19

Glass Specifications:   24 1/2  X  35 1/2    TEMPERED

CAUTION: IT IS STRONGLY RECOMMENDED THAT

TRIM DOORS WITH OPTIONAL MESH SCREENS BE IN-

STALLED ON PROPANE MODELS.

Figure 16.   Placement of the Ember Material

Figure 15.  Glass Assembly

7000TV

6000TVB

Step 12.  Before Lighting  the Fireplace

Before

 lighting the fireplace, be sure to do the following:

Remove all paperwork from underneath the fireplace.
Review safety warnings and cautions

• Read the 

Safety and Warning Information

 section at

the beginning of this 

Installers Guide

.

Double-check for gas leaks

• Before lighting the fireplace, double-check the unit for

possible gas leaks.

Double-check vent terminations and front grilles for

obstructions.

• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent ter-

minations or the front grilles.

Double-check for faulty components

• Any component that is found to be faulty 

MUST BE

 re-

placed with an approved component. Tampering with the

fireplace components is 

DANGEROUS

 and voids all war-

ranties.

A small amount of air will be in the gas supply lines. When

first lighting the fireplace, it will take a few minutes for the

lines to purge themselves of this air. Once the purging is

complete, the fireplace will light and will operate normally.
Subsequent lightings of the fireplace will not require this

purging of air from the gas supply lines,

 unless

 

the gas

valve has been turned to the OFF position

, in which

case the air would have to be purged.

NOTE:

 The fireplace should be run for 8 hours on the initial

start-up. This will help to cure the chemicals used in the

paint and logs.

!

!

Step 13.   Lighting the Fireplace

You’ve reviewed all safety warnings, you’ve checked the

fireplace for gas leaks, you know the vent system is

unobstructed, and you’ve checked for faulty components.

Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’S

MANUAL FOR ALL CAUTIONS, SAFETY,  AND

WARNING INFORMATION PERTAINING TO THE

LIGHTING AND OPERATION OF THE FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH

THE APPLIANCE FOR FUTURE REFERENCE.

Содержание 6000TVB

Страница 1: ...R Underwriters Laboratories Listed 522 902F 9 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your Heat N Glo dealer for any questions or concerns For the number of your nearestHeat N Glodealer pleasecall952 985 6000 Printed in U S A Copyright 2000 Heat N Glo a division of Hearth Technologies In...

Страница 2: ...the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control sy...

Страница 3: ...4 Installing the Vent System 13 A Vent System Approvals 13 B System Components 13 C Bedroom Installation in Canada 14 D Vent Termination 14 Step 5 Positioning Leveling and Securing the Fireplace 14 Step 6 The Gas Control Systems 14 Step 7 The Gas Supply Line 15 Step 8 Gas Pressure Requirements 15 Step 9 Wiring the Fireplace 16 Step 10 Finishing 18 Step 11 Installing Trim Logs and Ember Material 18...

Страница 4: ... Codes current edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space These models natural gas and propane can be installed in a bedroom in Canada if a thermostat Model WH STAT is installed with the unit Consult local code authorities Detailed installation instructions for Model WH STAT a...

Страница 5: ...t Failure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructed by Heat N Glo Improper positioning ...

Страница 6: ...10 Figure 1 Diagram of the 7000TV and 6000TVB GAS ACCESS GAS CONTROLS RATING PLATES LABELS VENT COLLARS HOOD STANDOFFS BOTTOM GRILLE COVER ELECTRICAL ACCESS OUTSIDE AIR ...

Страница 7: ...e inch 25mm The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construction NOT from the screw heads that secure the unit together A 42 B 38 1 2 C 22 Figure 3 Framing Dimensions Minimum Clearances from the B Type Vent Pipe to Combustible Materials is 1 inch 25mm all around the pipe Step 2 Framing the Fireplace Fireplace fram...

Страница 8: ...echanically or passively balanced to allow atmospherically vented appliances such as top vented gas fireplaces with draft hoods to draft properly If the home experiences negative pressure or is likely to experience negative pressure connection to an outside air source is mandatory Installing Optional Outside Make up Air This unit is equipped to accept outside air By using outside make up air the a...

Страница 9: ...h the holes in the 10 5 8 ring to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system if possible A 90 degree elbow can be attached directly to the unit If it is it can be followed by a MAXIMUM 15 feet horizontal run a second 90 degree elbow ending in a minimum 30 foot v...

Страница 10: ...ring the Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non combustible material such as sheet metal as necessary Secure the fireplace to the framing by nailing or screwing Figure 7 Proper Positioning Leveling and Securing of a Fireplace Step 6 The Gas ...

Страница 11: ...rements Pressure requirements for Heat N Glo gas fireplaces are shown in the table below Pressure Natural Gas Propane Minimum 5 0 inches 11 0 inches Inlet Pressure w c w c Maximum Inlet 14 0 inches 14 0 inches Gas Pressure w c w c Manifold 3 5 inches 10 0 inches Pressure w c w c A one eighth 1 8 inch 3 mm N P T plugged tapping is provided on the inlet and outlet side of the gas control for a test ...

Страница 12: ...r chute and install the blower YOU MUST REPLACE THE AIR CHUTE AFTER INSTALLATION Remote Wall Switch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED CAUTION ...

Страница 13: ...ab into the pilot hole on the outer wrap Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 12 Direct Spark Ignition DSI Wiring Diagram Remote Wall Switch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less of 16A W G minimum wire and connect it to the fireplace ON OFF...

Страница 14: ...LES IN ANY MANNER Install optional marble and brass trim surround kits as desired Marble brass brick tile or other non combustible materials can be used to cover up the gap between the sheet rock and the fireplace Do not obstruct or modify the air inlet outlet grilles When overlapping on both sides leave enough space so that the bottom grille can be lowered and the trim door removed Positioning th...

Страница 15: ... component Tampering with the fireplace components is DANGEROUS and voids all war ranties A small amount of air will be in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace will light and will operate normally Subsequent lightings of the fireplace will not require this purging o...

Страница 16: ...ly By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the flames are steady not lifting or floating See Figure 17 The flame sensor DSI or thermopile...

Отзывы: