Heat-N-Glo ATS-AUST Скачать руководство пользователя страница 13

12

FIGURE 14

2.0

OPERATING INSTRUCTIONS

The control system for these models is a millivolt type.
It consists of a gas control valve/variable regulator, a
standing pilot assembly, a thermopile, a piezo ignitor,
and an ON/OFF rocker switch. The controls  are lo-
cated in the lower compartment  behind the lower grille.
Access to this compartment is gained  by rotating the
grille up. See Figure 1.

WARNING:

DO NOT CONNECT 240 VAC TO THE

GAS CONTROL VALVE OR CONTROL WIRING SYS-
TEM OF THIS UNIT.

The gas control system is wired so the thermopile, when
heated with the pilot light, will provide approximately 350
to 500 millivolts.  This activates the gas control valve.
See Figure 14 for appliance wiring diagram.

When lit for the first time, the appliance will emit a slight
odor for an hour or two.  This is due to paint and lubri-
cants used in the manufacturing process.  Additionally,
for the first few minutes after each lighting, vapor may
condense and fog the glass and the flames may be blue.
After a few minutes this moisture will disappear and within
15-30 minutes the flames should become yellow.

The heater may produce a noise, caused from metal
expansion and contraction as it heats up and cools down.
This noise is similar to one that a furnace heat duct
may produce and does not affect the operation or lon-
gevity of the heater.

OPERATING CAUTIONS

THIS APPLIANCE MAY EXHIBIT A SLIGHT CAR-
BON DEPOSITION.

DO NOT PLACE ARTICLES ON OR AGAINST
THIS APPLIANCE.

DO NOT USE OR STORE FLAMMABLE MATERI-
ALS NEAR THIS APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF
THIS APPLIANCE WHILE IT IS IN OPERATION.

THE DRESS GUARD IS FITTED TO THIS APPLI-
ANCE TO REDUCE THE RISK OF FIRE OR INJURY
FROM BURNS AND NO PART OF IT SHOULD BE
PERMANENTLY REMOVED. FOR PROTECTION
OF YOUNG CHILDREN OR THE INFIRM, A SEC-
ONDARY GUARD IS REQUIRED.

THE GLASS DOOR ASSEMBLY MUST BE IN
PLACE AND SEALED AND THE FIXED MESH
DRESS GUARD MUST BE IN PLACE ON THE
HEATER BEFORE THE UNIT CAN BE PLACED
INTO SAFE OPERATION.

DO NOT USE THIS APPLIANCE IF ANY PART
HAS BEEN UNDER WATER.  IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE UNIT AND TO REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDERWATER.

Содержание ATS-AUST

Страница 1: ...MN 55378 USA 612 890 8367 INSTALLATION AND OPERATION INSTRUCTIONS This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 520 791 4 793...

Страница 2: ...be observed This appliance and it s components are tested and safe when installed in accor dance with this Installation Manual Report to your dealer any parts damaged in shipment specifically check g...

Страница 3: ...7 Log Installation 11 1 8 Installer Testing 11 2 0 Operating Instructions 12 2 1 Safety and Lighting Information 13 2 2 Safety Information 13 2 3 Lighting Instructions 14 2 4 Fan Operation 15 3 0 Ser...

Страница 4: ...3 FIGURE 1...

Страница 5: ...CE OPENING WIDTH 32 1 8 816mm DEPTH 13 1 2 343mm HEIGHT 20 1 2 521mm NOTE If exhaust collar on insert and fireplace damper do not line up add 4 inches 102mm to minimum fireplace opening height to acco...

Страница 6: ...F THE UNITANDTHE CENTER COLLAR OF THE TERMINATION CAP THE INLETAIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAROFTHEUNITAND ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP MODEL FLUE TE...

Страница 7: ...6 FIGURE 4 FIGURE 5...

Страница 8: ...r being siphoned from the outside of the building and all exhaust gases expelled to the outside of the build ing This model is designed to be installed in a ma sonry fireplace or factory built firepla...

Страница 9: ...hold the collar bracket from sliding backwards Attach the pipe to cap adaptor to the termination cap and to the top of the flexible flue pipe and set the cap in place at the top of the chimney See Fi...

Страница 10: ...1 4 FAN Model ATS AUST has a factory installed Fan Junction Box variable speed Rheostat Control Switch and Tem perature Sensor Switch for the fan The fan tempera ture sensor switch and junction box ar...

Страница 11: ...ests against the log bracket at the left side of the firebox Drive a wood screw through this bracket and into log number 2 Step 3 Place Log Number 3 with it s flat side down between the rear log and t...

Страница 12: ...leting the gas line connection a small amount of air will be in the lines When first lighting the pilot light it will take a few minutes for the lines to purge themselves of this air Once the purging...

Страница 13: ...w minutes this moisture will disappear and within 15 30 minutes the flames should become yellow The heater may produce a noise caused from metal expansion and contraction as it heats up and cools down...

Страница 14: ...t try to repair it Call a quali fied service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qua...

Страница 15: ...ion turn the control knob counter clockwise to the Pilot position 7 Tolightthepilotdepressthecontrolknobandthen depress the red piezo button until it makes a clickingsound Itmaybenecessarytorepeatthis...

Страница 16: ...NG Frequency of heater servic ing will depend upon use and type of installation B IMPORTANT TURN OFF GAS BEFORE SERVIC ING APPLIANCE IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM SERVI...

Страница 17: ...up and remove the log set log grate and refractory Unscrew the brackets at both ends of the burner and slide the burner to the right away from the burner orifice 2 Pilot Assembly Ignition System Remov...

Страница 18: ...cted re place ignitor 1 Using a match light pilot If pi lot lights turn off pilot and trig ger the red button again If pilot lights an improper gas air mix ture caused the bad lighting and a longer pu...

Страница 19: ...for proper connections Place jumper wires across terminals at switch if burner comes on re place defective switch If OK place jumper wires across switchwiresatgasvalve ifburner comes on wires are fau...

Страница 20: ...read greater than 100 m v If the reading is okay and the burner does not come on replace the gas valve 1 Checkburner orificeforstoppage and remove 1 Follow corrective action in A 1 above check switch...

Страница 21: ...rtain glass assembly is in stalled correctly and tighten cor ner 1 The horizontal flue cap should slope down only enough to pre vent any water from entering the unit The maximum downward slope is 1 4...

Страница 22: ...isted in this manual may be ordered from an authorized dealer PART PART DESCRIPTION PART NUMBER Robertshaw Valve LP SRV60 522 Robertshaw Valve NG SRV60 523 Burner Orifice LP SRV57 801 Burner Orifice N...

Страница 23: ...ONT PART PART DESCRIPTION PART NUMBER Glass Assembly SRV438 650A Glass Fastener Assembly SRV79 001A Piezo Ignitor SRV60 513 Thermopile SRV60 512 On Off Rotary Switch SRV436 525A Pilot Assembly LP SRV6...

Страница 24: ...3 4 0 REPLACEMENT PARTS ATS AUST CONT PART PART DESCRIPTION PART NUMBER Refractory Base SRV438 700 Log Set Assembly SRV428 700A Dress Guard DF ATS AU Surround With Trim ATS AU 4028 Surround ATS AU 362...

Страница 25: ...aleprice defectiveelectricalormanualcomponents optional componentsoraccessories andglasspanels notincludingglasspanelsbrokenduringmisuseorcareless handling HEAT N GLOshallnotberesponsibleforanylabor t...

Отзывы: