WATER   TEMPERATURE   ADJUSTMENT   

It   is   recommended   that   the   thermostat   be   set   for   the   lowest   possible   temperature   that   satisfies   
your   needs.   This   will   also   provide   you   with   the   lowest   energy   consumption   and   cost.   
Check    the    water    temperature    at    a    hot    water    faucet    soon    after    the    tank    thermostat    has   
satisfied,   and   the   circulator   and   the   boiler   have   turned   off.   Adjust   as   needed.   
Lowering   the   thermostat   setting   will   not   have   an   immediate   effect   on   the   water   temperature   
because   the   stored   water   will   have   to   be   used   and   the   thermostat   must   go   through   the   cycle   of   
heating    cold    water    and    satisfying    at    the    new,    lower    temperature.    Additional    temperature   
checks   should   follow   the   completion   of   a   heating   cycle.   Further   adjustments   may   be   required   
after   you   have   used   the   water   heater.   
   

   

The    table    below    details    the    approximate   
relationship    of    water    temperature    and    time   
with   regard   to   scald   injury   and   may   be   used   as   
a    guide    in    determining    the    safest    water   
temperature   for   your   applications.   
   

   

   

The    scald    label    shown    to    the    right    can    be   
found    on    all    Heat-­‐Flo    Indirect    Water    Heaters   
and   Storage   tanks.      Take   note   and   use   caution   
when   adjusting   the   temperature   settings   with   
your   water   system.      Be   sure   to   always   feel   the   
water   before   bathing   or   showering,   especially   
when   drawing   a   bath   for   an   infant   or   elder.         

   

–   

Important   WARNING   information   on   Pg.   18.

   –

 

   

Содержание 115-D

Страница 1: ...ovided to assist in enabling the installation operation and maintenance of this water heater For your comfort safety and convenience we recommend that this water heater be installed and serviced by a...

Страница 2: ......

Страница 3: ...evere personal injury death or substantial property damage if ignored Indicates the presence of a hazard which can cause severe personal injury death or substantial property damage if ignored Indicate...

Страница 4: ...Installation Considerations 3 Dimensions and Capacities 4 Piping 10 13 Electrical 14 16 18 Operation 14 Important Scalding Information 14 15 Maintenance 19 21 Troubleshooting 22 Boiler Supply Ratings...

Страница 5: ...temperature relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relie...

Страница 6: ...ater NEVER leave a child or disabled person unattended in a bathtub or a shower IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER WARNING When using electrical applian...

Страница 7: ...hot tubs and the use of more than one shower at a time Increase the tank size if these factors are present Consult ASHRAE sizing guides and other references Dimensions weights ratings and capacities...

Страница 8: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 4 Heat Exchanger Coil Output TABLE 1 TABLE 2...

Страница 9: ...for each zone and the water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing PRIORITY OR NON PRIORITY FOR H...

Страница 10: ...e are Bottom 0 Left Right and Rear Sides 3 Front 30 Top 6 ADDITIONAL RECOMMENDED COMPONENTS 1 Shut Off Valves Allows the isolation of the water heater from the boiler system during service 2 Unions Al...

Страница 11: ...ppm Heat Flo s standard warranty does not cover problems caused by improper water Ph or excessive levels of chlorides Damage to tanks caused by improper water quality is not covered under the warrant...

Страница 12: ...and the discharge line The discharge opening must not be subjected to blockage or freezing DO NOT thread plug or cap the discharge line It is recommended that a minimum clearance of four 4 inches be...

Страница 13: ...The use of a check valve is required to prevent back flow through the water heater during operation of the space heating system ZONE VALVE SYSTEM For a space heating system that uses Zone Valves refer...

Страница 14: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 10 Indirect Piping...

Страница 15: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 11 Indirect Piping...

Страница 16: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 12 Solar Piping...

Страница 17: ...The location of the tapping will not allow for the mixing of back up heated hot water boiler indirect of electric element into the lower solar heated section of the tank When an anti scald device is i...

Страница 18: ...e tank has reached the temperature setting the tank thermostat opens and de energizes the circulator and the boiler If there is a call for space heating the boiler will continue to run until the room...

Страница 19: ...hrough the cycle of heating cold water and satisfying at the new lower temperature Additional temperature checks should follow the completion of a heating cycle Further adjustments may be required aft...

Страница 20: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 16 Indirect Wiring...

Страница 21: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 17 Indirect Wiring...

Страница 22: ...tion point for connecting a ground wire All wiring shall be done in accordance with all applicable local and state codes Adjusting the Temperature Dial on the Thermostat The minimum potable water temp...

Страница 23: ...kage at the joints unions and shut off valves Repair as required 2 Temperature and Pressure Relief Valve Annual The temperature and pressure relief valve should be checked to ensure that it is in oper...

Страница 24: ...il and the thermostat 6 Using a funnel pour one gallon of commercial ice maker cleaning solution into the tank through the relief valve opening Follow the instructions cautions and warnings supplied w...

Страница 25: ...temperature control can be turned to the side to allow easier access 4 After the water heater has drained and cooled remove the anode using a 1 6 point socket and a breaker bar 5 Inspect the anode an...

Страница 26: ...ale See chemical cleaning instructions Pg 16 Clean or replace filter Insufficient runs out of hot water at the faucet Thermostat setting too low Undersized boiler with no priority to domestic water he...

Страница 27: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 23 180 F Boiler Supply IBR Rating Condition HIGH OUTPUT UNITS 60 HO 80 HO 115 HO EXTRA HIGH OUTPUT UNITS 85 XHO 115 XHO...

Страница 28: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 24 Replacement Parts List...

Страница 29: ...ne of two time periods 1 LIMITED FIVE YEAR WARRANTY for five years as long as the original consumer purchaser owns the home residence in which the water heater is located 2 ADDITIONAL LIMITED WARRANTY...

Страница 30: ...characteristics LIMITATION OF WARRANTIES AND REMEDIES THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LI...

Страница 31: ......

Страница 32: ...Heat Flo Inc 15 Megan Ct P O Box 612 Uxbridge MA 01569 USA Phone 508 278 2400 Fax 508 278 2466 e mail sales heat flo com www heat flo com Providing Solutions through Superior Design...

Отзывы: