manualshive.com logo in svg
background image

Heat & Glo  •  TIARAP-BK-IPI, TIARAP-BR-IPI, TIARAP-CES-IPI Owner’s Manual   •  2344-981  •  5/14 

12

Figure 3.4  Control Module

Control Module Operation

1.  The control module has an ON/OFF/REMOTE selector 

switch that must be set.  See Figure 3.4. 

 

OFF Position:  Appliance will ignore all power inputs and 
will not respond to any commands from a wall switch or 
remote.  The unit should be in the OFF position during 
installation, service, battery installation, fuel conversion, 
and in the event that the control goes into LOCK-OUT 
mode as a result of an error code. 

 

ON Position:  Appliance will ignite and run continuously 
in the HI 

fl

 ame setting, with no adjustment in 

fl

 ame 

output.  This mode of operation is primarily used for 
initial installation or power outage operation with battery 
backup. 

  REMOTE Position:   Appliance will initiate commands 

from an optional wired wall switch and/or the wireless 
remote (RC100, RC200, RC300).

2.   If using the wired switch in the control cavity with the 

module in REMOTE mode, the 

fl

 ame output can be 

adjusted with the HI/LO selector switch on the module.  
See Figure 3.6.  Note that the 

fl

 ame HI/LO selector 

switch will become inactive once an optional remote 
control (RC200/RC300) is programmed to the control 
module. Note that the control module will always ignite 
the 

fi

 replace on HI and remain so for the initial 10 

seconds of operation.  If the HI/LO is switched to the 
LO position, the 

fl

 ame output will automatically drop to 

the lowest setting after the 

fl

 ame has been established 

for 10 sec.  After this 10 second period, the 

fl

 ame can 

be adjusted from HI to LO with the switch. 

3.  The control module has safety feature that automatically 

shuts down the 

fi

 replace after 9 hours of continuous 

operation without receiving a command from the RC300 
remote.  

4.  If you intend to use both the wired appliance switch and 

the RC300 remote control to operate your 

fi

 replace, the 

appliance   switch will override any commands given 
by the remote. 

5. 

Module Reset 

 

This module may lock-out under certain conditions.  
When this occurs, the appliance will not ignite or 
respond to commands. The module will go into 
lock-out mode by emitting three audible beeps, then 
continuously displaying a RED/GREEN error code at 
its status indicator LED.

•  Check battery tray.  Remove batteries if installed.  

Batteries should only be installed for use during power 
outages.  See Section H.

•  Locate the module selector switch.  (See Figure 3.6).
•  Set the module selector switch to the OFF position.
• Wait 

fi

 ve (5) minutes to allow possible accumulated 

gas to clear.

•  Set the module selector switch to ON or REMOTE 

position.

•  Start the appliance.

WARNING! Risk of Explosion! DO NOT

 press the mod-

ule reset switch more than one time within a 

fi

 ve minute 

time period. Gas may accumulate in 

fi

 rebox.  Call a quali-

fi

 ed service technician.

Nine Hour Safety Shutdown Feature

The appliance has a safety feature that automatically 
shuts down the 

fi

 replace after nine hours of continuous 

operation without receiving a command from the wall 
switch or optional remote. 

I. Detailed Component Operating Instruc-

tions - IntelliFire Plus

LP/NG GAS-TYPE 
SELECTOR SWITCH

WIRE LEAD FROM 
REGULATOR CONNECTS HERE

MODULE

Optional Fan Operation

If desired, a fan kit may be added.  Contact your dealer 
to order the correct fan kit. Heat management for the fan 
is discussed in Section 3.G.  Detailed instructions are in-
cluded with the fan kit.

Appliance ON/OFF

If an optional remote control or wall control is installed, 
it should be used to control the ON/OFF function of the 
appliance.  Follow instructions included with the installed 
control.

To operate the appliance without a wall control or remote 
control, use the ON/OFF switch located on the front panel 
of the control cavity of the appliance.  See Figure 3.5.

CAUTION! Risk of Electric Shock! 

Avoid touching wires 

and electrical components in appliance control cavity.

Содержание TIARAP-BK-IPI

Страница 1: ...ts for location of additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do if...

Страница 2: ...Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Appr...

Страница 3: ...rmation A Appliance Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifi...

Страница 4: ...te of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent autho...

Страница 5: ...SED WARRANTY SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interi...

Страница 6: ...NSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic gl...

Страница 7: ...children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on...

Страница 8: ...RNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed Figure 3 2 General Operating Parts GLASS ASSEMBLY SECTION 4 B FAN KIT SECTION 6 A CLEAR SPACE SECTION 3 A...

Страница 9: ...loor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE...

Страница 10: ...ion during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controlled by the...

Страница 11: ...control cavity of the appliance See Figure 3 3 for location 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur A complete wiring d...

Страница 12: ...e RC300 remote control to operate your fireplace the appliance switch will override any commands given by the remote 5 Module Reset This module may lock out under certain conditions When this occurs t...

Страница 13: ...by Glass Cleaning Seasonally Homeowner Remote Control Seasonally Venting Seasonally Gasket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection A...

Страница 14: ...emote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to prevent u...

Страница 15: ...tion when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operat...

Страница 16: ...e paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result of the c...

Страница 17: ...ltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4 volts rep...

Страница 18: ...d to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms set at lo...

Страница 19: ...n is purchased have it installed by a qualified service technician Section 3 discusses using the fan to manage the heat output Follow the instruc tions supplied with the fan kit to operate your fan Se...

Страница 20: ...ice Parts Beginning Manufacturing Date June 2014 Ending Manufacturing Date Active TIARAP IPI Part number list on following page Log Set Assembly Gas Stove DV 05 14 TIARAP CES IPI TIARAP BR IPI TIARAP...

Страница 21: ...0010BK TIARAP BR 476 0010PBR TIARAP CES 476 0010CES 5 Side Left or Right TIARAP BK 476 0020BK TIARAP BR 476 0020PBR TIARAP CES 476 0020CES 6 Grommet 2118 420 7 Pilot Shield 2344 103 8 Pilot Assembly...

Страница 22: ...s Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 25 1 Blower Shroud Top 2344 118 25 2 Relie...

Страница 23: ...consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 18 1 Battery Pack 2166 323 18 2 J...

Страница 24: ...____________________________________________ ________________________________________________________________________________ __________________________________________________________________________...

Отзывы: