HTP BAY & HTP STANDARD
PELLET STOVE
OWNER’S MANUAL
Installation, Operating and
Maintenance Instructions for
Pellet Stoves
Страница 1: ...HTP BAY HTP STANDARD PELLET STOVE OWNER S MANUAL Installation Operating and Maintenance Instructions for Pellet Stoves...
Страница 2: ...ur products We assure you that with proper management your HEAT TECH stove will provide you with many years of comfort and enjoyment Please read this owner s manual and follow the guidelines thoroughl...
Страница 3: ...PERATION WARNINGS AND PRECAUTIONS 11 BASIC OPERATION 12 SHUT DOWN PROCEDURES 13 MAINTENANCE 14 ASH REMOVAL 14 CLEANING AND SERVICING 14 TROUBLE SHOOTING 16 Stove shuts off and the 2 light flashes 16 S...
Страница 4: ...led on a hearth of masonry or metal fireplace It is also approved as a mobile home heater and is designed for connection with an outside air source This stove will NOT operate using a natural draft or...
Страница 5: ...tove dealer may have already done this NOTE Minor smoking and steaming is normal during the curing process Use only listed and approved stovepipe designed for use with pellet stove Follow pipe manufac...
Страница 6: ...ES Your Heat Tech freestanding stove has 3 clearances to combustibles on back and sides The hearth pad must extend out a minimum of 3 from the stove on each side and a minimum of 6 in front of the doo...
Страница 7: ...rk center point on the ceiling Cut asquare hole in ceiling to accommodate fire stop support assembly 9 5 8 square hole for 3 or 10 5 8 square hole for 4 Connect chimney section from stove upwards When...
Страница 8: ...tom WHEN VENT PIPE EXTENDS TO CHIMNEY TOP o Refer to Figure 13 o You will need a pipe length equal to the chimney height from hearth plus 6 If outside combustion air is to be used youwill need a pipe...
Страница 9: ...de to wind hood or turned down at 90 degrees to prevent back draft Outside air can also be channeled through the floor under the stove and through the pedestal and into the firebox SOURCES OF OUTSIDE...
Страница 10: ...to the terminal block on thelower left side of the back of the control board See FigureXXX Insert the wires in the terminal side and tighten the twoscrews MODES To switch between any of the three mode...
Страница 11: ...off The fans will continue to run until the stovecools o When the home cools below the thermostat setting thestove will automatically restart and run at the last feed ratesetting NOTE When in high lo...
Страница 12: ...l Premium fuel provides quality heat for the investment and makes for trouble free operation Ask your dealer which fuels are the best for your stove DO NOT BURN WALNUT BY PRODUCT PELLET OR ANY PELLET...
Страница 13: ...s operation Do not add more fuel to the burn pot than the automatic fuel system provides as this could cause an over firing condition Do not service this appliance without disconnecting power cord If...
Страница 14: ...ES Turning the Heat Tech pellet stove off is simply a matter of turning the control panel switch to OFF The blowers will continue to operate until the internal firebox temperatures have fallen to a pr...
Страница 15: ...d container until all cinders have thoroughly cooled CLEANING AND SERVICING If you choose to clean and service your stove on your own you should follow these steps With the front door of your stove op...
Страница 16: ...light to make sure bottom is completely vacuumed out At the end of each burn season the stove should be completely and cleaned and serviced This is done by removing the back of thestove and oiling the...
Страница 17: ...ns in the Installation section Bad wire connections to the airflow switch Check that the connections of the grey wires to the airflow switch are intact and properly wired Bad wire connections at the M...
Страница 18: ...e of wire Plug the stove back in If the stove works the Proof of Fire thermodisk is bad and must be replaced WARNING DO NOT LEAVE THE PROOF OF FIRE THERMODISK BYPASSED If it remains bypassed the blowe...
Страница 19: ...g to the convection blower If there is power being sent to the blower when it is shut off then the control board is fine If there is NOT power being sent to the blower when it shuts off during operati...
Страница 20: ...runs constantly the board is bad Combustion blower is not spinning fast enough Test the RPM on the blower after the blades have been cleaned The RPM should be approximately 3000 RPM Bad pellets applie...
Страница 21: ...spike or voltage drop could cause the high limit switch to trip Check to see if a surge protector is being used on the stove If not recommend one to the consumer High limit switch is malfunctioning If...
Страница 22: ...DIAGRAMS Page 21...
Страница 23: ...Page 22...
Страница 24: ...official warranty claim form and must reflect the specific nature of the problem The limited warranty covers defects in materials and workmanship as long as the product has been installed according t...