IMPORTANT INFORMATION! READ FIRST

The heater is designed for use as a construction heater under ANSI Z83.7a-1993. Heater is not
intended for use in pest remediation.  The primary purpose of construction heaters is to provide
temporary heating of buildings under construction, alteration, or repair and to provide emer-
gency heat. Properly used, the heater provides safe, economical heating. Products of combustion
are vented into the area being heated.

The heater 

IS NOT

designed as an Unvented Gas Fired Room Heater under ANSI-Z21.11.2 and

SHOULD NOT

be used in the home.

ANSI A119.2(NFPA 501C)-1987 Recreational Vehicle Standard prohibits the installation or stor-
age of LP-gas containers even temporarily inside any recreational vehicle. The standard also pro-
hibits the use of Unvented Heaters in such vehicles.

NFPA-58 1989 STANDARD FOR THE STORAGE AND 

HANDLING OF LIQUEFIED PETROLEUM GASES AND THE NATURAL GAS AND PROPANE

INSTALLATION CODE, CSA B149.1

Use of the heater must be in accordance with this Standard and in compliance with all governing
state and local codes. Storage and handling of propane gas and propane cylinders must be in
accordance with standard for the storage and handling of liquified petroleum gases, ANSI/NFPA
58 and CSA B149.1, natural gas and propane installation code and all local governing codes.

We cannot anticipate every use which may be made for our heaters. 

CHECK WITH YOUR

LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS.

Other standards govern the use of fuel gases and heat producing products in specific applica-
tions. Your local authority can advise you about these.

FOR YOUR SAFETY

DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER 

LIQUIDS HAVING FLAMMABLE VAPORS ARE STORED OR USED.

CONSTRUCTION HEATER GENERAL HAZARD WARNING:

Failure to comply with the precautions and instructions provided with this

heater, can result in death, serious bodily injury and property loss or damage

from hazards of fire, explosion, burn, asphyxiation, carbon monoxide 

poisoning, and/or electrical shock.

Only persons who can understand and follow the instructions should use or

service this heater.

If you need assistance or heater information such as an instruction manual, labels,
etc., contact your local Heat Wagon dealer or the manufacturer.

W

A

R

N

I

N

G

Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as build-
ing materials, paper or cardboard, a safe distance away from the heater as recom-
mended by the instructions. Never use the heater in spaces which do or may contain
volatile or airborne combustibles, or products such as gasoline, solvents, paint thin-
ner, dust particles or unknown chemicals.

Not for home or recreational vehicle use!

Never Use The Heater In Spaces Which Are Not Sufficiently Sized

Or Ventilated For The Heater Being Utilized.

Содержание HRF115

Страница 1: ...e retain this manual for future reference 342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com Revision 2 21 For your safety Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored SN 96004001 and beyond ...

Страница 2: ...overning codes We cannot anticipate every use which may be made for our heaters CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS Other standards govern the use of fuel gases and heat producing products in specific applica tions Your local authority can advise you about these FOR YOUR SAFETY DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS H...

Страница 3: ...nsidered Warranty claims must include model number and serial number LIMITATIONS Warrant claims for service parts wear parts such as spark plugs igniters flame rods will not be allowed Diagnostic parts such as voltage meters and pressure gauges are not warrantable Evidence of improper fuel usage fuel pressures outside of manufacturer s specification poor fuel quality and improper electric power mi...

Страница 4: ...4 A B A without thermostat B with thermostat ...

Страница 5: ...5 0 60 x 80 S 0 125 Fig 1 ...

Страница 6: ...6 Mains must be fitted with a breaker switch such as for example a thermostat is connected to the generator ...

Страница 7: ...7 fuel ...

Страница 8: ...Overheat thermostat Replace capacitor capacitor If heater is still not working properly please call Heat Wagon Tech Service Confirm that air flap 37 diffuser ring 38 and air adjustment disc 39 are clean and adjusted to provide an open line of sight for flame sensor ...

Страница 9: ... FOR 7 RED BLINKS CAUSE MAY BE Out of fuel Filter or nozzle blocked Broken fuel line intake sucking air Bad photocell Overheat limit switch tripped Non volatile lockout manual reset in order to reset the system the reset button must be pressed less than 5 seconds Volatile lockout turn selector switch to OFF position hold reset button for a least one minute red light should go out let control board...

Страница 10: ...10 ...

Страница 11: ...IE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE T20339 14 7 11 8 18 14 uF BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE BIE 60 x 80º S E50327 40 E50335 G11089 Bumper G11089 Phototransistor ...