![Heat & Glo TRUE-36C Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/heat-and-glo/true-36c/true-36c_owners-manual_2115513045.webp)
45
Heat & Glo •
TRUE-36, TRUE-42, TRUE-50 • 2282-900 Rev. i •
4/13
12
12
Electrical Information
A. Wiring Requirements
NOTICE:
This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (IntelliFire
Plus
TM
ignition).
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT
wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
B. IntelliFire Plus
TM
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
TM
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA batteries
(not included) into the battery pack before use.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-
liFire Plus
TM
wireless controls be used for their features
and functionality with the IntelliFire Plus
TM
ignition sys-
tem.
Figure 12.1 IPI Wiring Diagram
LED CONTROL
TO JUNCTION
BOX (110V)
MODULE
I
S
FLAME
SENSE
IGNITER
RC300 4.5V DC
(AAA X 3)
TO JUNCTION
BOX 110VAC
AUX2 NOT USED
PROTECTIVE COVER INCLUDED
GROUND
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
BATTERY PACK
6V DC
FLAME
MODULATION
AUX300 MODULE
AUX 1
AUX 2
FRONT EMBER LIGHTING (X 3)
REAR ACCENT LIGHTING (X 2)
ORANGE
WHITE
BLACK/RED
BLACK/RED
Î