manual

Model P1800

Construction Heater

342 N. Co. Rd. 400 East • Valparaiso, IN 46383

219-464-8818 • 888-432-8924 • Fax 800-255-7985

www.heatwagon.com

WARRANTY

All new Heat Wagon and Sure Flame heaters and fans are guaranteed against defective materials and
workmanship for one (1) year from invoice date.

Warranty repairs may be made only by an authorized, trained and certified Heat Wagon dealer.  Warranty
repairs by other entities will not be considered.  Warranty claims must include model number and serial
number.

LIMITATIONS

Warrant claims for service parts (wear parts) such as spark plugs, igniters, flame rods will not be allowed.
Diagnostic parts such as voltage meters and pressure gauges are not warrantable.

Evidence of improper fuel usage, fuel pressures outside of manufacturer’s specification, poor fuel quality,
and improper electric power, misapplication or evidence of abuse may be cause for rejection of warranty
claims.

Travel time, mileage and shipping charges will not be allowed.  Minor adjustments of heaters are dealers’
responsibility.  Defective parts must be tagged and held for possible return to the factory for 60 days from
date of repair.  The factory will provide a return goods authorization, (RGA) for defective parts to be
returned.

No warranty will be allowed for parts not purchased from Heat Wagon.

Содержание p1800

Страница 1: ... future reference 342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com Revision 7 29 02 P1800 For your safety Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored Construction Heater ...

Страница 2: ...r our heaters CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these FOR YOUR SAFETY DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS HAVING FLAMMABLE VAPORS ARE STORED OR USED CONSTRUCTION HEATER GENER...

Страница 3: ... include model number and serial number LIMITATIONS Warrant claims for service parts wear parts such as spark plugs igniters flame rods will not be allowed Diagnostic parts such as voltage meters and pressure gauges are not warrantable Evidence of improper fuel usage fuel pressures outside of manufacturer s specification poor fuel quality and improper electric power misapplication or evidence of a...

Страница 4: ...590 CFM 1 000 Cu m hr Electrical Rating 240V 60Hz Single Phase Single Phase Model Amp draw 75 Amps or 50 Amps Electrical Rating 240V 60Hz Three Phase Three Phase Model Amp draw 25 Amps or 17 Amps Phase Ambient Thermostat Temp Range 32 to 100 F 0 40 C Dimensions 30 L x 14 W x 20 H Weight 62 lbs 4 Principal of Operation ...

Страница 5: ...ck your heater to make sure whether it is wired for one or three phase use 3 Set the remote thermostat to a temperature above the ambient room temperature by turning the knob NOTE The heater will start only if the thermostat calls for heat meaning that it is set to higher than prevailing ambient temperature 4 Turn the main switch into position 1 for ventilation 2 for partial output 1 2 kw or 3 for...

Страница 6: ...ot Severe bodily injury or electric shock may occur Only qualified persons are allowed to open heater for service 1 Keep heater clean Use pressurized air to blow fan blades clean NOTE Use moderate pressure to avoid damage to fan blades 2 Inspect heater before and after each use 3 The bearings of the fan motor are permanently lubricated and sealed No additional lubrication is needed ...

Страница 7: ...P 180018 THERMOSTAT KNOB 19 HWP 180019 REAR GRILL 20 HWP 180020 WIRE BUSHING 21 HWP 180021 MAIN SWITCH ASSY Item Part No Description 22 HWP 180022 CONTRACTOR 23 HWP 180023 TERMINAL BLOCK 23A HWP 180023A TERMINAL BLOCK PACK 24 HWP 180024 OVERHEAT LIMIT SWITCH 25 HWP 180025 UNIT COOLDOWN SWITCH 26 HWP 180026 HEATING ELEMENT See wiring diagram for electric parts Parts Not Shown HWP 180027 CIRCUIT BRE...

Страница 8: ...MOSTAT TC UNIT COOLDOWN THERMOSTAT R1 R9 HEATING ELEMENTS WIRING DIAGRAM HEAT WAGON P1800 SINGLE PHASE WIRING DIAGRAM HEAT WAGON P1800 THREE PHASE C1 C2 CONTACTORS COILS M FAN MOTOR S1 MAIN SWITCH TA AMBIENT THERMOSTAT TO OVERHEAT LIMIT SWITCH TE OUTLET AIR THERMOSTAT TC UNIT COOLDOWN THERMOSTAT R1 R9 HEATING ELEMENTS ...