18
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
K
C
A
L
F
I
B
G
E
D
J
J
G
A
F
C
A
H
M
N
Models
A
B
C
D
E
Min.
F
Min.
G
H
I
J
K
L
M
N
SL-750TRSFHHIPI
in.
45-1/2
42
64-3/8
See Section
D for Alcove
Installation
1
1/2
45-1/2
64-3/8
16-1/4
48-1/2
68-3/4
16-5/8
7-1/2
9
mm
1155
1067
1635
25
13
1155
1635
413
1232
1737
422
191
229