7
If bulbs refuse to light, check the 2 conductor plug for connection. To examine the plug the front glass
must be removed. Locate the 6 mounting screws, 3 on each side, remove all 6 and lift off front glass. Next
remove the 3 top screws holding the flame screen; the plug is located on the right hand side. The plug will
have a yellow and a white wire on one side and a black and white wire leading to the sockets. Check for
good connection. Refer to Figure 7.
Figure 7, lamp plug location
If the plug connection is good, check for voltage between terminals LAMP and AC-N1 on the main control
board, (60vac to 120vac depending flame brightness set point). Refer to Figure 3 and Figure 4, for board
and terminal locations, if there isn’t any voltage present, the main control board is defective, replace with
a new board.
Front glass mounting screws, quantity 6.
Flame screen mounting screws, quantity 3.
Repair connection,
plug in Lamps.