11
Operation
Operation
Before igniting the appliance, perform the “Leakage Testing” in a well ventilated area
(outdoors). On first use and after every LPG cylinder change, the appliance gas circuit
must be purged of air before igniting! To do this, turn the control knob counter-clockwise
to the ignition position and push and hold for 1 minute before
attempting ignition .
To turn on the heater
1 . Ensure the LPG cylinder has 4/5 its capacity and contains proper LPG Gas
(refer to Technical Data on page)
.
2 . Turn LPG cylinder valve to the full
ON
position and close the LPG
compartment panel . Ensure the burner control knob is in the
OFF
position (full disk) .
3 . Push the control knob and keep pressing
while turning counter-clockwise to the
corresponding HIGH position (big flame). At
the same time push the ignition button . The
ignition will spark automatically .
4 . When the burner is lit in Maximum position
(big flame), stop pushing the ignition button
(star) and keep the control knob pressed for
10 - 20 seconds. Then release it (the first
ignition usually takes more time, because the
gas circuit is full of air) .
Note
• If the burner does not stay lit, wait 5 minutes and then
repeat steps 3 and 4 .
• Adjust the heat input by turning the knob from the
Maximum position (big flame), to the Minimum position.
• After lighting, turn knob from Minimum to Maximum (big
flame) position and back, to check flame stability.
• In case of accidental flame outage (for wind or other reasons), FSD will shut-off gas
supply automatically (FSD = Flame Safety Device) .
• The burner may be noisy when initially turned on
• To eliminate excessive noise from the burner, turn the control knob to the Minimum
position and back. If you experience any ignition problem consult “Troubleshooting”.