Heat & Glo SLR-D Скачать руководство пользователя страница 48

48

Heat & Glo  •  SLR-D  •  2333-900 Rev. F  •  9/17

4.  Lift the valve assembly up and out to make necessary 

service or repair.

C.  Gas Connection

 •  Refer to Section 16 for location of gas line access in 

appliance.

•  Gas line may be run through knockout(s) provided.

•  The gap between supply piping and gas access hole may 

be caulked with caulk

 

with a minimum of 300 ºF continuous 

exposure rating or stuffed with non-combustible, unfaced 

insulation to prevent cold air infiltration.

•  Ensure that gas line does not come in contact with outer 

wrap of the appliance. Follow local codes.

•  Pipe incoming gas line into valve compartment.
• Connect incoming gas line to the 1/2 in. (13 mm) 

connection on manual shutoff valve.

WARNING! 

Risk of Fire or Explosion! 

Support control 

when attaching pipe to prevent bending gas line.

•  A small amount of air will be in the gas supply lines. 

WARNING! 

Risk of Fire or Explosion! 

Gas build-up dur-

ing line purge could ignite. 

•  Purge should be performed by 

qualified service 

technician

•  Ensure adequate ventilation. 

•  Ensure there are no ignition sources such as sparks 

or open flames.

Light the appliance. It will take a short time for air to purge 

from lines. When purging is complete the appliance will 

light and operate normally.

WARNING! 

Risk of Fire, Explosion or Asphyxiation! 

Check  all  fittings  and  connections  with  a  non-corrosive 

commercially available leak-check solution. 

DO NOT

 use 

open  flame.  Fittings  and  connections  could  have  loos

-

ened during shipping and handling.

WARNING! 

Risk of Fire! 

DO NOT

 change valve settings. 

This valve has been preset at the factory. 

D.  High Altitude Installations

NOTICE: 

If the heating value of the gas has been reduced, 

these rules do not apply. Check with your local gas utility 

or authorities having jurisdiction.

When installing above 2000 feet elevation:

•  In the USA: Reduce burner orifice 4% for each 1000 feet 

above 2000 feet.

•  In CANADA: Reduce burner orifice 10% for elevations 

between 2000 feet and 4500 feet. Above 4500 feet, 

consult local gas utility.

Valve Pressure Taps

The pressure taps are available through the front of the 

appliance. 

The decorative mesh front and fireplace glass 

assembly must be removed to gain access to the pressure 

taps.  See  Figure 11.5.

Figure 11.4.  Disconnect Gas Valve

Note:

 The manifold and inlet pressure tabs can be ac-

cessed from the front of the fireplace when valve assembly 

is installed.

Figure 11.5  Valve Pressure Taps and Remote Receiver Location

PRESSURE TAPS

OPTIONAL REMOTE 

RECEIVER

Note: 

Install the gas supply line in accordance with local 

codes, if any. If not, follow ANSI 223.1. Installation should 

be done by a qualified installer approved and/or licensed 

as required by the locality. (In the Commonwealth of 

Massachusetts installation must be performed by a 

licensed plumber or gas fitter).

Note: 

A listed (and Commonwealth of Massachusetts ap-

proved) 1/2 in. (13 mm) T-handle manual shut-off valve 

and flexible gas connector are connected to the 1/2 in. (13 

mm) control valve inlet. 

•  If substituting for these components, please consult 

local codes for compliance.

Содержание SLR-D

Страница 1: ...nly for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your buil...

Страница 2: ...utilise utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes codes if if any any if if not not follow follow ANSI ANSI Z223 1 Z223 1 in in the the USA USA or or CAN CGA CAN CGA B149 B149 installation installation codes codes Installer Installer l appareil l appareil se...

Страница 3: ...llation Considerations 16 C Tools and Supplies Needed 16 D Inspect Appliance and Components 16 5 Framing and Clearances A Selecting Appliance Location 17 B Constructing the Appliance Chase 18 C Clearances 19 D Mantel and Wall Projections 20 6 Termination Locations A Vent Termination Minimum Clearances 22 7 Vent Information and Diagrams A Approved Pipe 24 B Vent Table Key 24 C Use of Elbows 24 D Me...

Страница 4: ... Setup A Remove Fixed Glass Assembly 59 B Remove the Shipping Materials 59 C Clean the Appliance 59 D Accessories 59 E Glass Rock Media Kit 59 F Fixed Glass Assembly 61 G Install the Decorative Front 61 H Air Shutter Setting 61 15 Troubleshooting A IntelliFire Ignition System 62 16 Reference Materials A Appliance Dimension Diagram 64 B Vent Components Diagrams 65 C Service Parts 71 D Contact Infor...

Страница 5: ...original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The...

Страница 6: ... This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left...

Страница 7: ...s tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdiction When installing above 2000 feet elevation In the USA Redu...

Страница 8: ...ing appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizon tally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob serves carbon monoxide detectors and signage installed in accordance...

Страница 9: ...ols out of reach of children Never leave children alone near a hot fireplace whether operating or cooling down Teach children to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org safety information To prevent unintended operation when not using your fire place for an extended period of time summer...

Страница 10: ... install one For more information refer to the instructions supplied with your decorative door or front F Remote Controls Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if...

Страница 11: ...lean See installation and operating instruc tions accompanying appliance Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having flammable vapors away DO NOT operate the appliance with fixed glass assembly removed cracked or broken Replacement of the fixed glass assembly should be done by a licensed or qualified service person Immediately call your gas su...

Страница 12: ...should be cleaned within 3 to 4 hours of initial burning A non abrasive cleaner such as gas appliance glass cleaner may be nec essary See your dealer Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the fireplace Rock Media Kit There may...

Страница 13: ... you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fronts Frequency Annually By Homeowner Tools needed Protective gloves stable work surface Assess condition of screen and replace as necessary Inspect for scratches dents or other damage and repair as necessary Check that louvers are not blocked Vacuum and dust surfaces Remote Cont...

Страница 14: ...e all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Verify burner is properly secured and aligned with pilot or igniter Clean off burner top inspect for plugged ports corrosion or deterioration Re...

Страница 15: ...ENETRATION FRAMING SECTION 8 B VERTICAL TERMINATION CAP SECTION 10 H NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE SECTION 10 F STORM COLLAR SECTION 10 G VENT PIPE SECTIONS 7 and 8 CEILING FIRESTOP ON FLOOR OF ATTIC SECTION 8 C FRAMING HEADER SECTION 5 GAS LINE SECTION 11 WALL SWITCH FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 C ATTIC INSULATION SHIELD NOT SHOWN MUST BE ...

Страница 16: ...y C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Framing material Pliers Non corrosive leak check solution Hammer Phillips screwdriver magnetic Gloves Framing square Voltmeter Electric drill and bits 1 4 in magnetic Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver 1 2 ...

Страница 17: ...Actual installation may vary due to individual design preference 1 IN A E A B C TOP VENT ONE 900 ELBOW ALCOVE INSTALLATION D TOP VENT ONE 90 ELBOW B F Figure 5 1 Appliance Locations A B C D E F Inches 53 1 32 48 75 See Section D Figure 5 5 5 6 19 9 32 17 3 4 Millimeters 1347 1219 1905 490 451 Unlike many traditional single sided Heat Glo fireplaces the SLR D is recessed into surrounding framing Th...

Страница 18: ...ess To further prevent drafts the wall shield and ceiling fire stops should be caulked with caulk with a minimum of 300 ºF continuous exposure rating to seal gaps Gas line holes and other openings should be caulked with caulk with a minimum of 300 ºF continuous exposure rating or stuffed with unfaced insulation If the appliance is being installed on a cement surface a layer of plywood may be place...

Страница 19: ...pace may cause overheating and a fire C B D A Figure 5 2 Clearances to Combustibles H E MEASURE FROM TOP OF FIREPLACE OPENING I F J G Note Figure 5 2 shows the fireplace installed on the floor However this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained MINIMUM FRAMING DIMENSIONS A B C D E F G ...

Страница 20: ...MUM FIREPLACE OPENING See Dimension B on Appliance Dimension Diagram Figure 16 1 7 IN MINIMUM UNLIMITED FIREPLACE OPENING See Dimension B on Appliance Dimension Diagram Figure 16 1 Note For non combustible fireplace finish material marble stone etc specifications refer to Section 13 C Figure 5 7 Front Side Finishing Detail 1 IN FRAMING 1 2 IN FACTORY SUPPLIED NON COMBUSTIBLE BOARD NAILING TAB 14 I...

Страница 21: ...21 Heat Glo SLR D 2333 900 Rev F 9 17 3 1 2 IN 1 IN AIR SPACE NON COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 IN Figure 5 8 Non Combustible Zone ...

Страница 22: ...MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING Gas Wood or Fuel Oil Termination Cap B Gas Termination Cap A If using decorative cap cover s t...

Страница 23: ...ervice V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMAX 2 termination caps x QACTUAL Covered Alcove Applications Spaces open only on one s...

Страница 24: ...t diagrams were made using the following standards Pipe measurements are shown using the effective length of pipe see Figure 7 3 Measurements are made from the appliance outer wrap not from the standoffs Horizontal terminations are measured to the outside mounting surface flange of termination cap Vertical terminations are measured to bottom of termination cap Horizontal pipe installed level with ...

Страница 25: ...n ceiling firestops ALWAYS maintain specified clearances around venting and firestop systems Install wall shield and ceiling firestops as specified Failure to keep insulation or other material away from vent pipe may cause fire WARNING Note Use SLP Series components only Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figur...

Страница 26: ...ow 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 15 ft 4 6 m H1 H2 MAX 15 ft 4 6 m V H1 H2 MAX 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 17 CAUTION The SLP HRC SS termination cap is not approved for use with propane LP fuel May lead to elevated glass...

Страница 27: ...0 m 2 ft 610 mm 12 ft 3 7 m 3 ft 914 mm 14 ft 4 3 m H1 H2 MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H1 H2 cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 17 CAUTION The SLP HRC SS termination cap is not approved for use with propane L...

Страница 28: ...ALLED HORIZONTALLY Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 17 V Minimum H1 H2 H3 MAXIMUM SLR D NG ONLY 3 ft 914 mm 15 ft 4 6 m H1 H2 H3 MAX 15 ft 4 6 m V1 MAX 7 ft 2 1 m CAUTION The SLP HRC SS termination cap is not approved for use with propane LP fuel May lead to elevated glass temperature that may cause ...

Страница 29: ...iercing screws to secure vent restrictor to firebox heat shield See Figure 7 10 Exhaust restrictors are recommended for these vertically terminated products which have excessive draft Exhaust restrictors will compensate for high draft and restore vi sual flame height If the vent configuration has a total ver tical of 15 44 feet an exhaust restrictor may be needed The exhaust restrictor can be loca...

Страница 30: ...2 Minimum 90 Elbow 2 ft 610 mm 1 ft 152 mm 3 ft 914 mm 2 ft 457 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 1 m 15 ft 4 6 m H MAX 15 ft 4 6 m V1 V2 H MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 17 ...

Страница 31: ...mum V2 V1 V2 Minimum 90 Elbow 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 14 ft 4 3 m H MAX 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H1 H2 cannot exceed 40 ft 12 2 m Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 1...

Страница 32: ...ponents only Note There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installation see Figure 7 17 SLR D V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN 1 1 2 ft 457 mm 4 ft 1 2 m 4 ft 1 2 m 4 ft 1 2 m 3 1 2 ft 1 0 m V1 V2 V3 H1 H2 Maximum 40 ft 12 2 m Figure 7 13 V1 H1 V2 V3 H2 ...

Страница 33: ...hnologies recommends that NFI or CSIA certified professionals or technicians under the direction of certi fied professionals conduct a minimum of a NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney is properly secured EXHAUST VENT PIPE INLET AIR VENT PIPE Figure 7 ...

Страница 34: ...he DV 46DVA GCL adapter with three self tapping screws TOP VENT WARNING Risk of Fire Explosion or Asphyxiation Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance May impair safe operation of this appliance or other appliances connected to the flue Vent this appliance directly outside Use separate vent system for this appliance NOTICE To achie...

Страница 35: ...in venting direc tion and in any location where it is necessary to maintain the necessary clearance to combustibles A simple up and out installation Figure 7 17 requires only enough support to maintain the necessary clearance to combusti bles However the vent attachment point and the firestop location are considered to be supports Figure 7 17 Flex Vent Pipe Generic Fireplace Shown 3 in CLEARANCE T...

Страница 36: ...2 Wall Penetration Shows center of vent framing hole for top venting The center of the hole is one 1 in 25 4 mm above the center of the horizontal vent pipe Figure 8 1 Horizontal Venting Clearances To Combustible Materials A B 46 1 16 in 1170 mm 45 1 16 in 1145 mm A 10 in 10 in B DO NOT PACK WITH INSULATION OR OTHER MATERIAL B Wall Penetration Framing Combustible Wall Penetration Whenever a combus...

Страница 37: ...ating Figure 8 3 Installing Ceiling Firestop ATTIC ABOVE A PIPE SLP A 9 in 229 mm A Figure 8 4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING CEILING FIRESTOP INSTALLED ABOVE CEILING D Install Attic Insulation Shield WARNING Fire Risk DO NOT allow loose materials or insulation to touch vent Hearth Ho...

Страница 38: ...e left and right sides of the appliance Either one or two Heat Zone Gas Kits may be installed Only one Heat Zone Plus Kit may be installed See Figure 8 5 Remove the knockouts from the appliance with a tin snips Center the duct collar around the exposed hole and attach it to the appliance with 3 screws Note Do this BEFORE final positioning of the appliance Determine the location for the air registe...

Страница 39: ... GASKET Figure 9 2 Elbow Shield Shown Installed If venting with a 90 degree elbow directly off of the top of the appliance the elbow heat shield must be repositioned as shown in Figure 9 2 If not venting with a 90 degree elbow remove the elbow heat shield and discard by removing the two 1 4 in screws that secure the elbow heat shield to the top of the fireplace For all venting applications ensure ...

Страница 40: ... are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep nailing tabs flush with the framing Level the appliance from side to side and front to back Shim the appliance as necessary It is acceptable to use wood shims underneath the appliance Secure the appliance to the framing by using nails or screws through the nailing ...

Страница 41: ...ely fitted and locked into the preceding component Commercial Multi family Multi level exceeding two sto ries or High Rise Applications For Installation into a commercial multi family multi level exceeding two stories or high rise applications All outer pipe joints must be sealed with silicone with a minimum of 300 ºF continuous exposure rating including the slip section that connects directly to ...

Страница 42: ...e is not required All unit collar pipe slip section elbow and cap outer flues shall be sealed Maintain a 1 1 2 in 38 mm overlap between the slip section and the pipe section Secure the pipe and slip section with two screws no longer than 1 2 in 13 mm using the pilot holes in the slip section See Figure 10 4 C Secure the Vent Sections Vertical runs originating off the top of the appliance with no o...

Страница 43: ... ceiling and drill a small hole through the ceiling and roof at this point Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm larger than the support box outline Lower the support box through the hole in the roof until its bottom is...

Страница 44: ...HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 10 12 Figure 10 13 Assembling the Storm Collar Around the Pipe NOTICE Failure to properly caulk the roof flashing and pipe seams may permit entry of water Caulk the gap between the roof flashing and the outside diameter of the pipe Caulk the perimeter of the flashing where it contacts the roof surface See Figure 10 12 Caulk the overlap seam of an...

Страница 45: ...heat shields must extend through the entire wall thick ness DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap shown in Figure 10 16 Heat shields must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other section is factory attached to the cap See Figure 10 ...

Страница 46: ... cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1 and CAN CGA B149 installation codes and refer to Section 6 of this manual CAUTION Risk of Burns Local codes may require in stallation of a cap shield to prevent anything or anyone from touching the h...

Страница 47: ...bly and valve plate See Figure 11 1 The lower access cover panel is removable if finishing material has not been previously installed Figure 11 1 Cover Tray Removal MEDIA TRAY BASE PAN ASSEMBLY SCREWS PILOT BRACKET SCREWS Figure 11 2 Remove Valve Plate Screws 3 Set the valve bracket on the front lip of the firebox bot tom Turn off the ball valve Disconnect gas valve from the gas flex ball valve as...

Страница 48: ... could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdiction When installing above 2000 feet elevation In the USA Reduce burner orifice 4 ...

Страница 49: ...e 3 volt AC transformer into the appliance junction C Optional Accessories Requirements This appliance may be used with a wall switch wall mounted thermostat and or a remote control 12 Electrical Information Battery Pack Location Batteries are to be installed only when battery power is required Because of the limited accessibility to the valve cavity the battery pack and IPI control module must be...

Страница 50: ...junction box heat shield such that it is positioned over the junction box TRANSFORMER 3 VAC PLUG IN BLACK RED BATTERY PACK WIRE ASSEMBLY WIRES TO BROWN ORANGE GREEN VALVE WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS NOTE 1 Ignition module valve pilot and wall switch operate on 3 volts 120 VAC is required at junction box unless equipped w...

Страница 51: ...stible Materials Specification Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC shall be considered non combustible materials Setting the Firepla...

Страница 52: ...actory installed non combustible board See Figure 13 3 Note It is acceptable to use a silicone sealant with a minimum of 300 ºF continuous exposure rating to adhere drywall to lower cover panel Note Refer to Section 13 C regarding installation details associated with the Inside and Overlap Fit methods Do not drill or install screws which may penetrate the lower cover panel as this will restrict re...

Страница 53: ...stible board should be fastened to the framing with at least 1 1 4 in long screw fasteners located within 1 1 2 in from each corner and at no more than 12 inch intervals along the joint length The wall board joints should be finished with a Taping Coat followed by at least two subsequent Finish Coats of joint compound For the initial Taping Coat it is critical that a general purpose chemically har...

Страница 54: ...tions Acceptable on both sides of opening 3 FT MAXIMUM 6 IN MINIMUM FIREPLACE OPENING See Dimension B on Appliance Dimension Diagram Figure 16 1 7 IN MINIMUM UNLIMITED FIREPLACE OPENING See Dimension B on Appliance Dimension Diagram Figure 16 1 14 IN MIN 12 IN MAX 1 2 IN Thick Wall Sheathing MEASUREMENT FROM TOP OF FIREPLACE OPENING See Dimension T on Appliance Dimension Diagram Figure 16 1 Note F...

Страница 55: ...WN 1 1 2 IN ABOVE STANDOFF Overlap Requirement See Figure 13 9 Inside Fit requirement See Figure 13 10 and Figure 13 11 C Facing Material Facing and or finishing materials must not interfere with air flow through louvers or decorative fronts Facing and or finishing materials must never overhang into the glass opening Observe all clearances when applying combustible materials WARNING Risk of Fire D...

Страница 56: ...led tight to the finishing flanges and must not overlap any finish material Ensure that minimum clearances to non combustible fin ish materials meet the specifications in Figure 13 11 Non Combustible Finish Material 0 4 Inches Thick Bottom Joint 3 4 IN TON SLR 3 1 4 IN TON SLR 3 4 IN TON SLR Figure 13 11 Noncombustible Surface Finishing Material 0 4 Inch Thick Inside Fit Method Tonic Decorative Fr...

Страница 57: ...t See Section 13 C Overlap Fit Only See Section 13 C Figure 13 14 Dimensions of Tonic Decorative Front TONIC DECORATIVE FRONT TON SLR MARTINI DECORATIVE FRONT MAR SLR A B D C E F TONIC FRONT Table 1 Dimensions of Tonic Decorative Front A Top of decorative front to bottom of appliance 26 3 8 in 670 mm B Bottom of decorative front to bottom of appliance 6 7 8 in 175 mm C Inside dimension of decorati...

Страница 58: ...bottom of appliance 26 3 16 IN 665 mm B Bottom of decorative front to bottom of appliance 7 5 16 IN 185 mm C Outside dimension of decorative front width 46 3 16 IN 1172 mm D Outside dimension of decorative front height 18 7 8 IN 479 mm E Inside dimension decorative front width 40 1 4 IN 1022 mm F Inside dimension decorative front height 13 1 4 IN 337 mm A B C D E F ...

Страница 59: ...ass rock particles An easy method to clean the glass rock media is to empty the contents of the bag into a bucket and rinse thoroughly with a garden hose Allow the glass rock media to dry before installing into the fireplace Installation 1 Position rock media placement jig over pilot shield to prevent inadvertent glass rock media placement in front of pilot shield 2 Figure 14 1 shows the outline o...

Страница 60: ...DASHED LINES WARNING Risk of Fire DO NOT place glass rock me dia directly in front of the pilot assembly or between the burner tracks over the burner ports NOTICE Care should be taken to avoid placing glass rock media between the left right and back edges of the media tray and the firebox Blocking this gap may cause an undesirable flame appearance See Figure 14 4 BURNER TRACKS ...

Страница 61: ...ight of the fireplace 3 Use both index fingers to release spring latches See Figure 14 5 4 Allow glass to tilt forward Grasp glass on the upper right and left sides and lift glass up and out Replacing Fixed Glass Assembly 1 Locate glide tabs on lower left and right corners 2 Grasp glass on upper right and left sides and tilt bot tom of glass assembly toward fireplace 3 Allow of the bottom gasketin...

Страница 62: ...ation or wiring harness Remove and reinstall the wiring harness that plugs into module Verify there is a tight fit Verify pilot assembly wiring to module Re move and verify continuity of each wire in wiring harness Replace any damaged components c Improper wall switch wiring Verify that 110 120 VAC power is ON to junction box d Module not grounded Verify black ground wire from module wire harness ...

Страница 63: ...ice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod c Module is not grounded Verify module is securely grounded to metal chassis of appliance Verify that wire harness is firmly connected to the module d Damaged pilot assembly or contami nated flame sensing rod Verify...

Страница 64: ...VIEW FRONT VIEW RIGHT VIEW ELECTRICAL ACCESS A B C D E T U V L N Ø I J K M S R 1 INCH STANDOFF Figure 16 1 Appliance Dimensions Location Inches Millimeters L 37 3 4 959 M 16 3 4 425 N 6 5 8 168 O 39 3 4 1010 P 2 3 16 56 Q 6 152 R 17 1 4 438 S 18 1 4 464 T 25 7 8 657 U 9 3 4 248 V 51 1 2 1308 Location Inches Millimeters A 48 1219 B 43 1092 C 39 1 16 993 D 13 1 4 337 E 41 1042 F 3 9 16 90 G 6 7 8 17...

Страница 65: ...m DVP HSM B Extended Heat Shield Effective Height Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 6 51 152 SLP12A 2 12 51 305 SLP FLEX 2 24 610 SLP FLEX 3 36 914 SLP FLEX 5 60 1524 SLP FLEX 10 120 3048 SLP FLEX PIPE EFFECTIVE HEIGHT LENGTH SLP HVS Horizontal Pipe Support 10 7 8 in 276 mm 8 7 8 in 225 mm 1 1 2 in 38 mm SLP FS Ceiling Firestop...

Страница 66: ...al Ceiling Support Box Black 12 1 2 in 318 mm 12 in 305 mm SLP TVHW Vertical Termination Cap 13 in 330 mm 13 in 330 mm 1 5 16 in 34 mm SLP DCF BK Ceiling Firestop Black SLP WT BK Wall Thimble Black 14 7 16 in 367 mm 14 7 16 in 367 mm 2 5 16 in 59 mm SL 2DVP Adapter 3 15 16 in 101 mm 6 11 16 in 169 mm 8 in 203 mm 3 15 16 in 101 mm 3 13 16 in 97 mm 5 1 16 in 128 mm 17 7 8 IN 454 mm 7 3 8 IN 187 mm 1...

Страница 67: ...of 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3 1 8 in 4 3 4 in 79 mm 121mm Trap2 5 1 4 in 9...

Страница 68: ... IN 233 mm 4 1 2 IN 114 mm 16 11 16 IN 424 mm 13 5 8 346 mm 12 1 2 IN 318 mm 12 1 2 IN 318 mm 20 3 4 IN 527 mm 13 5 8 IN 346 mm PVI SLP B Power Vent Inline SLP LPC SLP Low Profile Cap Approved for use with PVI SLP B only Figure 16 5 PVI SLP B Vent Components Note Wire harnesses required to power the PVI SLP B connect to the appliance and are ordered separately from PVI SLP B Contact your dealer to...

Страница 69: ...5 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4 3 4 IN 121 mm 2 1 4 IN 57 mm 1 1 2 IN 38 mm 6 1 4 IN 159 mm Front View Top View Side View PVLP BEK Brick Kit B Vent Components Diagrams continued Note Wire harnesses required to power the PVLP SLP connect to the appliance and are ordered separately from PVLP SLP Contact your dealer to order Note The PVLP SLP requires a PV IPI CK be installed on this appliance ...

Страница 70: ... 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC Cap Brick Extension 13 7 8 in 352 mm 5 in 127 mm 11 7 8 in 302 mm Figure 16 7 Vent Components LINK DV30B Flex Liner Kit DV 46DVA GCL Coaxial Colinear Appliance Connector DVP 2SL Adapter COAXIAL to COLINEAR VENTING B Vent Components Diagrams continued ...

Страница 71: ...__________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Printed in U S A Copyright 2017 DO NOT DISCARD TH...

Отзывы: