background image

3

TABLE OF CONTENTS

INTRODUCTION

Thank  You 

for  purchasing  this  water  heater.    Properly 

installed and maintained, it should give you years of trouble-

free service.

Abbreviations found in this instruction manual include:

ANSI - American National Standards Institute

AHRI - Air Conditioning, Heating, and Refrigeration 

Institute.

NEC - National Electrical Code

NFPS - National Fire Protection Association
UL - Underwriter’s Laboratory

PREPARING FOR THE INSTALLATION

1. Read the “General Safety Information” section of this 

manual first, then read the rest of the manual carefully.  

If you don’t follow the safety rules, the water heater may 

not operate safely.  It could cause DEATH, SERIOUS 

BODILY INJURY, AND/OR PROPERTY DAMAGE.

  This manual contains instructions for the installation, 

operation, and maintenance of the electric water heater.  

It also contains warnings throughout that must be read 

and understood.  All warnings and all instructions are 

essential to the proper operation of the water heater and 

your safety.  

READ THE ENTIRE MANUAL BEFORE 

ATTEMPTING TO INSTALL OR OPERATE THE WATER 

HEATER.

  Be sure to turn off all power when working on or 

near the electrical system of the heater.  Never touch 

electrical components with wet hands or when 

standing in water.

  When replacing fuses, always use the correct size for the 

circuit.

  The model and rating plates on page 5 interprets 

certain markings into useful information.  Both of these 

references should be used to identify the heater, its 

components, and optional equipment.

2. The installation must conform with these instructions 

and the local code authority having jurisdiction and the 

requirements of the power company.  In the absence of 

local codes, the installation must comply with the latest 

editions of the National Electrical Code, NFPA 70 or the 

Canadian Electrical Code CSA C22.1.  The National 

Electrical Code may be ordered from : 

   

National Fire Protection Association

   

1 Batterymarch Park

   

Quincy, MA 02269

  The Canadian Electrical Code is available from:
   

Canadian Standards Association

   

8501 East Pleasant Valley Rd.

   

Cleveland OH, 44131

3. If after reading this manual you have any questions or do 

not  understand any portion of the instructions, call the 

toll free number listed on the back cover of this manual 

for technical assistance.

  A sample rating plate is shown on page 5.  In order to 

expedite your request, please have full model and serial 

number available for the technician.

4. Carefully plan your intended placement of the water 

heater.  Examine the location to ensure the water heater 

complies with the “Locating the Water Heater” section of 

this manual.

  Installation and service of this water heater requires 

ability equivalent to that of a licensed tradesman or 

qualified agency (page 2) in the field involved.  Plumbing 

and electrical work are required.

WARNING

Before removing any access panels 

or servicing the water heater, make 

sure the electrical supply to the 

water is turned OFF.
Failure to do this could result in 

death, serious bodily injury, or 

property damage.

SAFETY INFORMATION  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - 2

INTRODUCTION   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3

DIMENSIONS & CAPACITIES DATA   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4

APPROVALS  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  5

MODEL AND RATING  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  5

FEATURES & COMPONENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  6

LOCATING THE WATER HEATER  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  7

INSTALLATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  7 - 9

ELECTRICAL  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  9 - 11

WIRING DIAGRAMS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  10

OPERATION   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  12

TEMPERATURE REGULATION  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  13

MAINTENANCE  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  14

TROUBLESHOOTING- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  14 - 15

LEAKAGE CHECKPOINTS  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  15

REPLACEMENT PARTS  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  15 - 16

LIMITED WARRANTY  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  17

Содержание SSL-10

Страница 1: ...truction manual and the safety messages herein before installing operating or servicing this water heater Failure to follow these instructions and safety messages could result in death or serious injury This manual must remain with the water heater WARNING If the water heater becomes immersed in water up to or above the level of the bottom of the element doors the heater should be examined by a qu...

Страница 2: ...uation which if not avoided could result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage All safety messages will generally tell you about the type of hazard what can happen if you do not follow the safety message and how to avoid the risk of injury IMPORTANT DEFINITIONS Qualif...

Страница 3: ...LD BE NO SMOKING OR OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN WARNING EXPLOSION HAZARD Flammable hydrogen gases may be present Keep all ignition sources away from faucet when turning on hot water When servicing this unit verify the power to the unit is turned off prior to opening the control cabinet door WARNING EXPLOSION HAZARD Overheated water can cause water tank explosion Properly size...

Страница 4: ...de authority having jurisdiction and the requirements of the power company In the absence of local codes the installation must comply with the latest editions of the National Electrical Code NFPA 70 or the Canadian Electrical Code CSA C22 1 The National Electrical Code may be ordered from National Fire Protection Association 1 Batterymarch Park Quincy MA 02269 The Canadian Electrical Code is avail...

Страница 5: ... F 40 F 54 F 60 F 72 F 80 F 90 F 100 F 108 F 120 F 126 F Non Simultaneous Operation 1500 1 5 17 15 11 10 8 8 7 6 6 5 5 2000 2 0 23 20 15 14 11 10 9 8 8 7 6 2500 2 5 28 25 19 17 14 13 11 10 9 8 8 3000 3000 3 0 34 30 23 20 17 15 14 12 11 10 10 4000 4000 4 0 45 41 30 27 23 20 18 16 15 14 13 4500 4500 4 5 51 46 34 30 25 23 20 18 17 15 14 5000 5000 5 0 56 51 38 34 28 25 23 20 19 17 16 6000 6000 6 0 68 ...

Страница 6: ...ER WATTS LOWER CIRCUIT INTERLOCK 1 PH 3 PH 1 PH 3 PH RATED CAPACITY WORKING PRESSURE MAX PSI WATTS TOTAL WATTS CONNECTED STANDBY LOSS Conforms to UL 1453 Certified to CAN CSA STD C22 2 No 110 94 MASS Approval P1 0119 315 SSL 10 20 30 40 50 SSN 40 50 60 80 119 Conforms to UL1453 for Electric Commercial Water Heaters Certified to CAN CSA STD C22 2 No 110 94 ...

Страница 7: ...RAIN VALVE T P VALVE MUST BE PIPED A MAX OF 6 FROM FLOOR DRAIN SHUTOFF VALVE WATTS LF301 DIELECTRIC UNION W 4 CU TUBE SUPPLIED W UNIT COLD WATER INLET HOT WATER SUPPLY ACCESS PANEL T P VALVE WATTS 3 4 LF301 DIELECTRIC UNION W 4 CU TUBE SUPPLIED W UNIT INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES INSTALL THERMAL EXPANSION TANK IF CHECK VALVE OR PRESSURE REDUCING VALVE I...

Страница 8: ... replaceable parts such as thermostats drain valve and relief valve Adequate clearance for servicing this water heater should be considered before installation such as changing the anodes etc CAUTION PROPERTY DAMAGE HAZARD All water heaters eventually leak Do not install without adequate drainage INSTALLATION REQUIRED ABILITY Installation and service of this water heater requires ability equivalen...

Страница 9: ...ter heater is provided with a properly rated sized and certified combination Temperature and Pressure Relief Valve The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief Valves for Hot Water Supply Systems ANSI Z21 22 CSA 4 4 and the code requirements of ASME If re...

Страница 10: ...al and replace the T P Valve with a properly rated sized new one If you do not understand these instructions or have any questions regarding the T P Valve call the toll free number listed on the back cover of this manual for technical assistance CLOSED WATER SYSTEMS Water supply systems may because of code requirements or such conditions as high line pressure among others have installed devices su...

Страница 11: ...element heater equipped with high limit control and single phase power input 2 Four wire H 8 circuit for dual element heater equipped with two high limit controls single phase or three phase power input The heater with dual elements is factory wired for connection to a three wire three phase delta branch circuit non sumultaneous operation In addition a ground conductor is required Element connecti...

Страница 12: ...t Burial Based on Ambient Temperature of 86 F These ampacities relate only to conductors described in Table 310 13 in Code For ambient temperatures that over 86 F see Correction Factors Note 13 in Code Size Temperature Rating of Conductor See Table 310 13 in Code AMG MCM 140 F 167 F Types RUW 14 2 T TW UF Types RH RHW RUH 14 2 THW THWN XHHW USE 18 16 14 15 15 12 20 20 10 30 30 8 40 45 6 55 65 4 70...

Страница 13: ...sary 3 DepresstheredmanualresetbuttononeachThermostat ECO combination control See Figure 5 6 7 or 8 4 Turn on the electrical disconnect switch 5 Observe the operation of the electrical components during the first heating cycle Use care as the electrical circuits are energized 6 Close the front panel or top access cover Temperature control and contactor operation should be checked by allowing heate...

Страница 14: ...for these three settings are LO 140 F MED 160 F HI 181 F These thermostats are set from the factory at the LO setting The over temperature device ECO High Limit attached to each thermostat has a manual reset The H 2 circuit thermostat is adjustable from approximately 130 F to 170 F see Figure 6 these thermostats are set from the factory at approximately the 125 F setting The over temperature devic...

Страница 15: ...tify and locate water heater components NOT ENOUGH OR NO HOT WATER 1 Be certain the electrical disconnect switch serving the water heater is in the ON position 2 Check the fuses The electrical disconnect switch usually contains fuses 3 If the water was excessively hot and is now cold the high limit switch may have activated Large demands require a recovery period to restore water temperature 4 The...

Страница 16: ...ruction Manual for assistance in locating a service agency in your area REPLACEMENT PARTS Call the phone number on the back cover of this Instruction Manual for assistance in locating replacement parts When ordering parts specify complete model no see rating plate quantity and name of the part desired Standard hardware items should be purchased locally TROUBLESHOOTING CHECKLIST CONTINUED LEAKAGE C...

Страница 17: ... ELEC_EL 208V1500W 2 0 2000 ELEC_EL 208V2000W 2 5 2500 ELEC_EL 208V2500W 3 0 3000 ELEC_EL 208V3000W 4 5 4500 ELEC_EL 208V4500W 5 0 5000 ELEC_EL 208V5000W 5 5 5500 ELEC_EL 208V5500W 6 1 6100 ELEC_EL 208V6100W 240 1 5 1500 ELEC_EL 240V1500W 2 0 2000 ELEC_EL 240V2000W 2 5 2500 ELEC_EL 240V2500W 3 0 3000 ELEC_EL 240V3000W 4 5 4500 ELEC_EL 240V4500W 5 0 5000 ELEC_EL 240V5000W 5 5 5500 ELEC_EL 240V5500W...

Страница 18: ...r taste of water Failure to conduct authorized factory start up if required Alterations to the water heater Non outdoor heaters installed outdoors Damages due to a failure to allow for thermal expansion Heat exchanger failure due to lack of adequate proper supply of water Heaters moved from their original location Service trips to explain proper installation use or maintenance of the product unit ...

Страница 19: ...18 ...

Страница 20: ...HEAT FLO INC P O BOX 612 UXBRIDGE MA 01569 508 278 2400 www heat flo com ...