IMPORTANT INFORMATION! READ FIRST

The heater is designed for use as a construction heater under ANSI Z83.7a-1993. Heater is not
intended for use in pest remediation.  The primary purpose of construction heaters is to provide
temporary heating of buildings under construction, alteration, or repair and to provide emer-
gency heat. Properly used, the heater provides safe, economical heating. Products of combustion
are vented into the area being heated.

The heater 

IS NOT

designed as an Unvented Gas Fired Room Heater under ANSI-Z21.11.2 and

SHOULD NOT

be used in the home.

ANSI A119.2(NFPA 501C)-1987 Recreational Vehicle Standard prohibits the installation or stor-
age of LP-gas containers even temporarily inside any recreational vehicle. The standard also pro-
hibits the use of Unvented Heaters in such vehicles.

NFPA-58 1989 STANDARD FOR THE STORAGE AND 

HANDLING OF LIQUEFIED PETROLEUM GASES AND THE NATURAL GAS AND PROPANE

INSTALLATION CODE, CSA B149.1

Use of the heater must be in accordance with this Standard and in compliance with all governing
state and local codes. Storage and handling of propane gas and propane cylinders must be in
accordance with standard for the storage and handling of liquified petroleum gases, ANSI/NFPA
58 and CSA B149.1, natural gas and propane installation code and all local governing codes.

We cannot anticipate every use which may be made for our heaters. 

CHECK WITH YOUR

LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS.

Other standards govern the use of fuel gases and heat producing products in specific applica-
tions. Your local authority can advise you about these.

FOR YOUR SAFETY

DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER 

LIQUIDS HAVING FLAMMABLE VAPORS ARE STORED OR USED.

CONSTRUCTION HEATER GENERAL HAZARD WARNING:

Failure to comply with the precautions and instructions provided with this

heater, can result in death, serious bodily injury and property loss or damage

from hazards of fire, explosion, burn, asphyxiation, carbon monoxide 

poisoning, and/or electrical shock.

Only persons who can understand and follow the instructions should use or

service this heater.

If you need assistance or heater information such as an instruction manual, labels,
etc., contact your local Heat Wagon dealer or the manufacturer.

W

A

R

N

I

N

G

Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as build-
ing materials, paper or cardboard, a safe distance away from the heater as recom-
mended by the instructions. Never use the heater in spaces which do or may contain
volatile or airborne combustibles, or products such as gasoline, solvents, paint thin-
ner, dust particles or unknown chemicals.

Not for home or recreational vehicle use!

Never Use The Heater In Spaces Which Are Not Sufficiently Sized

Or Ventilated For The Heater Being Utilized.

Содержание 1800B(L)

Страница 1: ...in this manual for future reference 342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com Revision 7 15 For your safety Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored NRTL ANSI Z83 7 CONST HTR ...

Страница 2: ...overning codes We cannot anticipate every use which may be made for our heaters CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS Other standards govern the use of fuel gases and heat producing products in specific applica tions Your local authority can advise you about these FOR YOUR SAFETY DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS H...

Страница 3: ... by other entities will not be considered Warranty claims must include model number and serial number LIMITATIONS Warrant claims for service parts wear parts such as spark plugs igniters flame rods will not be allowed Diagnostic parts such as voltage meters and pressure gauges are not warrantable Evidence of improper fuel usage fuel pressures outside of manufacturer s specification poor fuel quali...

Страница 4: ...DURABLE CONSTRUCTION The Model 1800B L uses a heavy gauge steel housing and a stainless steel burner for long life and consistent performance NOTE In order to maintain the highly efficient combustion of the heater the combustion cham ber must remain as manufactured Any change or distortion could alter the fuel air mixture and create excessive products of combustion SPECIFICATIONS Model No 1800B 18...

Страница 5: ...put into operation The replacement hose assembly shall be that specified by the manufacturer 4 When connecting the heater to a natural gas or propane supply line ensure that the pressure at the heater inlet is within the specified range Excessive pressure over 14 W C will damage the controls and void the warranty 5 Connect the hose assembly to the heater gas inlet elbow The 1800B elbow has a 3 4 f...

Страница 6: ...r manifold to the Propane position When using Natural Gas turn the selector valve to the Natural Gas position This unit can be set up indoors or out 6 NATURAL GAS QUICK REFERENCE HOSE CHART Hose BTU Length 750 000 in Feet 1PSI 1PSI 2PSI 5PSI 10 1 1 2 1 3 4 3 4 25 1 1 2 1 3 4 3 4 35 1 1 2 1 3 4 3 4 50 2 1 1 3 4 75 2 1 1 4 1 3 4 100 2 1 1 4 1 3 4 125 2 1 1 4 1 1 4 3 4 150 2 1 1 4 1 1 4 3 4 175 2 1 1...

Страница 7: ...e above National Standard COMMON INSTALLATION AND OPERATIONAL PROBLEMS 1 LOW VOLTAGE AT THE HEATER This is one of the most common problems and is usually the result of the supply cord having too small a wire gauge for its length or low voltage at the power source Low voltage results in the motor overheating burnt relay contacts or a relay that will not make contact Check voltmeter before start up ...

Страница 8: ...owly open shut off valve at gas meter or propane tank Check for leaks 5 Push up the ON switch 6 Set thermostat for desired room temperature 7 To stop turn thermostat down or push down the stop switch Burner will turn off after 5 seconds fan will turn off 8 Close manual shut off valve on heater NOTE FAN ONLY switch must be in the Off position for Heat Mode NOTE If the heater will be shut down over ...

Страница 9: ... power from IND terminal to coil of the motor relay 8 MOTOR RELAY With its coil energized it closes its contacts sending power to the fan motor 9 FAN MOTOR Turns the fan blade causing the air flow switch to close 10 AIR FLOW SWITCH Received its power from the thermostat and sends the power to the indicator light and the DSI control PSW terminal 11 DSI CONTROL Sends power from IND terminal to coil ...

Страница 10: ...ifold gauge if gas is present clean the port holes in burner Flame occurs but burner locks out after a few seconds Check the flame rod if the porcelain is cracked or the electrode is rubbery replace it If the 1st step checks out replace the DSI control Flame occurs but small Check proper pressure at manifold gauge If yes A Clean port holes in burner B Check proper position of Gas selector valve Fo...

Страница 11: ...ain the reliable performance required it is necessary to do a certain amount of regular maintenance 1 CHECK POWER CORD A Insulation not frayed or cracked B Ground peg is there on male end C Polarity is correct Black wire on fuse white wire on neutral block 2 CHECK ALL WIRING FOR PROPER CONNECTIONS 3 CHECK MOTOR RELAY A If it buzzes clean contacts or replace B Check for voltage drop through contact...

Страница 12: ... SFP 4490 2nd Stage Regulator Valve 12 MODEL 1800B VAPOR PIPE TRAIN MODEL 1800BL LIQUID PIPE TRAIN Item Part Description 6 HWP HR1053 HIGH PRESSURE REGULATOR 7 HWP HV1042B HOSE 8 HWP HV1039 SAFETY RELIEF VALVE 9 HWP HV1137 LIQUID PROPANE SOLENOID VALVE 10 HWP HV1054 LIQUID PRESSURE GAUGE 11 HWP HV1129 LIQUID STRAINER 12 HWP HV1123 MANUAL SHUT OFF VALVE 13 HWP HV1140 COIL ...

Страница 13: ...B1800B BODY 9 HWP HB1171 BURNER 10 HWP HW1164 WHEEL 8 x 1 75 x 1 2 HUB 11 HWP HW1164B AXLE FOR 1800 Accessories 0 30 PSI PRESSURE GAUGE HWP HV1027 REGULATOR HWP HR1053 HIGH TEMPERATURE DUCT 950H ACC WD2425HT 1800B ACC WD2025HT GAS HOSE ACC 7525 3 4 x 25 ACC 7550 3 4 x 50 ACC 1025 1 x 25 ACC 1050 1 x 50 CSA certified for NG and Propane Female Swivel Union Included P O L FITTING TO CONNECT TO PROPAN...

Страница 14: ... Block 9 HWP HC1115 Fuse 20 amp 10 HWP 44130 Light 11 HWP HC1011 Fan Only Switch 12 HWP HC1019B 3amp Breaker 13 HWP HC1150 OFF Switch 14 HWP HC1149 ON Switch 15 HWP HC1123 Terminal Block D 16 HWP HC1120 Thermostat w o cord not shown 17 HWP HC1020 Power cord not shown 18 HWP HC1005 Ignition wire assembly not shown 19 HWP HC1006 Flame rod wire assembly not shown 20 SFP 2142 Spark plug not shown 21 S...

Страница 15: ...15 ...

Страница 16: ...16 1800B CONTROL BOX WIRING No Neutral Shown ...