PROPER SET UP
(NOTE: The 2730C must be specifically set up for the type of available fuel PRIOR to
installation)
Model 2730C with built-in vaporizer. The heater will use 22 gallon of L.P. per hour. Use at least one
500 gal. Liquid withdrawal tank. This will insure 20
hours of continuous operation.
When running unit on Liquid Propane, the heater
must be set up outside of the building, forcing the
heat through a building opening.
•Hose size for Liquid Propane
–up to 25’ 3/8” ID
–up to 50’ 1/2” ID
Keep hose length as short as possible.
Model 2730C, if setup for Vapor Propane withdraws 2,000,000 BTU’s per hour.
Proper Tank sizing is essential. A propane tank can only make X amount of Vapor per hour. With
drawing the vapor at a faster rate will frost the tank and eventually the burner will run out of fuel.
Hose sizing Vapor Propane
•Up to 100’, use 3/4” or larger hose
For Natural Gas applications you must know the available line pressure and pipe inside diameter.
Call the factory for the proper size of orifice, gas manifold and hose.
Vapor Propane and Natural Gas Units can be used inside the building or outside.
•Wire heater directly into fused disconnect
Power Supply line sizing:
2730 - 240V - under 75’
10 ga.
3 conductor
75 ft to 100 ft
8 ga.
3 conductor
2730 - 480V - under 75’
14 ga.
4 conductor
75 ft to 150 ft
12 ga.
4 conductor
Position heater properly before use.
Install heater in a horizontal position. Clearances required for combustibles and containers.
Front Outlet
12 ft
Intake
2 ft
Sides
2 ft
Top
4 ft
For your safety do not use this heater in a space where gasoline or other liquids, having flammable
vapors, are stored or used.
LARGE PROPANE STORAGE TANK VAPORIZATION RATE
TANK SIZE:
MAXIMUM WITHDRAWAL RATE (BTUH):
40”
30”
20”
0”
500 gallon
480,000
420,000
360,000
300,000
1000 gallon
850,000
740,000
640,000
530,000