MODEL

    FLUE TERMINATION APPROVALS

6000TRS-AUB           DVP-TRAP,   DVP-TVHW

TABLE 1

STRAIGHT OUT HORIZONTAL FLUE SYSTEM

Figure 6 shows straight out horizontal flue systems
approved for use on this model.

ELBOWS

The flue systems installed on this gas heater may also
include one (1), two (2), or three (3) 90 - degree elbow
assemblies.

Figures 6 through 13 and their corresponding tables
show examples of flue configurations using elbows.
The relationships of vertical rise to horizontal run in
flue configurations using elbows 

MUS

T be strictly ad-

hered to.

NOTE:

TWO 45-DEGREE ELBOWS MAY BE USED

IN PLACE OF ONE 90 -DEGREE ELBOW.

CAUTION:

 DO NOT  INSTALL A 45-DEGREE ELBOW

DIRECTLY TO THE HEATER FOR A CORNER INSTAL-
LATION. USE TWO 90-DEGREE ELBOWS.

ONE (1) 90-DEGREE ELBOW

Figures 7 and 8 show an installation using one (1) 90-
degree elbow. Dimension V is listed as 

MINIMUM 

ver-

tical dimensions and dimension H is listed as corre-
sponding 

MAXIMUM

 horizontal dimensions.

TWO (2) 90-DEGREE ELBOWS

Figures 9 and 10 show examples of possible installa-
tions using two (2) 90-degree elbows. Dimension V is
listed as 

MINIMUM 

vertical dimensions, dimension H

is listed as 

MAXIMUM 

beginning horizontal dimen-

sions, and dimension H+H

1

 is listed as corresponding

TOTAL MAXIMUM 

horizontal dimensions.

THREE (3) 90-DEGREE ELBOWS

Figures 11 through 13 show examples of possible in-
stallations using
three (3) 90-de-
gree elbows. Di-
mensions V are
listed 

MINIMUM

first vertical di-
mensions and
d i m e n s i o n s   H
are listed as be-
ginning 

MAXI-

MUM

 horizontal

dimensions. Di-
mensions H+H

1

and

 

H+H

1

+H

 are

listed as 

TOTAL

MAXIMUM

 hori-

zontal dimen-
sions. Dimen-
sions V+V

are

listed as 

TOTAL

MAXIMUM

 verti-

cal dimensions.

FIGURE 5

V

CAP

V

MAX. RUN

36 FT.

(10.9m)

FIGURE 4

1.3   

FLUE  SYSTEM  APPROVALS AND

         INSTALLATIONS

This model is approved to use DVP-Series flue pipe
components. A DVP-TRAP Termination Cap must be
used to terminate flue systems in a horizontal position.
A DVP-TVHW vertical Termination Cap must be used to
terminate flue systems in a vertical position.

Figures 5 thru 14 show the flue systems approved for
these models. Approved flue system components are
labeled for identification. 

NO OTHER FLUE SYSTEMS

OR COMPONENTS MAY BE USED.

 Detailed installa-

tion instructions are included with each flue termination
kit and should be used in conjunction with this manual.

WARNING: THIS GAS  APPLIANCE  AND FLUE  AS-
SEMBLY MUST BE FLUED DIRECTLY TO THE OUT-
SIDE AND MUST NEVER BE ATTACHED TO A CHIM-
NEY SERVING A SEPARATE SOLID FUEL BURNING
APPLIANCE.  EACH GAS APPLIANCE MUST USE A
SEPARATE FLUE SYSTEM-COMMON FLUE SYS-
TEMS ARE PROHIBITED.

CAUTION: UNDER NO CONDITION SHOULD COM-
BUSTIBLE MATERIAL BE CLOSER THAN 3 INCHES
(2 1/2 INCHES  AT   WALL FIRESTOPS) FROM THE
TOP OF THE 8 INCH PIPE OR 1- INCH TO THE SIDES
AND THE BOTTOM FOR HORIZONTAL SECTIONS OF
THIS FLUE SYSTEM. VERTICAL SECTIONS OF THIS
SYSTEM REQUIRE A MINIMUM OF 1- INCH CLEAR-
ANCE TO COMBUSTIBLE MATERIALS ALL AROUND
THE 8 INCH PIPE.

For alternative installations, other than depicted, con-
tact your dealer for further information.
Refer to Figure 4 for required clearances to flue terminals.

STRAIGHT UP VERTICAL FLUE SYSTEM

Figure 5 shows straight up vertical flue system approved
for use on this model.

VERTICAL FLUE RESTRICTOR

If the heater installation requires a vertical flue exceed-
ing 4.5m above the unit with no horizontal flue or el-
bows a vertical flue restrictor must be installed (see
Figure 4).

RESTRICTOR

PLATE

Содержание 6000TRS-AUB

Страница 1: ...044 USA 1 888 427 3973 2022 900F 7 04 INSTALLATION AND OPERATION INSTRUCTIONS This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 52...

Страница 2: ...ual Report to your dealer any parts dam aged in shipment specifically check glass condi tion The gas logs and flue system components are in separate packages Read all instructions before INSTALLATION...

Страница 3: ...staller Testing 21 2 0 OPERATING INSTRUCTIONS 21 2 1 Safety and Lighting Information 23 2 2 Safety Information 23 2 3 Lighting Instructions 24 2 4 Fan Operation 25 3 0 SERVICING AND MAINTENANCE 25 3 1...

Страница 4: ...r remote control are desired If the heater is to be installed on carpeting or tile or on any combustible material other than wood flooring the heater should be installed on a metal or wood panel that...

Страница 5: ...Locating the Heater The diagram See figure 2 shows space and clearance requirements for locating a heater within a room Minimum Clearances from the Heater to Combustible Materials Glass Back of Sides...

Страница 6: ...ERIFY FRAMING METHODS AND WALL COVER ING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS NOTE Dimension B taken from finished hearth frame Dimensions D and E taken from bottom of unit For minimum clearance...

Страница 7: ...input 300 Appliances over 50 MJ h input 500 b From the ground or above a balcony 300 c From a return wall or external corner 500 d From a gas meter M 1000 e From an electricity meter or fuse box P 50...

Страница 8: ...are listed as TOTAL MAXIMUM verti cal dimensions FIGURE 5 V CAP V MAX RUN 36 FT 10 9m FIGURE 4 1 3 FLUE SYSTEM APPROVALS AND INSTALLA TIONS This model is approved to use DVP Series flue pipe component...

Страница 9: ...M V FT H FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m V H 24 MAX 7 3m H 8 MAX 2 4m FIGURE 8 Flueing with One 90 Elbow NOTE If a 90o elbow is first...

Страница 10: ...3 MIN 914mm 4 MAX 1 22m 12 MAX 3 72m 4 MIN 1 22m 6 MAX 1 8m 16 MAX 4 9m 20 MAX 6 1m 6 MAX 1 8m 16 MAX 4 9m FIGURE 10 Flueing with Two 90 Elbows V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2...

Страница 11: ...3 6 m 4 MIN 1 22 m 8 MAX 2 48 m 16 MAX 4 9 m 8 MAX 2 48 m 16 MAX 4 9 m NOTE V V MAX 36 10 9 m FLUEING WITH THREE 3 90 ELBOWS FIGURE 11 Flueing with three 90 elbows V H H H1 H2 1 MIN 305 mm 2 MAX 610...

Страница 12: ...914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m NOTE H H1 16 MAX 4 9m V V1 H H1 36 MAX 10 9m V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m H H1...

Страница 13: ...ling Flue Components After determining which set of starting collars will be used top or rear follow flueing instructions accordingly Flueing Out the Rear Flue Remove the installed rear seal cap from...

Страница 14: ...pre viously cut and secure the firestops with nails or screws The pipe opening of the firestops MUST BE placed towards the bottom of the firestop Continue the flue run through the firestop FIGURE 18...

Страница 15: ...me manner The heat shield sections will overlap to match the wall thickness depth The small leg in the shield rests on top of the flue to properly space it from the pipe section see Figure 22 JOIST CE...

Страница 16: ...ical flue pipe to combus tible materials Mark the roof hole accordingly Cover the opening of the installed flue pipes Cut and frame the roof hole Use framing lumber the same size as the roof rafters a...

Страница 17: ...E BRN BR N BLUE GRD BLUE JUNCTION BOX DETAIL FAN TEMPERATURE SENSOR SWITCH FAN SPEED CONTROL JUNCTION BOX 1 5 FAN These heaters have a factory installed Fan Electrical Junction Boxes variable speed Rh...

Страница 18: ...SEALED A 150 C MINIMUM SEALANT MATERIAL MUST BE USED THESE JOINTS ARE NOT REQUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 150 C MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED A S FACING TO THE F...

Страница 19: ...cate log 1 on grate with notches and push log against rear log locators LOG 2 SRV382 702 Locate log 2 on grate with notches Slide left end of log forward and right side back against tab Log Assembly L...

Страница 20: ...the right end on top of log 2 LOG 5 SRV382 705 Place bottom of log 5 between the 4th and 5th grate bars and rest the top onto log 1 LOG 6 SRV438 724 Place the Y shaped part of log 6 over the 3rd grate...

Страница 21: ...he building WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The control system for this model is a millivolt type It consists of a gas control valve variable regulator a stand ing pilot assembly a th...

Страница 22: ...E THE UNIT CAN BE PLACED INTO SAFE OP ERATION DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE UNIT AND TO REPLACE ANY PART OF...

Страница 23: ...has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the gas control system which has been under water 2 1 SAFETY LIGHTING INFORMATI...

Страница 24: ...houldnotrequireaccessingforlighting purposes The pilot is located inside the combustion chamber THERMOPILE PILOT BURNER 6 To put the control in the pilot position turn the control knob counter clockwi...

Страница 25: ...sh ing at least twice a year CAUTION THE LOGS GET VERY HOT HANDLE ONLY WHEN COOL WARNING DO NOT USE ABRASIVE CLEANERS ON THE GLASS DOOR ASSEMBLY DO NOT ATTEMPT TO CLEAN THE GLASS DOOR WHEN IT IS HOT F...

Страница 26: ...m the underside of the thermopile The thermopile can then be sepa rated from the pilot bracket Unscrew the pilot assembly bracket and remove NOTE When removing the pilot assembly carefully pull the el...

Страница 27: ...gnitor 1 Using a match light pilot If pi lot lights turn off pilot and trig ger the red or black button again If pilot lights an improper gas air mixture caused the bad light ing and a longer purge pe...

Страница 28: ...micro switch and connect to terminal TP on the gas valve Turn green knob to pilot position depress and light pilot light If meter reading is greater than 325 m v after 30 seconds the pilot generator i...

Страница 29: ...allow for igni tion or the heater continues to shut off disconnect the limit switch wire from the gas valve and repeat the lighting instruc tions If the pilot and burner re main lit after the heater...

Страница 30: ...debris or blockage 1 Adjust the log set so that the flame does not impinge on it 1 Adjust the air shutter at the base of the burner 1 Inspect the opening at the base of the burner It is imperative th...

Страница 31: ...31 6000TRS AUB Exploded Parts Diagram 4 0 Replacement Parts Service Parts List on following page 21 Log set assembly 27 24 26 25 22 23 5 16 17 2 1 19 20 3 15 14 13 12 18 4 7 6 8 11 9 10 29 28 30 31...

Страница 32: ...9 13 Blower Assembly 240v 100 505A 14 Junction Box 546 250A 15 Cord 546 251A 16 Pilot Assembly NG 530 510A Pilot Assembly LP 530 511A 17 ON OFF Rocker Switch 060 511 18 Heat Shield Baffle 2022 100 19...

Страница 33: ...t the current wholesale price defective electrical or manual components optional components or accessories and glass panels not including glass panels broken during misuse or careless handling HEAT N...

Отзывы: