Heat-N-Glo BE-41 Скачать руководство пользователя страница 1

1

- Do not store or  use gasoline or other flam-

mable vapors and liquids in the vicinity of this

or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's

instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas

supplier.

Installers Guide

WARNING:  IMPROPER  INSTALLA-

TION, ADJUSTMENT, ALTERATION,

SERVICE  OR  MAINTENANCE  CAN

CAUSE INJURY OR PROPERTY DAM-

AGE. REFER TO THIS MANUAL. FOR

ASSISTANCE OR ADDITIONAL INFOR-

MATION  CONSULT A  QUALIFIED  IN-

STALLER, SERVICE AGENCY, OR THE

GAS SUPPLIER.

Underwriters

Laboratories Listed

394-900B  9/00

READ THIS MANUAL BEFORE INSTALLING OR

OPERATING THIS APPLIANCE. THIS 

INSTALLERS

GUIDE 

MUST BE LEFT WITH APPLIANCE FOR

FUTURE REFERENCE.

1. This appliance may be installed in an af-

termarket, permanently located, manufac-

tured (mobile) home, where not prohibited

by local codes.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This

appliance is not convertible for use with

other gases, unless a certified kit is used.

Please  contact  your  Heat-N-Glo  dealer  for  any

questions  or  concerns.  For  the  number  of  your

nearest Heat-N-Glo dealer, please call 952-985-6000.

Printed in U.S.A.   Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.

20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATION

IN THESE INSTRUCTIONS IS NOT

FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUS-

ING PROPERTY DAMAGE, PER-

SONAL INJURY, OR DEATH.

This  product  is  covered  by  one  or  more  of  the  following  patents:  (United  States)  4,112,913;  4,408,594;  4,422,426;  4,424,792;  4,520,791;  4,793,322;

4,852,548;  4,875,464;  5,000,162;  5,016,609;  5,076,254  5,191,877;  5,218,953;  5,328,356;  5,429,495;  5,452,708;  5,542,407;  5,613,487;  (Australia)

543790;  586383;  (Canada)  1,123,296;  1,297,746;  2,195,264;  (Mexico)  97-0457;  (New  Zealand)  200265;  or  other  U.S.  and  foreign  patents  pending.

Model:

BE-41

Содержание BE-41

Страница 1: ...UTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 Thisapplianceisonlyforusewiththetype of gas indica...

Страница 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Страница 3: ...10 Step 3 Installing the Vent System 12 A Vent System Approvals 12 B Installing Vent Components 18 C Vent Termination 21 Step 4 Positioning Leveling and Securing the Fireplace 24 Step 5 The Gas Contr...

Страница 4: ...1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada 1Approvals and Codes High Altitude Installations U L Listed gas fireplaces are...

Страница 5: ...eplace and its components are tested and safe when installed in accordance with this Installers Guide Report to your dealer any parts damaged in shipment particularly the condition of the glass Do not...

Страница 6: ...unit is to be installed The vent system configuration to be used Gas supply piping Electrical wiring Framing and finishing details Whether optional accessories devices such as a fan wall switch or re...

Страница 7: ...the face of the fireplace is one inch 25 mm The back of the fireplace may be recessed 21 1 2 inches 546 mm into combustible construction Minimum Clearances from the Vent Pipe to Combustible Materials...

Страница 8: ...below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING 1 2 CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE 0...

Страница 9: ...3 8 INCHES 34 93mm AT EACH JOINT DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35...

Страница 10: ...nting configuration used Terminations Kits Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical...

Страница 11: ...Up Vertical Venting NOTE On vertical venting configurations where the vertical component is over 10 feet you may want to install the vertical baffle VERT BAF see Figure 7 STRAIGHT UP VERTICAL VENTING...

Страница 12: ...e 90 Elbow VENTING WITH ONE 1 90 ELBOW VENTING WITH ONE 1 90 ELBOW V FT H FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H 40 MAX 12 4MM H 20 MAX...

Страница 13: ...914 mm 6 MAX 1 86 m 15 MAX 4 65m 4 MIN 1 22 m 8 MAX 2 48 m 20 MAX 6 2m V H H1 40 MAX 12 4 m H 8 MAX 2 48 m H H1 20 MAX 6 2m Figure 12 Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H...

Страница 14: ...914mm 6 MAX 1 86m 15 MAX 4 65m 4 MIN 1 22m 8 MAX 2 48m 20 MAX 6 2m V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48 m H H1 H2 20 MAX 6 2 m V H H H1 H2 1 MIN 305mm 2 MAX 610mm 5 MAX 1 52m 2 MIN 610mm 4 MAX 1 22m...

Страница 15: ...m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m NOTE H H1 20 MAX 6 2m V V1 H H1 40 MAX 12 4m V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX...

Страница 16: ...inch 127mm fireplace starting collar Make sure that the fiberglass rope gasket supplied with the fireplace seals between the first 8 5 8 inch 219mm vent component and the outer fireplace wrap Lock th...

Страница 17: ...e supports to the framing members Figure 17 Adding Venting Components For Vertical Runs The vent system must be supported every eight 8 feet 2 4m above the fireplace flue outlet by wall brackets To in...

Страница 18: ...the vent passes To install firestops for vertical runs that pass through ceilings Position a plumb bob directly over the center of the verti cal vent component Mark the ceiling to establish the center...

Страница 19: ...OR SIDING SEE THE FOL LOWING DIAGRAM FOR VENT TERMINATION CLEARANCES ROUND CAP TERMINATION PERFORATION CANNOT BE INSIDE THE WALL 7 1 2 191mm MINIMUM TRAPEZOID CAP TERMINATION 7 1 4 184mm WARNING THET...

Страница 20: ...or that may be opened C 9 U S A 12 Canada clearance to permanently closed window D 18 vertical clearance to ventilated soffit located above the termi nal within a horizontal distance of 2 feet 60 cm f...

Страница 21: ...FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET FROM A VERTICALWALLAND 2 FEET BELOWA HORIZON TAL OVERHANG NOTE This also pertains to vertical vent systems i...

Страница 22: ...position level and secure the fireplace Figure 27 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The type of g...

Страница 23: ...vent cold air infiltration Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching the pipe support the control so that the lines...

Страница 24: ...witch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WA...

Страница 25: ...NSI or CAN CGAtesting standardsdonot require hearth extensions for gas fireplace appliances Figure 33 Sealant Material HIGH TEMPERATURE SIDE SEAL JOINT 300 F 149 C MIN TOP O O 0 0 FINISH WALL MATERIAL...

Страница 26: ...of the tie in the fireplace see Figure 35 WARNING USE WIRE CUT TERS DO NOT ATTEMPT TO CUT THE TIE WITH A KNIFE 3 Grasp the log assembly by the ends Do NOT grasp the log as sembly by the center Remove...

Страница 27: ...rward on the refractory see Figure 37 7 Cut shrink wrap and remove from around the log assembly WARNING REMOVE ALL PACKAGING FROM LOGS 8 Install embers See ember placement instructions for details WAR...

Страница 28: ...e chemicals used in the paint and logs Step 12 Lighting the Fireplace You ve reviewed all safety warnings you ve checked the fireplace for gas leaks you know the vent system is unobstructed and you ve...

Страница 29: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...

Отзывы: