Heat-N-Glo AT-GRAND Скачать руководство пользователя страница 2

i

SAFETY AND WARNING INFORMATION

READ 

and 

UNDERSTAND 

all instructions carefully before starting the installation.

FAILURE TO FOLLOW 

these installation instructions may result in a possible fire

hazard and will void the warranty.

Prior to the first firing of the fireplace, 

READ 

the Using Your Fireplace section of the

Owners Guide

.

DO NOT USE 

this appliance if any part has been under water. Immediately 

CALL 

a

qualified service technician to inspect the unit and to replace any part of the control

system and any gas control which has been underwater.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED 

by a qualified service person. The

appliance and venting system should be 

INSPECTED 

before initial use and at least

annually by a professional service person. More frequent cleaning may be required due

to excessive lint from carpeting, bedding material, etc. It is 

IMPERATIVE 

that the unit’s

control compartment, burners, and circulating air passageways 

BE KEPT CLEAN 

to

provide for adequate combustion and ventilation air.

Always 

KEEP 

the appliance clear and free from combustible materials, gasoline, and

other flammable vapors and liquids.

NEVER OBSTRUCT 

the flow of combustion and ventilation air. Keep the front of the

appliance 

CLEAR 

of all obstacles and materials for sevicing and proper operations.

Due to the high temperature, the appliance should be 

LOCATED 

out of traffic areas

and away from furniture and draperies. Clothing or flammable material 

SHOULD NOT

BE PLACED 

on or near the appliance.

Children and adults should be 

ALERTED 

to the hazards of high surface temperature

and should 

STAY AWAY 

to avoid burns or clothing ignition. Young children should be

CAREFULLY SUPERVISED 

when they are in the same room as the appliance.

These units 

MUST 

use one of the vent systems described in the Installing the

Fireplace section of the 

Installers Guide

NO OTHER 

vent systems or components

MAY BE USED

.

This gas fireplace and vent assembly 

MUST 

be vented directly to the outside and

MUST NEVER 

be attached to a chimney serving a separate solid fuel burning

appliance. Each gas appliance 

MUST USE 

a separate vent system. Common vent

systems are 

PROHIBITED

.

INSPECT 

the external vent cap on a regular basis to make sure that no debris is

interfering with the air flow.

The glass door assembly 

MUST 

be in place and sealed, and the trim door assembly

MUST 

be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE 

this appliance with the glass door removed, cracked, or broken.

Replacement of the glass door should be performed by a licensed or qualified service

person. 

DO NOT 

strike or slam the glass door.

The glass door assembly 

SHALL ONLY 

be replaced as a complete unit, as supplied

by the gas fireplace manufacturer. 

NO SUBSTITUTE 

material may be used.

DO NOT USE 

abrasive cleaners on the glass door assembly. 

DO NOT ATTEMPT 

to

clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is recommended that a qualified

service technician perform an appliance check-up at the beginning of each heating

season.
Any safety screen or guard removed for servicing must be replaced before operating

this appliance.

!

!

!

!
!

!

!

!

!

!

!

!

!

!

!

!

!

!

Содержание AT-GRAND

Страница 1: ...r gases unless a certified kit is used Please contact your Heat N Glo Fireplace dealer for any questions or concerns For the number of your nearest Heat N Glo dealer please call 612 890 8367 Printed i...

Страница 2: ...E PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAR...

Страница 3: ...ystem Approvals 6 Step 2 Positioning Leveling and Securing the Insert 10 Step 3 The Gas Control Systems 10 Step 4 The Gas Supply Line 11 Step 5 Gas Pressure Requirements 12 Step 6 Wiring the Appliance...

Страница 4: ...to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada HighAltitude Installations U L Listed gas appliances are tested...

Страница 5: ...s The gas logs are packaged separately and must be field installed Read all of the instructions before starting the installation Follow these instructions carefully during the installation to ensure m...

Страница 6: ...PARTS HAVE BEEN REPLACED AND THE FIREPLACE HAS BEEN REAPPROVED BY THE AUTHORITY HAVING JURISDICTION 4 The solid fuel fireplace s flue damper must be fully locked in the open position or removed for in...

Страница 7: ...as a wall switch or remote control are desired Figure 1 Diagram of the AT GRAND TOP VIEW MINIMUM FIREPLACE SIZE FRONT WIDTH 33 839mm REARWIDTH 24 610mm DEPTH 131 2 343mm HEIGHT 24 610mm NOTE If exhaus...

Страница 8: ...stion air and exhaust vent pipes NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction wit...

Страница 9: ...inating the inlet air vent pipe just above the damper These two kits are recommended for zero clearance factory built woodburning fireplaces Connecting the Vent Pipe Install the 3 inch flexible vent p...

Страница 10: ...OTE This also pertains to vertical vent systems installed on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 to...

Страница 11: ...NECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP OR TERMINATED IN THE CHIMNEY This option shows both exhaust and inlet air vent pipes attac...

Страница 12: ...9 Figure 4 Figure 5 EXHAUST STARTING COLLAR INLET AIR STARTING COLLAR...

Страница 13: ...ntrol Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The gas control systems used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt con...

Страница 14: ...lugged tapping acces sible for test gauge connection should be provided for in the gas supply line leading to the unit s shut off valve Locate the gas line access hole in the outer casing of the inser...

Страница 15: ...k open the screw in the center of the tap Position a rubber hose over the tap to obtain the pressure reading The fireplace and its individual shut off valve must be disconnected from the gas supply pi...

Страница 16: ...the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE W...

Страница 17: ...ed to be positioned If the logs have been packaged separately refer to the installation instructions that accompany the logs Save the log instructions with this manual If sooting occurs the logs might...

Страница 18: ...cing Replace the glass door Reset the four glass eye bolts be sure they are securely latched Replace the trim door 1 Lift the top trim door up and out of the unit 2 Pull out and rotate the glass relea...

Страница 19: ...insert See Figure 12 2 Disconnect the ON OFF switch from the low voltage wire leads and insert the short wires of the ON OFF switch through the hole at the upper right corner of the surround and push...

Страница 20: ...ace of the unit aligning the holes in upper and lower right and left corners and secure the surround to the unit with the attachment screws NOTE PLACE THE THREE INSULATION PIECES INTO THE CAVITIES AT...

Страница 21: ...all amount of air will be in the gas supply lines When first lighting the appliance it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the appliance...

Страница 22: ...e information see Placing Ember Material in the INSTALLERS GUIDE Cleaning Once annually Qualified Brush or vacuum the control Burner Service compartment fireplace logs and Controls Technician burner a...

Страница 23: ...20 STANDING PILOT 3 8 10 mm Figure 14 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Figure 15 Pilot Ignitor Flame Patterns...

Отзывы: